Loading...
HomeMy WebLinkAbout2225 E SHAULIS RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/21/2026 05/26/2026 2026-00000440 $100.00 Customer #: 10030 LOST ISLAND WATER PARK 2225 E SHAULIS RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2225 E SHAULIS RD - 04/14/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # 10030 BILLING DATE DUE DATE INVOICE # CHARGES 04/21/2026 05/26/2026 2026-00000440 City of Waterloo Less Prepayment Total Due —� $100.00 $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 10030 cOost Waterloo Fire Rescue Inspection Report Lost Island Waterpark -111111111111111is RD, BLDG 2225 E Shaulis Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Lead Inspector BRAD BALDWIN Inspection Type Other Inspectors NIA 425 E. 3rd Street Inspection Number 16966 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 053 Passed codes NEXT STEPS 027 Failed codes 0 10 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/1412026 @ 11:19 $100 annual inspection fee BRAD BALDWIN - 04/15/2026 @ 16:24 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 05/05!2026 BRAD BALDWIN - 04115/2026 @ 16:24 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 0411512026 @ 16:24 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Jesse Henry CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 04/15/2026 GENERATED ON 4/15/26, 4:31 PM 1 OF 10 Means of Egress Status Code Fail Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Status Code Fail Fail Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Fire Alarm System Status Code Fail Chapter 14 - Inspection, testing, and maintenance Fire alarm system tested at least annually by licensed contractor Description Location: Gift shop storage room Comments: Remove all obstructions in path of egress to exit door. Location: Gift shop Comments: Remove all obstructions in path of egress to exit door. Description Location: Office east Comments: Repair or replace egress light above exit door. Location: Gift shop Comments: Repair or replace exit sign & egress lights combo that failed to illuminate during test. Location: Castaway Cafe Comments: Repair or replace exit signs (2) that failed to illuminate during test. Location: Go kart building Comments: Repair or replace exit signs & egress lights combos (2) that failed to illuminate during test Description Comments: Provide inspection report of fire alarm with any deficiencies corrected. Contractor must upload report to Compliance Engine. Due for inspection as of 4128126 GENERATED ON 4/15/26, 4:31 PM 2 OF 10 Additional Codes Status Code Fail Fail Fail Fail 2303.2 - Emergency disconnect switches. An approved emergency disconnect switch shall be provided at an approved location to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. The emergency disconnect switch for exterior fuel dispensers shall be provided with ready access and shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel -dispensing operations, the emergency disconnect switch shall be provided with ready access and be installed at an approved location. Such devices shall be distinctly labeled as: "EMERGENCY FUEL SHUTOFF." Signs shall be provided in approved locations. 2304.3.5 - Emergency procedures. An approved emergency procedures sign, in addition to the signs required by Section 2305.6, shall be posted in a conspicuous location and shall read: IN CASE OF FIRE, SPILL OR RELEASE 1.USE EMERGENCY PUMP SHUTOFF 2.REPORT THE ACCIDENT! FIRE DEPARTMENT TELEPHONE NO. FACILITY ADDRESS 2305.5 - Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill -pipe openings. 2305.6 - Warning signs. Warning signs shall be conspicuously posted within sight of each dispenser in the fuel -dispensing area and shall state the following: 1.No smoking. 2.Shut off motor. 3.Discharge your static electricity before fueling by touching a metal surface away from the nozzle. 4.To prevent static charge, do not reenter your vehicle while gasoline is pumping. 5.If a fire starts, do not remove nozzle —back away immediately. 6.It is unlawful and dangerous to dispense gasoline into unapproved containers. 7.No filling of portable containers in or on a motor vehicle. Place container on ground before filling. Description Location: Go-kart fueling station Comments: Provide inspector knowledge and location of emergency disconnect switch and signage of disconnect or have properly installed. Location: Go- kart fueling station Comments: Provide permanent required "Emergency Procedures" signage in compliance with code near station, laminated paper will not be accepted. Location: Go-kart fueling station Comments: Provide required sized fire extinguisher within 75 feet of tank/fueling station. Location: Go-kart fueling station Comments: Provide permanent required ' Warning" signage in compliance with code near station, laminated paper will not be accepted. GENERATED ON 4/15/26, 4:31 PM 3 OF 10 Fail Fail 0 5003.5 - Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above -ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. 