Loading...
HomeMy WebLinkAbout3657 KIMBALL AVECustomer #: 5995 ARBY'S 3657 KIMBALL AV WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE# TOTAL DUE 03/20/2026 04/24/2026 2026-00000387 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3657 KIMBALL AVE - 03/17/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 5995 BILLING DATE 03/20/2026 DUE DATE 04/24/2026 INVOICE # 2026-00000387 CHARGES $80.00 Less Prepayment Total Due --* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Vato 5cp5 Waterloo Fire Rescue Inspection Report Arby's - 3657 Kimball AVE, BLDG 3657 Kimball Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 03117/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 3907 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 0 44 Passed codes NEXT STEPS `J 8 Failed codes 25 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/17/2026 @ 15:11 • $80 annual inspection fee BRAD BALDWIN - 03/18/2026 @ 07:48 Fire extinguishers due annually serviced in February 2027 BRAD BALDWIN - 03/18/2026 @ 08:21 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 03/18/2026 @ 08:22 Reinspection Date 04/16/2026 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Corporate email CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 03/1812026 GENERATED ON 3/18/26, 8:23 AM 1 OF 5 Additional Codes Status Code Description Fail 102.4 - Application of building code. CDThe design and construction of new structures shall comply Location: Water heater with the International Building Code , and any alterations, Comments: Licensed plumbing contractor shall obtain permit and additions, changes in use or changes in structures required inspection of water heater installed without permit. by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Location: HVAC permit Comments: Contractor (Brecke) shall obtain inspection of work completed, see attachment of permit. 42014.4 Coot %IC. 000 4.724201200..1 Location: Kitchen behind ice cream machine Comments: Licensed electrical contractor shall obtain permit and inspection to repair hazardous wiring condition. GENERATED ON 3/18/26, 8:23 AM 2 OF 5 Fail 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mglm3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: Kitchen fryers Comments: Fryers shall be under Type 1 hood with at least a 6" overlap and protected by fire suppression system. Move fryers under hood. GENERATED ON 3/18/26, 8:23 AM 3 OF 5 Fire Service Features Status Code Fail 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 112 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Commercial Cooking Hood Suppression System Status Fail 0 Fail 0 Code 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSI/IKECA C10. Description Location: West side (facing Kimball Ave) Comments: Install address identifying numbers in contrast to the building legible from the road. Description Location: Outlet in office Comments: Provide missing cover to outlet Description Location: Kitchen hood suppression system Comments: Contractor shall upload report of suppression system inspection to Compliance Engine including deficiencies corrected. Currently 24 days past due for report. "Hawkeye Fire" tagged serviced February 2026. Location: Kitchen fryer cabinet and surrounding Comments: Clean excess grease. GENERATED ON 3/18/26, 8:23 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 3/18/26, 8:23 AM 5 OF 5