Loading...
HomeMy WebLinkAbout2808 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/20/2026 04/24/2026 2026-00000398 $80.00 Customer #: 21329 MAID -RITE 2808 UNIVERSITY AV WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2808 UNIVERSITY AVE - 03/17/2026 FOR BILLING INQUIRY: (319)291-4323 Description Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 21329 LUNG DATE DUE DATE INVOICE # CIIARGE 03/20/2026 04/24/2026 2026-00000398 City of Waterloo Less Prepayment Total Due —* $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of AR) 24g3Co Waterloo Fire Rescue Inspection Report Maid -Rite Diner - 2808 University AVE, BLDG 2808 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 03/17/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 21223 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION G 44 Passed codes NEXT STEPS 0 10 Failed codes 25 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/17/2026 @ 11:49 • $80 annual inspection fee BRAD BALDWIN - 03/17/2026 @ 11:52 Kitchen hood exhaust cleaning and hood suppression system inspection due in April 2026 BRAD BALDWIN - 03/17/2026 @ 11:52 Fire extinguishers due annually serviced in April 2026 BRAD BALDWIN - 03/1712026 @ 12:24 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/16/2026 BRAD BALDWIN - 03/17/2026 @ 12:24 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 03/17/2026 @ 12:24 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection RIT Chris Kolling (2026) Date: BRAD BALDWIN 03/17/2026 GENERATED ON 3/17/26, 12:34 PM 1 OF 8 CHECKLISTS GENERATED ON 3/17/26, 12:34 PM 2 OF 8 Additional Codes Status Corse Fail 102.4 - Application of budding code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. (11lu Intertek_, SBvz049:4 Description Location: Air conditioner unit (west side) Comments: Licensed mechanical contractor shall obtain permit and inspection for A/C installed without permit. DAIMN COMF'CiRt I[C HNCit�c.ETiAS� l9OOi RERM�ER RG WAtLER. TY 51 AC ASXNMNi1AP APRASE vaLiiiS 21k114' LiRA FOR MAX FORE AMPS M Ai: PS MA% CACUM C�0.WBREAt' ROAD DELAY FOE OR HACK 4t BPEARENRE NW. LIAL,At AMPS as 0.g. Iri VAN MOT OR PLA 23 LnA COMARE SSOR ALA 2i' SHORT CIRCUR CURRE MI SAA Ala SVAMAtTRICAL, PAW kt MAa(IMUM ALLOWABLE PRESSURF PS* t . ,. IMPS} �t t}t'�i ACTOR', CRAROE 02. (KO} R4S0 f S fa. re Eat PRESSURE IG RANI S7,Y VJ+1kt;Ih.0 >n•ADVE.R1t.. M} wA...Q ,0DVERTCNIA, . If' RA PART Location: Water heater Comments: Licensed plumbing contractor shall obtain permit and inspection of water heater (Manufactured October 2025) installed without permit. GENERATED ON 3/17/26, 12:34 PM 3 OF 8 Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Fail 610.1.1 - Installation. Clothes dryer exhaust duct systems shall be installed in accordance with the International Mechanical Code or the International Fuel Gas Code , and the manufacturer's installation instructions. Location: Top of basement stairs Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Basement laundry dryer vent Comments: Remove all screws in dryer vent piping and replace all piping that previously screwed together. All dryer vent piping connections shall be made per manufacturers guidelines. Annual cleaning of vent piping from the appliance to the exterior shall be documented, kept and provided to inspector at time of request. GENERATED ON 3/17/26, 12:34 PM 4 OF 8 Emergency Equipment Status Code Fail Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Description Location: North dining exit Comments: Repair or replace emergency egress Tight that failed to illuminate during test. Lights shall be directed downwards to illuminate path of exit. Location: South dining exit Comments: Repair or replace egress lighting that failed to illuminate during test. Location: West exit by office Comments: Repair or replace egress lighting that failed to illuminate during test. GENERATED ON 3/17/26, 12:34 PM 5 OF 8 Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Light fixture at top of basement stairs Comments: Provide knockout plug to opening in bottom of box GENERATED ON 3/17/26, 12.:34 PM 6 OF 8 Fail Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4.1- Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Location: Electric panel closet Comments: Remove obstructions (boxes) impeding 3E," clear access space in front of electric panels. Location: Electric panel closet Comments: Install permanent signage "Electrical Room" on door for firefighters. Laminated paper will not be accepted. GENERATED ON 3/17/26, 12:34 PM 7 OF B Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/17/26, 12:34 PM 8 OF 8