Loading...
HomeMy WebLinkAbout2313 LOGAN AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/20/2026 04/24/2026 2026-00000392 $80.00 Customer #: 24067 GREENLEAF TOBACCO AND E-CIGS 1503 E SAN MARNAN DR SUITE C WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2313 LOGAN AVE - 03/18/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 24067 BILLING DATE 03/20/2026 DUE DATE 04/24/2026 INVOICE # 2026-00000392 CHARGES $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 1 Waterloo Fire Rescue Inspection Report Greenleaf Vape & Tobacco - 2313 Logan AVE, BLDG 2313 Logan Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 03/18/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) $bp 24ocs1 Other lnspectors NIA 425 E. 3rd Street Inspection Number 21242 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 032 Passed codes NEXT STEPS 14 Failed codes 36 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/1812026 @ 14:59 • $80 annual inspection fee BRAD BALDWIN - 03/19/2026 @ 08:42 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN - 03/19/2026 @ 09:05 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (45) - Cell: 319-230-1224 Reinspection Date 04/1712026 BRAD BALDWIN - 03119/2026 @ 09:05 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 03/19/2026 @ 09:05 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection MO (2026) Date: BRAD BALDWIN 03/19/2026 CHECKLISTS GENERATED ON 3/19/26, 9:08 AM 1 OF 9 Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Description Location: Front exit door Comments: Repair door to open without special force, door shall open with less than 151bs of force. GENERATED ON 3/19/26, 9:08 AM 2 OF 9 Additional Codes Status t'orie Fail Fail Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Description Location: Cigar room Comments: Building and electrical permits and inspections shall be obtained for cigar room built without permits. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 308.1.5 - Location near combustibles. Open flames such as from candles, lanterns, kerosene heaters and gas -fired heaters shall not be located on or near decorative material or similar combustible materials. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Water heater Comments: Licensed plumbing contractor shall obtain permit and inspection of water heater installed without permit. Location: Burning incense Comments: Burning of incense or candles is prohibited. Incense was noted burning during 3118126 inspection, stop all burn ng immediately. Location: Window LED lighting Comments: Provide documentation of proper listing and use of listing of lighting. Description Location: Front exit Comments: Repair or replace exit sign and lights that failed to illuminate during test. GENERATED ON 3/19/26, 9:08 AM 3 OF 9 Electrical Safety Sloths Code Fail Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Display cases near front wall Comments: Provide further information to inspector of nature of white cords extending from under display cases. If extension cords, remove. Location: Front window above fridge Comments: Properly mount power strip to avoid hanging by wires, Location: Front wall Comments: Remove extension cord plugged to power strip. Power strip shall be properly mounted to wall to avoid hanging by wires and plugged directly to outlet. GENERATED ON 3/19/26, 9:08 AM 40F 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front window Comments: Remove extension cord plugged to power strip GENERATED ON 3/19/26, 9:08 AM 5 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front wall behind display cases Comments: Remove white extension cord taped to floor. Cords running across walkway shall be protected by listed floor cord protector. GENERATED ON 3/19/26, 9:08 AM 6 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind counter below register counter Comments: Provide further information regarding use of white cord extending from below cabinet plugged to power strip. GENERATED ON 3/19/26, 9:08 AM 7 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Portable Fire Extingusihers Co Fail 906.5 - Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will have ready access and be immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Location: Behind register, cigarette shelving Comments: Remove white cord extending through above ceiling. Description Location: Below register counter Comments: Fire extinguisher shall be relocated to a conspicuous location. Currently covered by bags and hidden. GENERATED ON 3/19/26, 9:08 AM 8 OF 9 rO FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 3/19/26, 9:08 AM 9 OF 9