HomeMy WebLinkAbout303 E ARLINGTON STINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
03/27/2026
05/01/2026
2026-00000086
$150.00
Customer #: 22500
GBM PROPERTY MGMT LLC
PO BOX 654
CEDAR FALLS, IA 50613
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 303 E ARLINGTON ST - 03/19/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 2ND
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
22500
03/27/2026
05/01/2026
2026-00000086
$150.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
k 150 22565
Waterloo Fire Rescue
Inspection Report
BLDG 303 East Arlington - 303 E Arlington ST, Waterloo IA 50703-2505
INSPECTION DETAILS
Inspection Date
03/19/2026
Lead Inspector
Randy Girsch
Inspection Type
2015 IPMC Rental Inspection REINSPECTION�_
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
21217-R1
Shift Station Unit
NIA
NIA N/A
SUMMARY OF INSPECTION
00 056
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
Randy Girsch
randy.girsch@waterloo-ia.org
GENERAL NOTES
Randy Girsch - 03/17/2026 @ 14:49
I would note that the bush near the front steps need to be trimmed away and properly pruned.
Reinspection Date
04/20/2026
Randy Girsch - 03/20/2026 @ 12:26
03-19-2026 RANDY GIRSCH Re -inspection date is as posted on the inspection report given, the rental unit's responsible personls shall reach out prior to
set time of that re -inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Please give the
appropriate notices to occupants of the unit/s. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given
or failure to keep the inspection will result in a $100 fee. *****Re inspection fees may be assessed for re1inspections. Re -inspection fees start at $50, then
$150, and $250 for all subsequent reCinspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection.
Randy Girsch - 03/20/2026 @ 12:35
03-19-2026 RANDY GIRSCH $100.00 failure to keep appointment fee. $50.00 re -inspection fee. I have attempted contact with the owner of this property and
left messages, emails, and put stickers on the dwelling with absolutely no response or compliance. The next inspection date for this residence will be
Monday April 20 2026 at 9am. I expect the owner of there residence or a representative to meet there on this day.
SIGNATURES
Contact signature Inspector signature
No signature
Contact refused - refused to contact me
Beth Shafer GBM Property Management Date:
CHECKLISTS
Randy Girsch 03/2012026
GENERATED ON 3/20/26, 12:50 PM 1 OF 10
Reinspection
Status
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Cock;
2015 IPMC 302.7 - Accessory structures
Accessory structures, including detached garages, fences
and walls, shall be maintained structurally sound and in good
repair.
2015 IPMC 304.13 - Window, skylight and door frames
Every window, skylight, door and frame shall be kept in
sound condition, good repair and weather tight.
2015 IPMC 304.13.1- Glazing
Glazing materials shall be maintained free from cracks and
holes.
2015 IPMC 304.13.1 - Glazing
Glazing materials shall be maintained free from cracks and
holes.
2015 IPMC 304.13.1- Glazing
Glazing materials shall be maintained free from cracks and
holes.
2015 IPMC 304.13.1 - Glazing
Glazing materials shall be maintained free from cracks and
holes.
2015 IPMC 304.15 - Doors
Exterior doors, door assemblies, operator systems if
provided, and hardware shall be maintained in good
condition. Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door. Locks on means
of egress doors shall be in accordance with Section 702.3.
2015 IPMC 304.15 - Doors
Exterior doors, door assemblies, operator systems if
provided, and hardware shall be maintained in good
condition. Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door. Locks on means
of egress doors shall be in accordance with Section 702.3.
2015 IPMC 304.18.2 - Windows
Operable windows located in whole or in part within 6 feet
(1828 mm) above ground level or a walking surface below that
provide access to a dwelling unit, rooming unit or
housekeeping unit that is rented, leased or let shall be
equipped with a window sash locking device.
2015 IPMC 304.18.2 - Windows
Operable windows located in whole or in part within 6 feet
(1828 mm) above ground level or a walking surface below that
provide access to a dwelling unit, rooming unit or
housekeeping unit that is rented, leased or let shall be
equipped with a window sash locking device.
Description
Location: Garage
Comments: Needs to be structurally sound and in good condition. A
permit through the city needs to be obtained to tare down otherwise
it needs attention.
Location: basement widows
Comments: Broken glass need to be in good repair or removed and
covered weather tight.
Location: South side of porch
Comments: window is broken and frame needs to be replaced
Location: Living room
Comments: Front window missing glass on the outside
Location: Kitchen
Comments: Window missing bottom portion of glass. Needs to be
corrected.
Location: Bedroom #1
Comments: Broken window needs to be fixed and weather tight
Location: Front door
Comments: Needs new door knob, parts are missing.
Location: Rear door in kitchen
Corments: Rear exit door going from kitchen is missing to handle.
Needs to have appropriate door handle and door needs to be weather
tight.
Location: Dining room
Comments: Window by air conditioner will not stay open. Needs to be
adjusted or replaced.
Location: Bathroom
Comments: Window will not shut properly and will not lock. Needs to
be replaced or repaired. All windows within 6 feet from ground level
must lock.
