Loading...
HomeMy WebLinkAbout2313 LOGAN AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/21/2026 05/26/2026 2026-00000433 $100.00 Customer #: 24067 GREENLEAF TOBACCO AND E-CIGS 1503 E SAN MARNAN DR SUITE C WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2313 LOGAN AVE - 04/17/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24067 04/21/2026 05/26/2026 2026-00000433 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ZL10 INIaftw Waterloo Fire Rescue Inspection Report Greenleaf Vape & TobaccoaIIIIIMVE, BLDG 2313 Logan Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shift NIA 425 E. 3rd Street Inspection Number 21242-R1 Station Unit NIA NIA SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS 2 ® 12 Resolved violations Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04117/2026 @ 13:28 $100 re -inspection due to lack of progress on 4/17126, complete corrections to avoid more fees at following inspections BRAD BALDWIN - 03/1912026 @ 09:07 • $80 annual inspection fee BRAD BALDWIN - 03/1912026 @ 09:07 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN - 03/19/2026 @ 09:07 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 03/1912026 @ 09:07 Reinspection Date 05115/2026 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 03/1912026 @ 09:07 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection MO (2026) Date: BRAD BALDWIN 0411712026 GENERATED ON 4/17/26, 1:30 PM 1 OF 9 CHECKLISTS GENERATED ON 4/17/26, 1:30 PM 2 OF 9 Reinspection . Fail Fail Fail Fail Fail Code Description 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not Tess than 90 minutes. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: Cigar room Comments: Building and electrical permits and inspections shall be obtained for cigar room built without permits. Additional comments: No permits on file 4/17/26 Location: Water heater Comments: Licensed plumbing contractor shall obtain permit and inspection of water heater installed without permit. Additional comments: No permits on file 4117/26 Location: Front exit Comments: Repair or replace exit sign and lights than failed to illuminate during test. Additional comments: No progress today 4/17/26 Location: Window LED lighting Comments: Provide documentation of proper listing and use of listing of lighting. Additional comments: No progress today 4117126 Location: Display cases near front wall Comments: Provide further information to inspector of nature of white cords extending from under display cases. If extension cords, remove. Additional comments: No progress today 4/17/26 GENERATED ON 4/17/26, 1:30 PM 3 OF 9 Fail 0 Fail 0 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front window above fridge Comments: Properly mount power strip to avoid hanging by wires, Additional comments: No progress today 4/17126 Location: Front wall Comments: Remove extension cord plugged to power strip. Power strip shall be properly mounted to wall to avoid hanging by wires and plugged directly to outlet. Additional comments: No progress today 4/17126 GENERATED ON 4/17/26, 1:30 PM 4 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front window Comments: Remove extension cord plugged to power strip Additional comments: No progress today 4/17/26 GENERATED ON 4/17/26, 1:30 PM 5 55 5 Fail 603.6 - Extension cords. Extension cords and flexible cordsshali not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front wall behind display cases Comments: Remove white extension cord taped to floor. Cords running across walkway shall be protected by listed floor cord protector. Additional comments: No progress today 4117126 GENERATED ON 4/17/26, 1:30 PM 6 OF 9 Fail 603.6 • Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind counter below register counter Comments: Provide further information regarding use of white cord extending from below cabinet plugged to power strip. Additional comments: No progress today 4117126 GENERATED ON 4/17/26, 1:30 PM 7 OF 9 Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 906.5 - Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will have ready access and be immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Location: Behind register, cigarette shelving Comments: Remove white cord extending through above ceiling. Additional comments: No progress today 4/17126 Location: Below register counter Comments: Fire extinguisher shall be relocated to a conspicuous location. Currently covered by bags and hidden. Additional comments: No progress today 4117126 GENERATED ON 4/17/26, 1:30 PM 8 OF 9 re Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Date Paid Amount Paid Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 4/17/26, 1:30 PM 9 OF 9