HomeMy WebLinkAbout117 E SAN MARNAN DRINVOICE DATE
DUE DATE
INVOICE#
TOTAL DUE
04/07/2026
05/12/2026
2026-00000414
$100.00
Customer #: 24676
THE SPOT #3
117 E SAN MARNAN DR
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 117 E SAN MARNAN DR -
04/03/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 1
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24676
04/07/2026
05/12/2026
2026-00000414
$100.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
1.HL l (i I 150
Waterloo Fire Rescue
Inspection Report
The Spot #3 - 117Ugn Marnan DR, BL.DG 117 E San Marnan Dr, Waterloo IA 50702
INSPECTION DETAILS
Inspection Date
04/03/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
NIA
Shift
N/A
Station
NIA
425 E. 3rd Street
Inspection Number
17913-R2
Unit
NIA
SUMMARY OF INSPECTION
0 3 0 4 0 17
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 04/03/2026 @ 13:42
$100 re -inspection fee, failure to complete corrections on 413126
BRAD BALDWIN - 03/13/2026 @ 13:04
$80 annual inspection fee
BRAD BALDWIN - 03/13/2026 @ 13:04
Ceiling tiles noted missing today during active remodel, all ceiling tiles shall be re -installed after project is complete.
BRAD BALDWIN - 03/13/2026 @ 13:04
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
04/24/2026
BRAD BALDWIN - 03/1312026 @ 13:04
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 03/13/2026 @ 13:04
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 am. - 4:00 p.m. "****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 03/13/2026 @ 13:04
Staff member removed propane tank from building as directed by inspector today 2/18/26.
BRAD BALDWIN - 03/13/2026 @ 13:04
Withholding re -inspections due to construction project in progress, complete corrections to avoid fees
SIGNATURES
Contact signature Inspector signature
GENERATED ON 4/3/26, 1:44 PM 1 OF 10
No signature
Report completed post inspection
Malik (2025) Date:
CHECKLISTS
BRAD BALDWIN 04/03/2026
GENERATED ON 4/3/26, 1:44 PM
2 OF 10
L
Reinspection
Status
Fail
Fail
Fail
Fail
Code
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
2303.2 - Emergency disconnect switches.
An approved emergency disconnect switch shall be provided
at an approved location to stop the transfer of fuel to the fuel
dispensers in the event of a fuel spill or other emergency. The
emergency disconnect switch for exterior fuel dispensers
shall be provided with ready access and shall be located
within 100 feet (30 480 mm) of, but not Tess than 20 feet (6096
mm) from, the fuel dispensers. For interior fuel -dispensing
operations, the emergency disconnect switch shall be
provided with ready access and be installed at an approved
location. Such devices shall be distinctly labeled as:
"EMERGENCY FUEL SHUTOFF." Signs shall be
provided in approved locations.
Description
Location: Remodel project
Comments: All necessary permits shall be obtained including
inspections completed for active remodel project.
Location: Above ceiling water heater for bathroom
Comments: Licensed plumbing contractor shall obtain permit and
inspection of water heater
Location: Emergency egress light above front exit
Comments: Repair or replace egress lighting that failed to illuminate
during test.
Additional comments: Failed test today 413126
Location: Emergency fuel shut-off switch
Comments: Unable to find emergency switch. Locate switch and
provide easy access to or install emergency switch to referenced
code standards.
Additional comments: Switch obstructed by chew tobacco shelf
today 4/3/26, remove obstruction to maintain clear access.
GENERATED ON 4/3/26, 1:44 PM 3 OF 10
Fail
Fail
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures AU electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
Location: Honeycomb lighting and "C4 Energy" Fridge
Comments: Provide documentation lighting and fridge is approved to
plug to power strip or remove from power strip and plug to
permanent outlet. Power strips shall be properly mounted to avoid
hanging by wires.
Location: Honeycomb ceiling lighting
Comments: Provide documentation of proper listing of LED lighting
and usage is compliant with the listing.
GENERATED ON 4/3/26, 1:44 PM
4 OF 10
Fail
Fail
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Location: Window LED lighting
Comments: Provide documentation of proper listing of LED lighting
and usage is compliant with the listing.
Additional comments: No documentation received as of 4/3126
Location: Liquor storage room
Comments: Blue extension cord noted under shelving altered to
exposing bare wires shall be removed from building or licensed
electrician shall make necessary repair. Obtain copy of receipt of
repair by electrician.
Additional comments: Cord still present on site on 4/3/26. Remove
cord from building immediately.
GENERATED ON 4/3/26, 1:44 PM
5 OF 10
Fail
Fail
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Location: North exterior
Comments: Provide proper cover to conduit elbow exposing wires
Location: Electric panel near back door
Comments: Provide blank cover to opening in panel.
Additional comments: All openings in electric panLi shall be properly
covered to avoid shock hazard
GENERATED ON 4/3/26, 1:44 PM
6 OF 10
Fail
0
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Location: Behind counter below cigarette shelf
Comments: Provide missing outlet cover
GENERATED ON 4/3/26, 1:44 PM
7 OF 10
Fail
Fail
603.4 - Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
Tess, and Section 110.33 of NFPA 70 for electrical equiprent
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 rnm).
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Back storage
Comments: Remove obstructions to clear path of access to electric
panel. Maintain 36" clearance in front of panel at all times.
Location: Slushie machines
Comments: Remove appliances plugged to extension cord.
Appliances shall plug directly to permanent outlet.
GENERATED ON 4/3/26, 1:44 PM
8 OF 10
Fail
Fail
®
906.7 - Hangers and brackets.
Hand-held portable fire extinguishers, not housed in cabinets,
shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the
mounting surface in accordance with the manufacturer's
installation instructions.
906.7 - Hangers and brackets.
Hand-held portable fire extinguishers, not housed in cabinets,
shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the
mounting surface in accordance with the manufacturer's
installation instructions.
Additional Codes
Status Code
Fail
Fail
®
5003.2.6 - Maintenance.
In addition to the requirements of Section 5003.2.3,
equipment, machinery and required detection and alarm
systems associated with hazardous materials shall be
maintained in an operable condition. Defective containers,
cylinders and tanks shall be removed from service, repaired
or disposed of in an approved manner. Defective equipment
or machinery shall be removed from service and repaired or
replaced. Required detection and alarm systems shall be
replaced or repaired where defective.
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Aisles
Comments: Extinguisher shall be annually serviced and mounted on
wall brackets in required location. Currently sitting on floor.
Location: Back storage near back door
Comments: Multiple extinguishers sitting on floor. Extinguishers
shall be annually serviced and mounted on wall brackets in required
locations. Spare extinguishers shall be removed from building.
Description
Location: Pumps 5 & 6
Comments: Pumps noted out of service today 413126, necessary
repairs shall be completed to maintain proper working order
Location: Behind ATM machine
Comments: Remove multi -plug cords and adapters. Power strips
usage shall comply with electrical codes.