Loading...
HomeMy WebLinkAbout303 E ARLINGTON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/27/2026 05/01/2026 2026-00000086 $150.00 Customer #: 22500 GBM PROPERTY MGMT LLC PO BOX 654 CEDAR FALLS, IA 50613 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 303 E ARLINGTON ST - 03/19/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22500 03/27/2026 05/01/2026 2026-00000086 $150.00 Less Prepayment Total Due — City of Waterloo $0.00 $150.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. k 150 22565 Waterloo Fire Rescue Inspection Report BLDG 303 East Arlington - 303 E Arlington ST, Waterloo IA 50703-2505 INSPECTION DETAILS Inspection Date 03/19/2026 Lead Inspector Randy Girsch Inspection Type 2015 IPMC Rental Inspection REINSPECTION�_ Other Inspectors NIA 425 E. 3rd Street Inspection Number 21217-R1 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 00 056 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Randy Girsch randy.girsch@waterloo-ia.org GENERAL NOTES Randy Girsch - 03/17/2026 @ 14:49 I would note that the bush near the front steps need to be trimmed away and properly pruned. Reinspection Date 04/20/2026 Randy Girsch - 03/20/2026 @ 12:26 03-19-2026 RANDY GIRSCH Re -inspection date is as posted on the inspection report given, the rental unit's responsible personls shall reach out prior to set time of that re -inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Please give the appropriate notices to occupants of the unit/s. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the inspection will result in a $100 fee. *****Re inspection fees may be assessed for re1inspections. Re -inspection fees start at $50, then $150, and $250 for all subsequent reCinspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection. Randy Girsch - 03/20/2026 @ 12:35 03-19-2026 RANDY GIRSCH $100.00 failure to keep appointment fee. $50.00 re -inspection fee. I have attempted contact with the owner of this property and left messages, emails, and put stickers on the dwelling with absolutely no response or compliance. The next inspection date for this residence will be Monday April 20 2026 at 9am. I expect the owner of there residence or a representative to meet there on this day. SIGNATURES Contact signature Inspector signature No signature Contact refused - refused to contact me Beth Shafer GBM Property Management Date: CHECKLISTS Randy Girsch 03/2012026 GENERATED ON 3/20/26, 12:50 PM 1 OF 10 Reinspection Status Fail Fail Fail Fail Fail Fail Fail Fail Fail Fail Cock; 2015 IPMC 302.7 - Accessory structures Accessory structures, including detached garages, fences and walls, shall be maintained structurally sound and in good repair. 2015 IPMC 304.13 - Window, skylight and door frames Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight. 2015 IPMC 304.13.1- Glazing Glazing materials shall be maintained free from cracks and holes. 2015 IPMC 304.13.1 - Glazing Glazing materials shall be maintained free from cracks and holes. 2015 IPMC 304.13.1- Glazing Glazing materials shall be maintained free from cracks and holes. 2015 IPMC 304.13.1 - Glazing Glazing materials shall be maintained free from cracks and holes. 2015 IPMC 304.15 - Doors Exterior doors, door assemblies, operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. 2015 IPMC 304.15 - Doors Exterior doors, door assemblies, operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. 2015 IPMC 304.18.2 - Windows Operable windows located in whole or in part within 6 feet (1828 mm) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. 2015 IPMC 304.18.2 - Windows Operable windows located in whole or in part within 6 feet (1828 mm) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. Description Location: Garage Comments: Needs to be structurally sound and in good condition. A permit through the city needs to be obtained to tare down otherwise it needs attention. Location: basement widows Comments: Broken glass need to be in good repair or removed and covered weather tight. Location: South side of porch Comments: window is broken and frame needs to be replaced Location: Living room Comments: Front window missing glass on the outside Location: Kitchen Comments: Window missing bottom portion of glass. Needs to be corrected. Location: Bedroom #1 Comments: Broken window needs to be fixed and weather tight Location: Front door Comments: Needs new door knob, parts are missing. Location: Rear door in kitchen Corments: Rear exit door going from kitchen is missing to handle. Needs to have appropriate door handle and door needs to be weather tight. Location: Dining room Comments: Window by air conditioner will not stay open. Needs to be adjusted or replaced. Location: Bathroom Comments: Window will not shut properly and will not lock. Needs to be replaced or repaired. All windows within 6 feet from ground level must lock. GENERATED ON 3/20/26, 12:50 PM 2 OF 10 Fail Fail Fail Fail Fail Fail Fail 2015 IPMC 304.18.2 - Windows Operable windows located in whole or in part within 6 feet (1828 mrn) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. 2015 IPMC 304.2 - Protective treatment Exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences, shall be maintained in good condition. Exterior wood surfaces, other than decay -resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. Siding and masonry joints, as well as those between the building envelope and the perimeter of windows, doors and skylights, shall be maintained weather resistant and water tight. Metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. 2015 IPMC 304.5 - Foundation walls Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. 2015 IPMC 304.7 - Roofs and drainage The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 1PMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Location: Bedroom #1 Comments: Window on North side does not close or lock. Must be corrected. Location: exterior of dwelling Comments: Siding on house need attention in places and should be in good repair. Location: Exterior of dwelling Comments: Foundation is cracking and shows signs of shifting in several places. Location: Exterior of dwelling Comments: Eve trough need cleaned and free of debris. Need to be fastened to roof and all in working order. Water need to properly drain to eve spouts and drain away from structure. Location: Bathroom Comments: Floor around toilet needs to be corrected. Possible tripping hazard and needs to be free of bubbling Location: Living room Comments: Ceiling has water stains, cracks, and holes. Showing signs of moisture. Investigate and correct Location: Living room Comments: Wall by front door has a hole in it. Needs to be repaired GENERATED ON 3/20/26, 