Loading...
HomeMy WebLinkAbout3005 KIMBALL AVECustomer #: 8099 PAPA MURPHY'S 3005 KIMBALL AV WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/20/2026 04/24/2026 2026-00000395 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3005 KIMBALL AVE - 03/17/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 8099 03/20/2026 04/24/2026 2026-00000395 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. $80 Waterloo Fire Rescue Inspection Report Papa Murphy's Pizza - 3005 Kimball AVE, BLDG 3005 Kimball Ave, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 03/17/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other lnspectors NIA Shift N/A 425 E. 3rd Street Inspection Number 1324 Station Unit N/A N/A SUMMARY OF INSPECTION 0 33 Passed codes NEXT STEPS ® 6 Failed codes 36 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/18/2026 @ 09:07 • S80 annual inspection fee BRAD BALDWIN - 03/18/2026 @ 09:18 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 03/1812026 @ 09:19 Reinspection Date 04/16/2026 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hows for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****'Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Chris Miller Date: CHECKLISTS BRAD BALDWIN 03/18/2026 GENERATED ON 3/18/26, 9:20 AM 1 OF 5 Means of Egress Status Fail code Description 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. General Housekeeping st<�iu.s Coc:.- Fail 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Location: Back exit Comments: Remove pallet of crust mix from path of access to exit. Maintain clear path to exit at all times. Description Location: Water heater Comments: Remove all combustible material (including rags & boxes) within 36" of water heater. Maintain proper clearance at all times. GENERATED ON 3/18/26, 9:20 AM 2 OF 5 Additional Codes Status Code Fail Fail 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 610.1.1 - Installation. Clothes dryer exhaust duct systems shall be installed in accordance with the International Mechanical Code or the International Fuel Gas Code , and the manufacturer&#039;s installation instructions. Description Location: Hobart mixer Comments: Licensed electrical contractor shall repair unprotected wires. Retain copy of receipt of work completed to provide for inspector. Location: Clothes dryer Comments: Laundry dryer vent installed improperly. Licensed mechanical contractor shall install dryer vent piping to the exterior by obtaining permit and inspection. Dryer vent shall be cleaned from the appliance to the exterior annually, maintain records of cleaning to provide to inspector. GENERATED ON 3/16/26, 9:20 AM 3 OF 5 Electrical Safety Staatc+•<, Code Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Portable Fire Extingusihers Status Fail Description Location: Under counter below register Comments: Remove white multi -plug extension cord. Code Description 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: All extinguishers Comments: Provide annual service to extinguishers, last recorded service completed in March 2023 GENERATED ON 3/18/26, 9:20 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/16/26, 9:20 AM 5 OF 5