Loading...
HomeMy WebLinkAbout2424 RANCHERO RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/21/2026 05/26/2026 2026-00000436 $80.00 Customer #: 15371 CASEY'S GENERAL STORE #2867 1 SE CONVENIENCE BLVD ANKENY, IA 50021 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2424 RANCHERO RD - 04/20/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 15371 04/21/2026 05/26/2026 2026-00000436 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. I Waterloo Fire Rescue Inspection Report Casey's General Store #2867 aillillainimpet.DG 2867 Ranchero Rd, Waterloo IA 50701 INSPECTION DETAILS Inspec Lead Inspector BRAD BALDWIN Inspection Type Other Inspectors NIA 425 E. 3rd Street Inspection Number 16971 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 44 0 9 ®25 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/2012026 @ 15:20 $80 annual inspection fee BRAD BALDWIN - 04/20/2026 @ 15:38 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 04/20/2026 @ 15:39 Reinspection Date 05/12/2026 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 04/20/2026 @ 15:39 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Karri Dorsey 2026 CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 04/20/2026 GENERATED ON 4/20/26, 3:41 PM 1 OF 8 Additional Codes Status Code Description GENERATED ON 4/20/26, 3:41 PM 2 OF 8 Fail 1010.2.4 - Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exist: 1.Places of detention or restraint. 2.In Group 1-1, Condition 2 and Group 1-2 occupancies where the clinical needs of persons receiving care require containment or where persons receiving care pose a security threat, provided that all clinical staff can readily unlock doors at all times, and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times. 2. 3. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side provided: 2.1. 3.1. The locking device is readily distinguishable as locked. 2.2. 3.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch (25 min) high on a contrasting background. 2.3. 3.3. The use of the key -operated locking device is revocable by the fire code official for due cause. 3.4. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts does not have a doorknob or surface -mounted hardware. 4. 5. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool. 5.6. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures. 6. 7. Doors serving roofs not intended to be occupied shall be permitted to be locked, preventing entry to the building from the roof. 8.Other than egress courts, where occupants must egress from an exterior space through the building for means of egress, exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following: 8.1.The maximum occupant load shall be posted where required by Section 1004.9. Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways. 8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side. 8.3.The egress door locking device is readily distinguishable as locked and shall be a key - operated locking device. 8.4.A clear window or glazed door opening, not less than 5 square feet (0.46 m2) in area, shall be provided at each exit access door to determine if there are occupants using the outdoor area. 8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating: THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on the sign shall be not less than 1 inch (25.4 mm) high on a contrasting background. 8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004. 9.Locking devices are permitted on doors to balconies, decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet (23.23 m2) or less, serving a private office space. Location: Main exit doors (west) Comments: Install permanent signage "THIS DOOR -O REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." Laminated paper will not be accepted. GENERATED ON 4/20/26, 3:41 PM 3 OF 8 GENERATED ON 4/20/26, 3:41 PM 4 OF 8 Fail 1010.2.4 - Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exist: 1.Places of detention or restraint. 2.In Group 1-1, Condition 2 and Group 1-2 occupancies where the clinical needs of persons receiving care require containment or where persons receiving care pose a security threat, provided that all clinical staff can readily unlock doors at all times, and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times. 2. 3. In buildings in occupancy Group A having an occupant Toad of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side provided: 2.1. 3.1. The locking device is readily distinguishable as locked. 2.2. 3.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch (25 mm) high on a contrasting background. 2.3. 3.3. The use of the key -operated locking device is revocable by the fire code official for due cause. 3.4. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts does not have a doorknob or surface -mounted hardware. 4. 5. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool. 5.6. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures. 6. 7. Doors serving roofs not intended to be occupied shall be permitted to be locked, preventing entry to the building from the roof. 8.Other than egress courts, where occupants must egress from an exterior space through the building for means of egress, exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following: 8.1.The maximum occupant load shall be posted where required by Section 1004.9. Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways. 8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side. 8.3.The egress door locking device is readily distinguishable as locked and shall be a key - operated locking device. 8.4.A clear window or glazed door opening, not less than 5 square feet (0.46 m2) in area, shall be provided at each exit access door to determine if there are occupants using the outdoor area. 8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on the sign shall be not less than 1 inch (25.4 mm) high on a contrasting background. 8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004. 9.Locking devices are permitted on doors to balconies, decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet (23.23 m2) or less, serving a private office space. Location: North exit door near diesel pumps Comments: Install permanent signage "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." Laminated paper will not be accepted. GENERATED ON 4/20/26, 3:41 PM 5 OF 8 Fail 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Emergency Equipment Status Code Fail Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not Tess than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Waste cooking oil room near bathrooms Comments: Licensed electrical contractor shall obtain permit and inspection for outlet added, currently used for compressor. Description Location: North exit Comments: Repair or replace exit sign that failed to illuminate during test. Location: Main exit (west) Comments: Repair or replace exit sign that failed to illuminate during test. Description Location: Near ATM machine/north exit door Comments: Install missing outlet cover Location: South exterior wall - Near dumpster Comments: Install [Hissing outlet cover Location: Behind bungee strap display Comments: Properly mount power strip to avoid hanging by wires. GENERATED ON 4/28/26, 3:41 PM 6 OF 8 Commercial Cooking Hood Suppression System Status Code Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Description Location: Kitchen hood exhaust Comments: Exhaust system cleaning 75 days past due as of 4120/26. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. GENERATED ON 4/20/26, 3:41 PM 7 OF 8 P® FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 4/28/26, 3:41 PM 8 OF 8