507.5.3 - Private fire service mains and water tanks. Private fire service mains and water tanks shall be periodically inspected, tested and maintained in accordance with NFPA 25 at the following intervals: 1.Private fire hydrants of all types: Inspection annually and after each operation; flow test and maintenance annually. 2.Fire service main piping: Inspection of exposed, annually; flow test every 5 years. 3.Fire service main piping strainers: Inspection and maintenance after each use. Records of inspections, testing and maintenance shall be maintained. Location: Go-kart fueling tank Comments: Replace faded NFPA 704 hazard labeling on fuel tank as seen in photo attached. Location: All of property Comments: Provide annual inspection to all private hydrants, report of inspection including any deficiencies corrected shall be uploaded to Compliance Engine GENERATED ON 4/15/26, 4:31 PM 4 OF 10 Fail Fail 5704.2.3.2 - Label or placard. Tanks more than 100 gallons (379 L) in capacity, which are permanently installed or mounted and used for the storage of Class I, II or III liquids, shall bear a label and placard identifying the material therein. Placards shall be in accordance with NFPA 704. Exceptions: 1.Tanks of 300-gallon (1136 L) capacity or less located on private property and used for heating and cooking fuels in single-family dwellings. 2.Tanks located underground. 610.1.1- Installation. Clothes dryer exhaust duct systems shall be installed in accordance with the International Mechanical Code or the International Fuel Gas Code , and the manufacturer's installation instructions. Fire Service Features Sta:.us Code Fail 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. Location: Go-kart fueling tank Comments: Replace faded "Gasoline" identification labeling on tank. Location: Maintenance shop Comments: Mechanical contractor shall obtain permit and inspection to install dryer vent to discharge to the exterior air. Documentation of dryer vent cleaning shall be kept and provided to inspector annually. Description Location: Knox Box Comments: Keys have been changed, verify with inspector keys were updated in Knox Boxes. GENERATED ON 4/15/26, 4:31 PM 5 OF 10 Electrical Safety status Code Fail Fail Fail IX� Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 min) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Wave pool equipment room Comments: Provide missing outlet cover near blue filter tanks Location: South filter room basement Comments: Replace missing outlet cover on south wall Location: Calypso pool equipment room Comments: Replace missing outlet cover on south wall Location: Figi concession stand Comments: Replace missing outlet cover behind freezer Location: Go kart electric room Comments: Install missing outlet cover next to electric panels. Location: Go kart electric room Comments: Remove storage within 36" of electric equipment. GENERATED ON 4/15/26, 4:31 PM 6 of 10 Fail 603.6 • Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Sales east office Comments: Remove cord extending through wall to "cash room". GENERATED ON 4/15/26, 4:31 PM 7 OF 10 Portable Fire Extingusihers Status Code Description Fail 906.2 - General requirements. ', Portable fire extinguishers shall be selected, installed and Location: Tree Top Cafe maintained in accordance with this section and NFPA 10. Comments: Provide annual service to extinguisher, last recorded Exceptions: 1.The distance of travel to reach an extinguisher service completed April 2025 shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confine that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Molokini pump house Comments: Provide annual service to all extinguishers, last recorded service completed April 2025 GENERATED ON 4/15/26, 4:31 PM 8 OF 10 Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.i.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Location: Go kart building Comments: Provide annual service to all extinguishers, last recorded service completed April 2025 Location: Sulu concession stand Comments: Provide and install fire extinguisher on wall bracket GENERATED ON 4/15/26, 4:31 PM 9 OF 10 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 4/15/26, 4:31 PM 10 OF 10