Loading...
HomeMy WebLinkAbout850 PARK RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/07/2026 05/12/2026 2026-00000422 $100.00 Customer #: 11090 RIVER FRONT STADIUM 850 PARK RD WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 850 PARK RD - 03/31 /2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # 11090 BILLING DATE 04/07/2026 DUE DATE 05/12/2026 INVOICE # 2026-00000422 Less Prepayment Total Due — City of Waterloo CIIARGES $100.00 $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 4too 11096 Waterloo Fire Rescue Inspection Report Waterloo Riverfront Stadium - 8 k RD, BLDG 850 Park Rd, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 03/3112026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA SUMMARY OF INSPECTION 0 48 09 ®20 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 03/31/2026 @ 12:29 $100 annual inspection fee BRAD BALDWIN - 03/31/2026 @ 13:42 Shift N/A 425 E. 3rd Street Inspection Number 16827 Station Unit NIA NIA • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 04/21/2026 BRAD BALDWIN - 0313112026 @ 13:42 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 03131/2026 @ 13:43 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then S150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Dan Corbin GM CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 03/31/2026 GENERATED ON 3/31/26, 1:45 PM 1 OF 7 v- Electrical Safety Status Cede Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: 3rd base party deck ramp Comments: Licensed electrician shall repair outlet broken from conduit. Location: 3rd base party deck Comments: Replace missing outlet cover, SW corner of deck GENERATED ON 3/31/26, 1:45 PM 2 OF 7 Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Near grill storage and 3rd base side conoession Comments: Replace missing outlet cover GENERATED ON 3/31/26, 1:45 PM 3 OF 7 Additional Codes Status Code Fail Fail 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer&ft039;s operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. 907.4.2.6 - Unobstructed and unobscured. Manual fire alarm boxes shall be provided with ready access, unobstructed, unobscured and visible at all times. Description Location: Clothes dryer vents Comments: Provide documentation of cleaning of dryer vent from appliance to the exterior of the building with signature and date. Email documentation to fire inspector, Location: Hallway from Bucks locker room to front gate exit Comments: Remove cabinet obstructing visual of and easy access to alarm pull station. GENERATED ON 3/31/26, 1:45 PM 4 OF 7 — \ a Fire Resistant Construction Maintenance State code Fail Fail Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Description Location: Hallway from Bucks locker room to front gate exit Comments: Replace missing ceiling tiles. Location: Hallway between Bucks locker room and 3rd base concession Comments: Replace all missing ceiling tiles. Location: Bucks locker room - Mechanical room Comments: Repair or replace door to mechanical room that failed to self -shut and latch. Replacing door requires permit and inspection obtained. GENERATED ON 3/31/26, 1:45 PM 5 OF 7 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: All extinguishers Comments: Provide annual service to extinguishers, currently due now. GENERATED ON 3/31/26, 1:45 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee N/A $100.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 3/31/26, 1:45 PM 7 OF 7