GENERATED ON 3/20/26, 12:50 PM 2 OF 10
Fail
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 304.18.2 - Windows
Operable windows located in whole or in part within 6 feet
(1828 mrn) above ground level or a walking surface below that
provide access to a dwelling unit, rooming unit or
housekeeping unit that is rented, leased or let shall be
equipped with a window sash locking device.
2015 IPMC 304.2 - Protective treatment
Exterior surfaces, including but not limited to, doors, door
and window frames, cornices, porches, trim, balconies, decks
and fences, shall be maintained in good condition. Exterior
wood surfaces, other than decay -resistant woods, shall be
protected from the elements and decay by painting or other
protective covering or treatment. Peeling, flaking and chipped
paint shall be eliminated and surfaces repainted. Siding and
masonry joints, as well as those between the building
envelope and the perimeter of windows, doors and skylights,
shall be maintained weather resistant and water tight. Metal
surfaces subject to rust or corrosion shall be coated to inhibit
such rust and corrosion, and surfaces with rust or corrosion
shall be stabilized and coated to inhibit future rust and
corrosion. Oxidation stains shall be removed from exterior
surfaces. Surfaces designed for stabilization by oxidation are
exempt from this requirement.
2015 IPMC 304.5 - Foundation walls
Foundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition
so as to prevent the entry of rodents and other pests.
2015 IPMC 304.7 - Roofs and drainage
The roof and flashing shall be sound, tight and not have
defects that admit rain. Roof drainage shall be adequate to
prevent dampness or deterioration in the walls or interior
portion of the structure. Roof drains, gutters and downspouts
shall be maintained in good repair and free from obstructions.
Roof water shall not be discharged in a manner that creates a
public nuisance.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 1PMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Location: Bedroom #1
Comments: Window on North side does not close or lock. Must be
corrected.
Location: exterior of dwelling
Comments: Siding on house need attention in places and should be
in good repair.
Location: Exterior of dwelling
Comments: Foundation is cracking and shows signs of shifting in
several places.
Location: Exterior of dwelling
Comments: Eve trough need cleaned and free of debris. Need to be
fastened to roof and all in working order. Water need to properly
drain to eve spouts and drain away from structure.
Location: Bathroom
Comments: Floor around toilet needs to be corrected. Possible
tripping hazard and needs to be free of bubbling
Location: Living room
Comments: Ceiling has water stains, cracks, and holes. Showing
signs of moisture. Investigate and correct
Location: Living room
Comments: Wall by front door has a hole in it. Needs to be repaired
GENERATED ON 3/20/26, 12:50 PM 3 OF 10
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 1PMC 305.3 - Interior surfaces
OInterior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Location: Dining room
Comments: Ceiling has stains and cracks in it. Showing sign of
moisture. Needs to be investigated and corrected.
Location: Dining room
Comments: Hole in wall by kitchen table. Needs to be repaired.
Location: Dining room
Comments: Flooring is missing where living room and dining room
meet. Needs to be repaired and have appropriate, even surface to
prevent trip hazard.
Location: Living room / Dining room /Kitchen
Comments: Walls need to be repaired all cracks, holes, peeling and
painted.
Location: Kitchen
Comments: Signs of moisture in ceiling. Needs to investigate and
correct and make sure the ceiling is properly secured.
Location: Kitchen
Comments: Cabinet door and drawers need to be corrected. All need
to be attached and in working order. Wood should be finished or
painted.
Location: Kitchen near refriderator
Comments: Flooring needs to be corrected to prevent tipping.
Location: Bathroom
Comments: Ceiling needs to be corrected. There is signs of moisture.
Investigate and correct.
Location: Bathroom bathtub
Comments: mold type substance on and around bathtub needs to be
cleaned and sealed.
GENERATED ON 3/20/26, 12:50 PM 4 OF 10
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
2015 IPMC 305.4 - Stairs and walking surfaces
Every stair, ramp, landing, balcony, porch, deck or other
walking surface shall be maintained in sound condition and
good repair.
2015 IPMC 305.5 - Handrails and guards
Every handrail and guard shall be firmly fastened and capable
of supporting normally imposed loads and shall be
maintained in good condition
Location: Bedroom #1
Comments: TVlentertainrnent center blocking egress for path out of
the window. Needs to be moved.
Location: Bathroom
Comments: Door needs to be fixed or replaced
Location: Hallway by bedroom #2
Comments: Flooring needs to be corrected and in good condition to
avoid tripping.
Location: Bedroom #2
Comments: Bunk bed needs to be moved to access egress to
window.
Location: Bedroom #2
Comments: closet needs to be corrected, hole in wall needs to be
repaired and painted
Location: Bedroom #2
Comments: Missing door knob/handle. Needs to be repaired or
replaced
Location: Kitchen
Comments: Signs of moisture under sink. Investigate and correct
Location: Rear ramp/deck needs to be i
Comments: Needs to be in good repair and properly installed. Need
to have a licensed contractor who needs proper permits and final
inspection.