12:50 PM 3 OF 10 Fail Fail Fail Fail Fail Fail 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Fail 2015 1PMC 305.3 - Interior surfaces OInterior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Location: Dining room Comments: Ceiling has stains and cracks in it. Showing sign of moisture. Needs to be investigated and corrected. Location: Dining room Comments: Hole in wall by kitchen table. Needs to be repaired. Location: Dining room Comments: Flooring is missing where living room and dining room meet. Needs to be repaired and have appropriate, even surface to prevent trip hazard. Location: Living room / Dining room /Kitchen Comments: Walls need to be repaired all cracks, holes, peeling and painted. Location: Kitchen Comments: Signs of moisture in ceiling. Needs to investigate and correct and make sure the ceiling is properly secured. Location: Kitchen Comments: Cabinet door and drawers need to be corrected. All need to be attached and in working order. Wood should be finished or painted. Location: Kitchen near refriderator Comments: Flooring needs to be corrected to prevent tipping. Location: Bathroom Comments: Ceiling needs to be corrected. There is signs of moisture. Investigate and correct. Location: Bathroom bathtub Comments: mold type substance on and around bathtub needs to be cleaned and sealed. GENERATED ON 3/20/26, 12:50 PM 4 OF 10 Fail Fail Fail Fail Fail Fail Fail Fail Fail 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. 2015 IPMC 305.4 - Stairs and walking surfaces Every stair, ramp, landing, balcony, porch, deck or other walking surface shall be maintained in sound condition and good repair. 2015 IPMC 305.5 - Handrails and guards Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition Location: Bedroom #1 Comments: TVlentertainrnent center blocking egress for path out of the window. Needs to be moved. Location: Bathroom Comments: Door needs to be fixed or replaced Location: Hallway by bedroom #2 Comments: Flooring needs to be corrected and in good condition to avoid tripping. Location: Bedroom #2 Comments: Bunk bed needs to be moved to access egress to window. Location: Bedroom #2 Comments: closet needs to be corrected, hole in wall needs to be repaired and painted Location: Bedroom #2 Comments: Missing door knob/handle. Needs to be repaired or replaced Location: Kitchen Comments: Signs of moisture under sink. Investigate and correct Location: Rear ramp/deck needs to be i Comments: Needs to be in good repair and properly installed. Need to have a licensed contractor who needs proper permits and final inspection. Location: Front steps Comments: handrail needs to be fasten securly GENERATED ON 3/20/26, 12:50 PM 5 OF 10 Fail Fail Fail Fail Fail Fail 2015 IPMC 403.2 - Bathrooms and toilet rooms Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. 2015 IPMC 504.1 - General - Plumbing Facilities and Fixture Requirements Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition 2015 IPMC 504.1- General - Plumbing Facilities and Fixture Requirements Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition 2015 IPMC 505.1 - General - Water System Every sink, lavatory, bathtub or shower, drinking fountain, water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. Kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the International Plumbing code 2015 IPMC 603.1- Mechanical appliances Mechanical appliances, fireplaces, solid fuel -burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function. 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. Location: Bathroom Comments: Exhaust fan not working. Needs to be in working order. Location: Bathroom Comments: Sink not draining properly. Need to unclog Location: Bathroom Comments: Cold side of faucet not running. Corrections need to be made. Location: basement Comments: Standing sewage covering the entire basement. Needs to be investigated and corrected. Location: Kitchen Comments: Stove needs repaired. Only one burner is working. Location: Living room Comments: Receptacle by TV shows "Open ground" Needs to have a GFCI or two Prong GENERATED ON 3/20/26, 12:50 PM 6 OF 10 Fail Fail Fail Fail Fail Fail 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and rernote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroorn shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, bathroorn, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Location: Kitchen Comments: Switch plate by back door needs to be corrected. Location: Kitchen Comments: Recepticle by stove has "open ground needs to have GFCI put in. Location: Kitchen Comments: Receptacle by refrigerator needs to be tightened and have proper outlet cover. Location: Bedroom #1 Comments: Receptacle by closet had open ground. Needs to be corrected. Location: Back door Comments: Light fixture has exposing wires and hanging down Location: Font porch Comments: Needs to have appropriate light fixture and globe GENERATED ON 3/20/26, 12:50 PM 7 OF 10 Fail 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 2015 IPMC 605.3 - Luminaires Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain not less than one electric luminaire. Pool and spa luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1 Single or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1 Single or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2 - Groups R-2, R-3, R-4 and 1-1 Single or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Location: Living room Comments: Light fixture needs to have appropriate globe Location: Kitchen Comments: Light on ceiling by stove does not work. Investigate and correct. Location: Bathroom Comments: Light fixture needs globe. Location: Bedroom #1 Comments: Missing smoke detector Location: Bedroom #2 Comments: Missing smoke detector Location: Hallway outside bedrooms Comments: Missing smoke detector GENERATED ON 3/20/26, 12:50 PM 8 OF 10 Fail Fail Fail 2021 IRC R315.3 - Carbon Monoxide Detection: Location Carbon monoxide alarms in dwelling units shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms. Where a fuel -burning appliance is located within bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Location: Hallway outside bedrooms Comments: Missing carbon monoxide detector Location: Bedroom #2 Comments: The AC plug in adapter that plugs into the electrical outlet is broken off and needs to be corrected. Needs to have cover to prevent any hazard of shock. Location: Exterior of dwelling Comments: Soffit needs to be in good repair and painted GENERATED ON 3/20/26, 12:50 PM 9 OF 10 o FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid N/A $150.00 Invoice Number NIA Check Number Transaction Number NIA N/A GENERATED ON 3/20/26, 12:50 PM 10 OF 10