Loading...
HomeMy WebLinkAbout1309 LAFAYETTE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/21/2026 05/26/2026 2026-00000441 $80.00 Customer #: 23198 PRIME MART 7 1309 LAFAYETTE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1309 LAFAYETTE ST - 04/14/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23198 04/21/2026 05/26/2026 2026-00000441 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. C Waterloo Fire Rescue Inspection Report Prime Mart 7 - 1309 Lafayette ST, BLDG 1309 Lafayette St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 1111111110 Lead Inspector BRAD BALDWIN Inspection Type Other inspectors N/A 425 E. 3rd Street Inspection Nurser 16759 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 32 Passed codes NEXT STEPS 0 11 ®36 Failed codes NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 0411512026 @ 08:26 $80 Annual inspection fee BRAD BALDWIN - 04/1612026 @ 07:22 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 05/0712026 BRAD BALDWIN - 04/16/2026 @ 07:23 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 04/1612026 @ 07:23 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Usman Chatha 2026 Date: BRAD BALDWIN 0411612026 CHECKLISTS GENERATED ON 4/16/26, 7:25 AM 1 OF 9 Additional Codes Status Code Fail Fail Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.9.1- Listed and labeled. Only listed and labeled portable, electric space heaters shall be used. Description Location: Electric permit Comments: Contractor (B & C Electric of Iowa) shall obtain inspection of work completed. Permit obtained for "12 outlets" in December 2025. Location: LED lighting (front exterior windows & above coolers) Comments: Provide documentation of listing of lights. Lighting shall be properly listed and comply with listing. Location: Liquor storage Comments: Provide documentation of proper listing and labeling of commercially approved heater or remove from building. GENERATED ON 4/16/26, 7:25 AM 2 OF 9 Electrical Safety States Code Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Near Lotto machine/register counter Comments: Conduit drop shall be properly supported, currently not anchored or supported to anything. Also, outlet cover is loose and shall be properly installed to avoid exposing wires in box. Location: Front of building near ice machine Comments: Exterior rated cover shall be installed and repairs made to avoid exposed wiring to exterior elements. GENERATED ON 4/16/26, 7:25 AM 3 OF 9 Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Near front exit - behind Coke fridge Comments: Replace broken outlet cover GENERATED ON 4/16/26, 7:25 AM 4 OF 9 Fail Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Tess, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Back storage room Comments: Remove storage within 36 inches of electric panels. Maintain proper clearances and ready access to panels at all times. Location: Register counter Comments: Remove power strip plugged to another power strip near register, must plug directly to wall outlet. GENERATED ON 4/16/26, 7:25 AM 5 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind counter Comments: Remove green extension cord GENERATED ON 4/16/26, 7:25 AM 6 OF 9 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Above Monster bev fridge at front wall of building. Comments: Remove black cord extending above drop ceiling. GENERATED ON 4/16/26, 7:25 AM 7 OF 9 Portable Fire Extingusihers Status Code Fail 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Liquor storage Comments: Install fire extinguisher on wall bracket in required location, currently sitting on floor. GENERATED ON 4/16/26, 7:25 AM 8 OF 9 Eo FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 4/16/26, 7:25 AM 9 OF 9