COMMERCIAL INSPECTION - 2311 LOGAN AVE - 03/18/2026
FOR BILLING INQUIRY: (319)291-4323 —1
Description ..
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
20390
03/20/2026
04/24/2026
2026-00000393
$80.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
/ tab 20390
Waterloo Fire Rescue
Inspection Report
Subway - 2311 Logan AVE, BLDG 2311 Logan Ave, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
03/18/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
other Inspectors
N/A
425 E. 3rd Street
inspection Number
8005
Shift Station Unit
NIA N/A NIA
SUMMARY OF INSPECTION
035 5
Passed codes Failed codes
NEXT STEPS
35
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 03/18/2026 @ 12:37
• $80 annual inspection fee
BRAD BALDWIN - 03/1812026 @ 14:50
Fire extinguisher due annually serviced in February 2026
BRAD BALDWIN - 03/1812026 @ 14:54
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224
BRAD BALDWIN - 03/1812026 @ 14:54
Reinspection Date
04/17/2026
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. ****"Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Rob Pruitt (2026) Date: BRAD BALDWIN 03/18/2026
CHECKLISTS
GENERATED ON 3/18126, 2:56 PM 1 OF 5
Means of Egress
Status Code
Fail
1010.1.3 - Door opening force Forces to unlatch and open
doors.
The force for pushing or pulling open interior swinging
egress doors, other than fire doors, shall not exceed 5
pounds (22 N). These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full -open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch -pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full -open position when
subjected to not more than a 15-pound (67 N) force.
Additional Codes
Code
Fail
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Description
Location: South exit door
Comments: Door catches during opening, repair to open without
obstruction.
Description
Location: Water heater
Comments: Water heater missing pressure relief valve piping shall be
corrected.
GENERATED ON 3/18/26, 2:56 PM
2 OF 5
Fire Service Features
Status Code
Fail
505.1 - Address identification.
New and existing buildings shall be provided with approved
address identification. The address identification shall be
legible and placed in a position that is visible from the street
or road fronting the property. Address identification
characters shall contrast with their background. Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out. Each character shall be not
less than 4 niches (102 mm) high with a minimum stroke
width of 1/2 inch (12.7 mm). Where required by the fire code
official, address identification shall be provided in additional
approved locations to facilitate emergency response. Where
access is by means of a private road and the building cannot
be viewed from the public way, a monument, pole or other
sign or means shall be used to identify the structure. Address
identification shall be maintained.
Description
Location: Front of budding
Comments: Install address identifying numbers in contrast with the
building legible from the road for emergency services.
GENERATED ON 3/16/26, 2:56 PM
3 OF 5
Electrical Safety
a:.iti15 Code
Fail
Fail
603.4 - Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Description
Location: Electric panel
Comments: Remove storage obstructing clear path of access to
panel. Maintain 36" clearance in front of panel at all times.
Location: Near back hand wash sink
Comments: Remove green extension cord in corner extending above
drop ceiling.
GENERATED ON 3/18/26, 2:56 PM
4 OF 5
Statement of Fees
FEE
Invoice Date inspection Fee
NIA $80.00
Date Paid Amount Paid
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 3/18/26, 2:56 PM
5 OP 5
-