RENTAL INSPECTION - 202 SUMMIT AVE - 03/12/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 2ND
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24577
03/16/2026
04/20/2026
2026-00000078
$150.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
r
� 15D 24511
Waterloo Fire Rescue
Inspection Report
BLDG 202 Summit Ave - 202 Summit AVE, Waterloo IA 50701-2826
INSPECTION DETAILS
Inspection Date
03/12/2026
Lead Inspector
NATE BEUSELING
Inspection Type
2015 IPMC Rental Inspection REINSPEC710N
Other Inspectors
N/A
Shift
NIA
425 E. 3rd Street
Inspection Number
19699-R1
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 0 0 31
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
NATE BEUSELING
nate.beuseling@waterloo-ia.org
GENERAL NOTES
NATE BEUSELING - 03/12/2026 @ 10:43
Reinspection scheduled with April, no representative arrived in timeframe for Inspection, Reinspection fees applied
Reinspection Date
04/1012026
NATE BEUSELING - 01/02/2026 @ 11:19
Inspection was completed due to complaint by tenant, water damage needs to be investigated and repaired with permits and inspections all electrical
issues need to be investigated and repaired with proper permitting and inspections, could not inspect plumbing in kitchen due to not being able to
access due to garbage buildup in front of sink
NATE BEUSELING - 01/0212026 @ 11:19
Iowa Administrative Code 661-210.3(7) d. After June 30, 2021, a battery -powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery -powered smoke alarm must be powered by a nonremovable, non -replaceable battery that powers the alarm 'for at least ten
years. The battery requirements of this subrule do not apply to a fire alarm, smoke detector, smoke alarm, or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system; that uses a low -power, radio frequency wireless communication signal.
NATE BEUSELING - 01/0212026 @ 11:19
Re -inspection date is as posted on the inspection report. The rental unit's responsible person's shall contact prior to inspection date to set up time of re -
inspection. If all corrections are made before scheduled inspection, you ca n call to set up an earlier re -inspection. Please give the appropriate notices to
occupants of the unit/s. Owner or owner's agent must be present during the re -inspections. Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a $100.00 fee. Re -inspection fees may be assessed for re -inspections. Re -inspection fees start at :550, then $150,
and $250 for all subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspections.
NATE BEUSELING - 01/0212026 @ 11:19
Property Safety Inspector Nate Beuseling - nate.beuseling@waterloo-ia.org - Work: 319-291-4319 (48) - Cell: 319-464-5605
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 3/12/26, 10:44 AM 1 OF 11
Fortress Joy Date:
CHECKLISTS
NATE BEUSELING 03112/2026
GENERATED ON 3/12/26, 10:44 AM
2 OF 11
Reinspection
Statu
Fail
Fail
Fail
Fail
Fail
Fail
Code
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall be kept in
sound condition, good repair and weather tight.
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall be kept in
sound condition, good repair and weather tight.
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall be kept in
sound condition, good repair and weather tight.
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall be kept in
sound condition, good repair and weather tight.
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall he kept in
sound condition, good repair and weather tight.
2015 IPMC 304.15 - Doors
Exterior doors, door assemblies, operator systems if
provided, and hardware shall be maintained in good
condition. Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door. Locks on means
of egress doors shall be in accordance with Section 702.3.
Description
Location: Living room and dining room
Comments: One window opens all the rest are painted shut, every
window needs to be able to function as originally designed to do
Location: Kitchen
Comments: Kitchen window painted shut shall be corrected
Location: Bedroom 1 upstairs on left
Comments: One window functions the other window :s painted shut
shall be restored to original functionality
Location: Bedroom 2 upstairs on right furthest from stairs
Comments: Window broken, other painted shut, shall be repaired and
restored to normal functionality
Location: Bedroom 3 upstairs right by stairwell
Comments: NO windows working shall be restored to normal
functionality
Location: Stairwell to basement
Comments: Backdoor not weather tight shall be repaired
GENERATED ON 3/12/26, 10:44 AM
3 OF 11
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Location: Living room
Comments: small hole in drywall near heat register by front door
shall be repaired
Location: Living room
Comments: Register vent not secured to wall properly shall be
corrected
GENERATED ON 3/12/26, 10:44 AM
4 OF 11
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Location: Kitchen
Comments: Kitchen ceiling shows signs of water damage and leaking
water, shall be investigated to find cause and repaireu accordingly
Location: Basement
Comments: Holes in foundation allowing dirt to come in shall be
repaired and made weather tight
GENERATED ON 3/12/26, 10:44 AM
5 OF 11
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Location: Bedroom one upstairs on left
Comments: register pulled away from wall shall be secured
Location: Basement floor
Comments: Concrete broken in spots shall be repaired
GENERATED ON 3/12/26, 10:44 AM 6 OF 11
Fail
Fail
Fail
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 309.2 - Owner
The owner of any structure shall be responsible for pest
elimination within the structure prior to renting or leasing the
structure.
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1- General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
Teaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
Location: Basement stairwell
Comments: hole in wall patched in with plywood shall be repaired
and secured
Location: Property
Comments: Mice and other bugs noted to be in house pest
elimination and making property weather tight is a must
Location: Main floor bathroom
Comments: Shower head is loose shall be tightened
Location: Main floor bathroom
Comments: Toilet flap sticks making toilet run shall be corrected
Location: bathroom 2 upstairs
Comments: Toilet loose to floor shall be secured
GENERATED ON 3/12/26, 10:44 AM 7 OF 11
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1- General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Location: Bathroom 2 upstairs
Comments: Toilet leaks onto floor shall be corrected
Location: Bathroom 2 upstairs
Comments: shower fixtures loose shall be corrected
Location: Basement
Comments: Water heater not plumbed properly cannot have plastic
lines running within 18 inches of waterheater
Location: Basement
Comments: Old water heater shall be removed
Location: Kitchen
Comments: Outlet to the left of the stove did not test properly
Location: Main level bathroom
Comments: when GCFI outlet is tested it turns lights off to bathroom,
that shall be corrected and shall test properly at reinspection
GENERATED ON 3/12/26, 10:44 AM 8 of 11
Fail
FailF�
Fail
L.J
Fail
Fail
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not Tess than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Location: Bathroom 2 upstairs
Comments: GFCI outlet does not test properly shall be corrected
Location: Bedroom 2 upstairs furthest from stairs
Comments: Outlets read hot neutral reversed shall be corrected
Location: Living room/dining room
Comments: Smoke detector not functioning and or was taken down
shall be replaced
Location: Bedroom one off kitchen main floor
Comments: Missing smoke detector
Location: Bedroom 1 upstairs on left
Comments: no smoke detector in room
GENERATED ON 3/12/26, 10:44 AM 9 OF 11
Fail
Fail
Fail
2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
2021 IRC R315.3 - Carbon Monoxide Detection: Location
Carbon monoxide alarms in dwelling units shall be installed
outside of each separate sleeping area in the immediate
vicinity of the bedrooms. Where a fuel -burning appliance is
located within bedroom or its attached bathroom, a carbon
monoxide alarm shall be installed within the bedroom.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Location: Bedroom 3 upstairs to right off of stairs
Comments: Missing smoke detector
Location: Bedroom 1 off of kitchen main floor
Comments: No CO detector outside of sleeping room
Location: Basement
Comments: Fuse box in basement has sparking reaction to a breaker
being flipped shall be investigated and repaired
GENERATED ON 3/12/26, 10:44 AM