Loading...
HomeMy WebLinkAbout2026 BOPP ST0 0 • • O INVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/14/2026 05/19/2026 2026-00000427 $80.00 Customer #: 24679 POPPY'S SPORTS PUB 2026 BOPP WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2026 BOPP ST - 04/09/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24679 04/14/2026 05/19/2026 2026-00000427 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. tt) 24G119 Waterloo Fire Rescue Inspection Report Poppy's Sports Pub BLDG 2026 Bopp St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 04/09/2026 Lead inspector BRAD BALDWIN Inspection Type Other Inspectors N/A 425 E.3rd Street Inspection Number 16419 Shift Station Unit N/A N/A N/A SUMMARY OF INSPECTION 0 40 Passed codes NEXT STEPS U 13 Failed codes 25 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/1312026 @ 14:41 $80 annual inspection fee BRAD BALDWIN - 04113/2026 @ 15:52 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 0411312026 @ 15:52 Reinspection Date 05/06/2026 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 04/1312026 @ 15:52 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Shannon Jones 2026 Date: BRAD BALDWIN 04,113/2026 CHECKLISTS GENERATED ON 4/13/26, 3:54 PM 1 OF 7 Additional Codes statdd rode Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seisrnic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Description Location: Water heater Comments: Licensed plumbing contractor shall obtain permit and inspection of water heater installed (manufactured 2025) without permit. Location: Kitchen storage room electric panel Comments: Remove obstructions to clear access to electric panel, maintain 36 " clearance around panel at all times. Location: Liquor room near bar Comments: Provide chain to tanks to avoid tip -over hazard GENERATED ON 4/13/26, 3:54 PM 2 OF 7 Fail 606.3.1- Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Emergency Equipment steru<: Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2,6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Kitchen hood exhaust Comments: Close gaps in filters. Filters not in place eause more grease in ductwork and on cables for fire suppression. Also, install loose suppression nozzle caps back on to avoid grease accumulation, see attached photos Description Location: Kitchen - near hood exhaust Comments: Repair or replace egress lighting, very dial when tested. Location: East dining area - South door Comments: Repair or replace exit sign that failed to illuminate during test. GENERATED ON 4/13/26, 3:54 PM 3 OF 7 Electrical Safety Status Cade Description Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Walk-in fridge Comments: Provide moisture proof cover on Tight fixture Location: Kitchen office Comments: Properly mount power strip to wall to avoid hanging by wires Location: East dining area, behind casino games Comments: Properly mount power strip to avoid hanging by wires GENERATED ON 4/13/26, 3:54 PM 4 OF 7 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Fail 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: East dining area, near darts Comments: Remove TV's plugged to extension cords, TV may plug to properly mounted power strip with manual reset plugged to wall outlet. Remove flexible cords behind TV's extending through drop ceiling. Description Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 211 days past due as of 4/13/26 GENERATED ON 4/13/26, 3:54 PM 5 OF 7 Fire Resistant Construction Maintenance Cone Description Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Portable Fire Extingusihers Status Location: Kitchen storage room and office Comments: Provide missing ceiling tiles. Code Description Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: All extinguishers Comments: Provide annual service to extinguishers, last recorded service completed March 2025 GENERATED ON 4/13/26, 3:54 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N►A $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 4/13/26, 3;54 PM 7 OF 7