Loading...
HomeMy WebLinkAbout102 TOWER PARK RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/07/2026 05/12/2026 2026-00000408 $80.00 Customer #: 12217 VERIDIAN CREDIT UNION - TOWER PARK 57 E TOWER PARK DR WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 102 TOWER PARK DR - 04/07/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE NVOICE # CHARGES 12217 04/07/2026 05/12/2026 2026-00000408 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. A a • ; Waterloo Fire Rescue $go nspection Report Veridian Credit Union - Park DG 102 Tower Park Dr, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 04/07/2026 Lead Inspector BRAD BALDWIN Inspection Type intionammenms (WYr)' Other lnspectors NIA Shift N/A Station NIA 425 E. 3rd Street Inspection Number 21621 Unit N/A SUMMARY OF INSPECTION 0 35 Passed codes NEXT STEPS 03 ®36 Failed codes N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/07/2026 @ 12:40 $80 annual inspection fee Reinspection Date 05/07/2026 BRAD BALDWIN - 04/07/2026 @ 13:32 Corrected prior to 4/7126 inspection: Slide bolt locks at all main exit doors removed on 4/6/26. (2021 IFC) 1010.2.5 Bolt locks: Manually operated flush bolts or surface bolts are not permitted. SIGNATURES Contact signature No signature Report completed post inspection Dave Schares - Facilities Manager CHECKLISTS Additional Codes Status Code Fail 0 Date: 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Inspector signature 3R BRAD BALDWIN Description Location: HVAC permit 04107/2026 Comments: Contractor (Waldinger Corp.) shall obtain inspection of work when completed. GENERATED ON 4/7/26, 1:47 PM 1 OF 3 General Housekeeping Status Code Fail o 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Portable Fire Extingusihers Status Code Fail 0 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Mechanical rooms (2) Comments: Remove all combustible materials within 36" of furnaces. Maintain proper clearances at all times. Description Location: Fire extinguishers Comments: Provide annual service to all extinguishers, currently due April 2026 GENERATED ON 4/7/26, 1:47 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 4/7/26, 1:47 PM 3 OF 3