Loading...
HomeMy WebLinkAbout444 BRATNOBER ST'III 1011111 •1111 11 � 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/16/2026 04/20/2026 2026-00000079 $250.00 Customer #: 24577 NJI-II-L-Cl HOLDINGS 1309 COFFEEN AVE SUITE 1200 SHERIDAN, WY 82801 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 444 BRATNOBER ST - 03/12/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24577 03/16/2026 04/20/2026 2026-00000079 $250.00 Less Prepayment Total Due —> City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 316=3 245�1 Waterloo Fire Rescue Inspection Report 425 E. 3rd Street BLDG 444 Bratnober St. - 444 Bratnober ST, Waterloo IA 50703-3610 INSPECTION DETAILS Inspection Date 03112/2026 Lead Inspector NATE BEUSELING Inspection Type Rental Inspection (REINSPECTION ) Other Inspectors N/A Inspection Number 18388-R2 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 00 Passed codes NEXT STEPS 19 Failed codes Please direct questions about your Inspection to: NATE BEUSELING nate.beuseling@waterloo-ia.org GENERAL NOTES Reinspection Date 04/1012026 NATE BEUSELING - 0311212026 @ 10:36 Inspection scheduled for 3-12-2026 with April, no representative met at arranged times waited at location for 10 min and moved on, Reinspection fees applied NATE BEUSELING - 01/2012026 @ 09:28 Property Safety Inspector - nate.beuseling@waterloo-ia.org - Work: 319-291-4319 (#8) - Cell: 319-464-5605 NATE BEUSELING - 01/2012026 @ 09:28 Re -inspection date is as posted on the inspection report. The rental unit's responsible personls shall contact prior to inspection date to set up time of re - inspection. If all corrections are made before scheduled inspection, you can call to set up an earlier re -inspection. Please give the appropriate notices to occupants of the unit/s. Owner or owner's agent must be present during the re -inspections. Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a $100.00 fee. Re -inspection fees may be assessed for re -inspections. Re -inspection fees start at 550, then $150, and $250 for all subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspections. NATE BEUSELING - 01/20/2026 @ 09:28 Iowa Administrative Code 661-210.3(7) d. After June 30, 2021, a battery -powered smoke alarm listed in accordance with UL 217 that is newly installed or replaces an existing battery -powered smoke alarm must be powered by a nonremovable, non -replaceable battery that powers the alarm for at least ten years. The battery requirements of this subrule do not apply to a fire alarm, smoke detector, smoke alarm, or ancillary component that is electronically connected as a part of a centrally monitored or supervised alarm system; that uses a low -power, radio frequency wireless communication signal. NATE BEUSELING - 01/2012026 @ 09:28 All structural repairs, water heater replacement, furnace replacement and major electrical repairs require appropriate permits and inspections. NATE BEUSELING - 01/2012026 @ 09:28 Reinspection on 1-20-2026 ownership representative not present fees will be applied SIGNATURES Contact signature Inspector signature GENERATED ON 3/12/26, 10:37 AM 1 OF 9 No signature Report completed post inspection Fortress Joy Date: CHECKLISTS GENERATED ON 3/12/26, 10:37 AM 2 OF 9 Reinspection Status Code Fail 1010.2 - Door operations. 0 Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Fail O Fail Q R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Description Location: Back storm door Comments: Storm door does not shut and latch Location: Eve spouts Comments: Eve spouts are required to be in place to allow water to flow away from the buildings foundation, all eve spouts to be repaired or extended Location: Back porch Comments: Porch area with 4 steps or more requires hand rail to bottom step GENERATED ON 3/12/26, 10:37 AM 3 OF 9 Fail Fail R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Location: Back Porch Comments: Missing Railing on back porch, needs secured or replaced Location: Siding Comments: Siding on the house pulling away GENERATED ON 3/12/26, 16:37 AM 4 OF 9 Fail Fail Fail R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) R5 - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Location: Exterior of residence Comments: Residence shall be cleared of vegetation Location: Back door of house Comments: Weather stripping has seperated, needs replaced or resecured Location: Kitchen door to basement and back door Comments: Missing door knob GENERATED ON 3/12/26, 10:37 AM 5 OF 9 Fail O Fail O Fail O R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Location: Living room Comments: South window missing knob to open window, needs replaced Location: Living Room Comments: East window fails to open Location: Dining room Comments: damage to wall by register GENERATED ON 3/12/26, 10:37 AM 6 OF 9 Fail 0 Fail O Fail O Fail O R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Location: Kitchen Comments: Sliding doors on countertop off tracks needs repaired Location: Kitchen Comments: tears in flooring repair or replace Location: Basement Comments: cracks in foundation allowing air and moisture into the basement, needs sealant applied Location: Kitchen Comments: roaches found in and around cupboards mitigate and resolve GENERATED ON 3/12/26, 10:37 AM 7 OF 9 Fail Fail 0 Fail Cx2) Fail 0 R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) R6.D. - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a GFCI. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle shall have GFCI protection. All receptacles shall have the appropriate faceplate cover. (IPMC 605.2) Location: basement Comments: mold like substance present in basement, mitigation and removal required Location: Kitchen Comments: stove not working due to gas leak, replace equipment Location: Bathroom Comments: Exhaust fan in bathroom weak and needs to be replaced Location: Unit Comments: 3 unapproved adapters plugged into receptacles, tenant needs to remove GENERATED ON 3/12/26, 10:37 AM 8 OF 9 Statement of Fees FEE Invoice Date NIA Invoice Number NIA Inspection Fee Date Paid Amount Paid $250.00 Check Number Transaction Number NIA NIA GENERATED ON 3/12/26, 10:37 AM 9 OF 9