HomeMy WebLinkAbout132 LOBDELL RDINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
03/20/2026
04/24/2026
2026-00000083
$250.00
Customer #: 24800
DON AND LYNETTE REINHOLDT
P.O. BOX 204
POCAHONTAS, IA 50574
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 132 LOBDELL RD - 03/11/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 3RD
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CIIARGES
24800
03/20/2026
04/24/2026
2026-00000083
$250.00
Less Prepayment
Total Due —�
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
ST-bp
D-tOO
Waterloo Fire Rescue
Inspection Report
132 Lobdell RD, Waterloo IA 50701-1102
INSPECTION DETAILS
425 E. 3rd Street
Inspection Date Inspection Type Inspection Number
03111/2026 Rental Inspection t REINSPECTION ) 16444-R9
Lead Inspector
NATE BEUSELING
Other Inspectors
NIA
Shift Station Unit
NIA
NIA N/A
SUMMARY OF INSPECTION
0 0 0 1 0 5
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
NATE BEUSELING
nate.beuseling@waterloo-ia.org
GENERAL NOTES
BARRY STRATTON - 02/12/2026 @ 06:59
Reinspection Date
04/08/2026
Plumbing details: Several corrections noted during inspection, a licensed plumbing contractor shall obtain proper permitslinspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Main floor bathroom sink drain, flexible drainage piping shall be replaced. (2) Water heater
installed without permitlinspection also missing approved PT tube. (3) Mechanical room sink drainagelvent piping installed not to plumbi -tg code shall be
corrected. (4) Laundry drainagelvent piping installed not to plumbing code shall be corrected. S-trap in basement needs removed. Have licensed plumber
make corrections.
BARRY STRATTON - 02/12/2026 @ 06:59
Electrical details: Several corrections noted during inspection, a licensed electrical contractor shall obtain proper permits/inspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Several open electrical boxes noted in basement without covers. Wires not landed in
boxes. (2) Lighting fixture noted in basement stoop unfixed, laying on shelf. (3) Electrical serving furnace, water heater & laundry installed without
permits/inspections. (4) Outlets/switches missing appropriate covers. (5) main floor SW bedroom, outlet below window failed tester due to "open
ground". (6) Loose wiring noted in basement shall be stapled. (7) Service mast tie down cable connected to chain, nailed to wood post shall be corrected.
BARRY STRATTON - 0211212026 @ 06:59
-Re-inspection date is as posted on the inspection report given, the rental unit's responsible personls shall reach out prior to set time of that re -
inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Appropriate notices shall be given
to occupants of the unit's. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the
inspection will result in a $100 fee. *****Re inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all
subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection.
BARRY STRATTON - 02/12/2026 @ 06:59
No permits have been obtained for the required corrections noted from previous inspectors reports.
BARRY STRATTON - 02/12/2026 @ 06:59
Need current 2026 rental registration for listed address.
SIGNATURES
Contact signature Inspector signature
GENERATED ON 3/18/26, 1:12 PM 1 OF 5
No signature
Report completed post inspection
Don Reinholdt Date:
CHECKLISTS
NATE BEUSELING 03118/2026
GENERATED ON 3/18/26, 1:12 PM
2 OF 5
Reinspection
Status Code
Fail
Fail
Fail
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Description
Location: Several electrical deficiencies
Comments: See notes for further details
Location: Furnace
Comments: Furnace installed without permit & inspection shall be
corrected. Licensed HVAC contractor shall obtain proper
permitslinspections to correct any deficiencies.
Location: Main floor bathroom
Comments: Shower walls not water -tight shall be corrected.
Looselflaking paint on wall surfaces shall he corrected.
Location: Several plumbing issues
Comments: See notes for further details.
GENERATED ON 3/18/26, 1:12 PM
3 OF 5
Fail R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Mechanical room floor drain
Comments: Drain cover obstructed shall be cleared to allow flow of
drainage.
GENERATED ON 3/18/26, 7.:12 PM 4 OF 5