Loading...
HomeMy WebLinkAbout620 COMMERCIAL STWA I OIL 11 IRO 1 � I I� • INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/27/2026 05/01/2026 2026-00000406 $80.00 Customer #: 24939 LUSTRE EVENT VENUE 620 COMMERCIAL ST WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS DCOMMERCIAL INSPECTION - 620 COMMERCIAL ST - 03/19/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE CHARGES 24939 03/27/2026 05/01/2026 2026-00000406 $80.00 Less Prepayment Total Due — City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. k 8d 2ya3q Waterloo Fire Rescue Inspection Report Lustre Event Venue - 620 Commerical ST, BLDG 620 Commerical St, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 03/19/2026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 1015 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 43 0 7 Passed codes NEXT STEPS Failed codes 25 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/20/2026 @ 14:43 • $80 annual inspection fee BRAD BALDWIN - 03/2012026 @ 14:43 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/1012026 BRAD BALDWIN - 03/2012026 @ 14:43 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 03120/2026 @ 14:43 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Heidi Fordyce (2026) CHECKLISTS Date: BRAD BALDWIN 03/20/2026 GENERATED ON 3/20/26, 2:46 PM 1 OF 5 Means of Egress Status Code Fail 1004.9 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Fire Alarm System Status Code Fail Chapter 14 - Inspection, testing, and maintenance Fire alarm system tested at least annually by licensed contractor General Housekeeping Status Code Fail 315.3.1- Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2-foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2,The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. Fire Sprinkler System Status Code Fail 5.2.1- Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor Description Location: Front exit Comments: Occupant Toad sign shall be permanently posted near main exit. Description Comments: Provide annual fire alarm inspection report including any deficiencies corrected to be uploaded to Compliance Engine. Inspection due 4t1t26. Description Location: 3rd floor storage areas behind curtains Comments: Lower all storage within 18inches below sprinkler heads Description Comments: Provide annual sprinkler system inspection report including any deficiencies corrected to be uploaded to Compliance Engine. Inspection due April 2026. GENERATED ON 3/20/26, 2:46 PH 2 OF 5 Electrical Safety Status Code Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum dear opening of 22 inches (559 mm) by 30 inches (762 min). Description Location: 3rd floor electric panel room Comments: Clearance of 36 inches in front of panel including down to floor and 30 inches in width to panel shall be maintained. Remove all storage within clearances. GENERATED ON 3/20/26, 2:46 PM 3 OF 5 Portable Fire Extingusihers Status Cain 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: All fire extinguishers Comments: Provide annual service to extinguishers, currently due in April 2026 Additional Codes Status Cods Description Fail 912.7 - Inspection, testing and maintenance. OFire department connections shall be periodically inspected, Location: Front of building tested and maintained in accordance with NFPA 25. Records Comments: Provide missing cap to Fire Department Connection. of inspection, testing and maintenance shall be maintained. GENERATED ON 3/20/26, 2:46 PM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 3/20/26, 2:46 PM 5 OF 5