Location: Front steps
Comments: handrail needs to be fasten securly
GENERATED ON 3/20/26, 12:50 PM 5 OF 10
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 403.2 - Bathrooms and toilet rooms
Every bathroom and toilet room shall comply with the
ventilation requirements for habitable spaces as required by
Section 403.1, except that a window shall not be required in
such spaces equipped with a mechanical ventilation system.
Air exhausted by a mechanical ventilation system from a
bathroom or toilet room shall discharge to the outdoors and
shall not be recirculated.
2015 IPMC 504.1 - General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 504.1- General - Plumbing Facilities and Fixture
Requirements
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition
2015 IPMC 505.1 - General - Water System
Every sink, lavatory, bathtub or shower, drinking fountain,
water closet or other plumbing fixture shall be properly
connected to either a public water system or to an approved
private water system. Kitchen sinks, lavatories, laundry
facilities, bathtubs and showers shall be supplied with hot or
tempered and cold running water in accordance with the
International Plumbing code
2015 IPMC 603.1- Mechanical appliances
Mechanical appliances, fireplaces, solid fuel -burning
appliances, cooking appliances and water heating appliances
shall be properly installed and maintained in a safe working
condition, and shall be capable of performing the intended
function.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Location: Bathroom
Comments: Exhaust fan not working. Needs to be in working order.
Location: Bathroom
Comments: Sink not draining properly. Need to unclog
Location: Bathroom
Comments: Cold side of faucet not running. Corrections need to be
made.
Location: basement
Comments: Standing sewage covering the entire basement. Needs to
be investigated and corrected.
Location: Kitchen
Comments: Stove needs repaired. Only one burner is working.
Location: Living room
Comments: Receptacle by TV shows "Open ground" Needs to have a
GFCI or two Prong
GENERATED ON 3/20/26, 12:50 PM 6 OF 10
Fail
Fail
Fail
Fail
Fail
Fail
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and rernote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroorn shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.2 - Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets. Every
laundry area shall contain not less than one grounding -type
receptacle or a receptacle with a ground fault circuit
interrupter. Every bathroom shall contain not less than one
receptacle. Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection. All receptacle
outlets shall have the appropriate faceplate cover for the
location.
2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen,
bathroom, laundry room, boiler room and furnace room shall
contain not less than one electric luminaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen,
bathroorn, laundry room, boiler room and furnace room shall
contain not less than one electric luminaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Location: Kitchen
Comments: Switch plate by back door needs to be corrected.
Location: Kitchen
Comments: Recepticle by stove has "open ground needs to have
GFCI put in.
Location: Kitchen
Comments: Receptacle by refrigerator needs to be tightened and
have proper outlet cover.
Location: Bedroom #1
Comments: Receptacle by closet had open ground. Needs to be
corrected.
Location: Back door
Comments: Light fixture has exposing wires and hanging down
Location: Font porch
Comments: Needs to have appropriate light fixture and globe
GENERATED ON 3/20/26, 12:50 PM
7 OF 10
Fail 2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen,
bathroom, laundry room, boiler room and furnace room shall
contain not less than one electric luminaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen,
bathroom, laundry room, boiler room and furnace room shall
contain not less than one electric luminaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3 - Luminaires
Every public hall, interior stairway, toilet room, kitchen,
bathroom, laundry room, boiler room and furnace room shall
contain not less than one electric luminaire. Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1
Single or multiple -station smoke alarms shall be installed and
maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Location: Living room
Comments: Light fixture needs to have appropriate globe
Location: Kitchen
Comments: Light on ceiling by stove does not work. Investigate and
correct.
Location: Bathroom
Comments: Light fixture needs globe.
Location: Bedroom #1
Comments: Missing smoke detector
Location: Bedroom #2
Comments: Missing smoke detector
Location: Hallway outside bedrooms
Comments: Missing smoke detector
GENERATED ON 3/20/26, 12:50 PM
8 OF 10
Fail
Fail
Fail
2021 IRC R315.3 - Carbon Monoxide Detection: Location
Carbon monoxide alarms in dwelling units shall be installed
outside of each separate sleeping area in the immediate
vicinity of the bedrooms. Where a fuel -burning appliance is
located within bedroom or its attached bathroom, a carbon
monoxide alarm shall be installed within the bedroom.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
R4 - Exterior Property Areas
Is the exterior property area maintained in a clean, safe, and
sanitary condition? This includes grading and drainage,
sidewalks and driveways, weeds, and pest infestations. (IPMC
302)
Location: Hallway outside bedrooms
Comments: Missing carbon monoxide detector
Location: Bedroom #2
Comments: The AC plug in adapter that plugs into the electrical
outlet is broken off and needs to be corrected. Needs to have cover
to prevent any hazard of shock.
Location: Exterior of dwelling
Comments: Soffit needs to be in good repair and painted
GENERATED ON 3/20/26, 12:50 PM
9 OF 10
o
FEE
Statement of Fees
Invoice Date Inspection Fee Date Paid Amount Paid
N/A $150.00
Invoice Number
NIA
Check Number Transaction Number
NIA N/A