COMMERCIAL INSPECTION - 2424 RANCHERO RD - 04/20/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
15371
04/21/2026
05/26/2026
2026-00000436
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
I
Waterloo Fire Rescue
Inspection Report
Casey's General Store #2867 aillillainimpet.DG 2867 Ranchero Rd,
Waterloo IA 50701
INSPECTION DETAILS
Inspec
Lead Inspector
BRAD BALDWIN
Inspection Type
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
16971
Shift Station Unit
NIA
NIA NIA
SUMMARY OF INSPECTION
0 44 0 9 ®25
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 04/2012026 @ 15:20
$80 annual inspection fee
BRAD BALDWIN - 04/20/2026 @ 15:38
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 04/20/2026 @ 15:39
Reinspection Date
05/12/2026
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 04/20/2026 @ 15:39
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
Karri Dorsey 2026
CHECKLISTS
No signature
Report completed post inspection
Date: BRAD BALDWIN 04/20/2026
GENERATED ON 4/20/26, 3:41 PM 1 OF 8
Additional Codes
Status Code Description
GENERATED ON 4/20/26, 3:41 PM
2 OF 8
Fail
1010.2.4 - Locks and latches.
Locks and latches shall be permitted to prevent operation of
doors where any of the following exist: 1.Places of detention
or restraint. 2.In Group 1-1, Condition 2 and Group 1-2
occupancies where the clinical needs of persons receiving
care require containment or where persons receiving care
pose a security threat, provided that all clinical staff can
readily unlock doors at all times, and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times. 2. 3. In buildings in occupancy Group A
having an occupant load of 300 or less, Groups B, F, M and S,
and in places of religious worship, the main door or doors are
permitted to be equipped with key -operated locking devices
from the egress side provided: 2.1. 3.1. The locking device is
readily distinguishable as locked. 2.2. 3.2. A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch
(25 min) high on a contrasting background. 2.3. 3.3. The use
of the key -operated locking device is revocable by the fire
code official for due cause. 3.4. Where egress doors are used
in pairs, approved automatic flush bolts shall be permitted to
be used, provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface -mounted
hardware. 4. 5. Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch, dead
bolt or security chain, provided such devices are openable
from the inside without the use of a key or tool. 5.6. Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures. 6. 7. Doors serving roofs not intended to be
occupied shall be permitted to be locked, preventing entry to
the building from the roof. 8.Other than egress courts, where
occupants must egress from an exterior space through the
building for means of egress, exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following: 8.1.The maximum occupant load shall be posted
where required by Section 1004.9. Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways. 8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side. 8.3.The egress door locking
device is readily distinguishable as locked and shall be a key -
operated locking device. 8.4.A clear window or glazed door
opening, not less than 5 square feet (0.46 m2) in area, shall
be provided at each exit access door to determine if there are
occupants using the outdoor area. 8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating: THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on
the sign shall be not less than 1 inch (25.4 mm) high on a
contrasting background. 8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004. 9.Locking devices are
permitted on doors to balconies, decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet (23.23
m2) or less, serving a private office space.
Location: Main exit doors (west)
Comments: Install permanent signage "THIS DOOR -O REMAIN
UNLOCKED WHEN THIS SPACE IS OCCUPIED." Laminated paper will
not be accepted.
GENERATED ON 4/20/26, 3:41 PM 3 OF 8
GENERATED ON 4/20/26, 3:41 PM
4 OF 8
Fail
1010.2.4 - Locks and latches.
Locks and latches shall be permitted to prevent operation of
doors where any of the following exist: 1.Places of detention
or restraint. 2.In Group 1-1, Condition 2 and Group 1-2
occupancies where the clinical needs of persons receiving
care require containment or where persons receiving care
pose a security threat, provided that all clinical staff can
readily unlock doors at all times, and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times. 2. 3. In buildings in occupancy Group A
having an occupant Toad of 300 or less, Groups B, F, M and S,
and in places of religious worship, the main door or doors are
permitted to be equipped with key -operated locking devices
from the egress side provided: 2.1. 3.1. The locking device is
readily distinguishable as locked. 2.2. 3.2. A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch
(25 mm) high on a contrasting background. 2.3. 3.3. The use
of the key -operated locking device is revocable by the fire
code official for due cause. 3.4. Where egress doors are used
in pairs, approved automatic flush bolts shall be permitted to
be used, provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface -mounted
hardware. 4. 5. Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch, dead
bolt or security chain, provided such devices are openable
from the inside without the use of a key or tool. 5.6. Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures. 6. 7. Doors serving roofs not intended to be
occupied shall be permitted to be locked, preventing entry to
the building from the roof. 8.Other than egress courts, where
occupants must egress from an exterior space through the
building for means of egress, exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following: 8.1.The maximum occupant load shall be posted
where required by Section 1004.9. Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways. 8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side. 8.3.The egress door locking
device is readily distinguishable as locked and shall be a key -
operated locking device. 8.4.A clear window or glazed door
opening, not less than 5 square feet (0.46 m2) in area, shall
be provided at each exit access door to determine if there are
occupants using the outdoor area. 8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating: "THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on
the sign shall be not less than 1 inch (25.4 mm) high on a
contrasting background. 8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004. 9.Locking devices are
permitted on doors to balconies, decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet (23.23
m2) or less, serving a private office space.
Location: North exit door near diesel pumps
Comments: Install permanent signage "THIS DOOR TO REMAIN
UNLOCKED WHEN THIS SPACE IS OCCUPIED." Laminated paper will
not be accepted.
GENERATED ON 4/20/26, 3:41 PM 5 OF 8
Fail
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Emergency Equipment
Status Code
Fail
Fail
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not Tess than 90 minutes.
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Electrical Safety
Status Code
Fail
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Fail 603.2.2 - Unapproved conditionsOpen electrical terminations.
OOpen junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Fail
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Location: Waste cooking oil room near bathrooms
Comments: Licensed electrical contractor shall obtain permit and
inspection for outlet added, currently used for compressor.
Description
Location: North exit
Comments: Repair or replace exit sign that failed to illuminate during
test.
Location: Main exit (west)
Comments: Repair or replace exit sign that failed to illuminate during
test.
Description
Location: Near ATM machine/north exit door
Comments: Install missing outlet cover
Location: South exterior wall - Near dumpster
Comments: Install [Hissing outlet cover
Location: Behind bungee strap display
Comments: Properly mount power strip to avoid hanging by wires.
GENERATED ON 4/28/26, 3:41 PM
6 OF 8
Commercial Cooking Hood Suppression System
Status Code
Fail
606.3.3 - Cleaning.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be cleaned at intervals as required by
Sections 606.3.3.1 through 606.3.3.3.
Description
Location: Kitchen hood exhaust
Comments: Exhaust system cleaning 75 days past due as of 4120/26.
Provide cleaning and report to be uploaded to Compliance Engine
with any deficiencies corrected.