Loading...
HomeMy WebLinkAbout1600 OLYMPIC DRIVECustomer #: 3311 SUNNYSIDE COUNTRY CLUB 1600 OLYMPIC DR WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/21/2026 05/26/2026 2026-00000435 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1600 OLYMPIC DR - 04/15/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # 3311 04/21/2026 05/26/2026 2026-00000435 Less Prepayment Total Due City of Waterloo CHARGES $100.00 $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. .1160 -41Now Waterloo Fire Rescue Inspection Report Sunnyside Country Club , BLDG 1600 Olympic Dr, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Lead Inspector BRAD BALDWIN Inspection Type 0111111111.1111111111110 Other Inspectors N/A 425 E. 3rd Street Inspection Number 16426 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 054 026 ®11 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/1612026 @ 07:26 $100 annual inspection fee BRAD BALDWIN - 04/1612026 @ 07:29 Reinspection Date 05/0712026 Annual sprinkler system inspection due 517126. Complete inspection with report uploaded by contractor to Compliance Engine including any deficiencies corrected. BRAD BALDWIN - 04/1712026 @ 14:54 All extinguishers shall be annually serviced, different dates of last recorded service noted throughout property. BRAD BALDWIN - 04/1712026 @ 14:56 Did not access pool equipment building during 4/15126 inspection. BRAD BALDWIN - 04/1712026 @ 15:14 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 04117/2026 @ 15:14 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 04/17/2026 @ 15:14 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 am. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature GENERATED ON 4/17/26, 3:16 PM 1 OF 15 Report completed post inspection Colin Kitson Date: CHECKLISTS 1E GENERATED ON 4/17/26, 3:16 PM 2 OF 15 Means of Egress Status Code Fail Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Description Location: Basement - Golf simulator area Comments: Simulator obstructing egress path to marked exit: Per City building Official Greg Ahlhelm, 2nd exit leading to interior hallway not required, approved to remove exit sign and properly cap electric wires in box with cover. Exit sign shall be installed above employee "Service Hallway" directing path of egress to hallway. Location: Basement exit path leading to golf simulator area Comments: As seen in photo attached: Remove store;ge and obstructions to clear path of egress to exit. GENERATED ON 4/17/26, 3:16 PM 3 OF 15 Additional Codes Status Code Fail 2303.2 - Emergency disconnect switches. An approved emergency disconnect switch shall be provided at an approved location to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. The emergency disconnect switch for exterior fuel dispensers shall be provided with ready access and shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel -dispensing operations, the emergency disconnect switch shall be provided with ready access and be installed at an approved location. Such devices shall be distinctly labeled as: "EMERGENCY FUEL SHUTOFF." Signs shall be provided in approved locations. Fail 2304.3.5 - Emergency procedures. An approved emergency procedures sign, in addition to the signs required by Section 2305.6, shall be posted in a conspicuous location and shall read: IN CASE OF FIRE, SPILL OR RELEASE 1.USE EMERGENCY PUMP SHUTOFF 2.REPORT THE ACCIDENT! FIRE DEPARTMENT TELEPHONE NO. FACILITY ADDRESS Fail 2305.6 - Warning signs. Warning signs shall be conspicuously posted within sight of each dispenser in the fuel -dispensing area and shall state the following: 1.No smoking. 2.Shut off motor. 3.Discharge your static electricity before fueling by touching a metal surface away from the nozzle. 4.To prevent static charge, do not reenter your vehicle while gasoline is pumping. 5.If a fire starts, do not remove nozzle —back away immediately. 6.It is unlawful and dangerous to dispense gasoline into unapproved containers. 7.No filling of portable containers in or on a motor vehicle. Place container on ground before filling. Description Location: Maintenance garage Comments: Provide permanent signage near interior emergency shut off switches and also on the exterior of building in approved location. Laminated paper will not be accepted. Location: Maintenance garage fueling tanks Comments: Provide permanent required Emergency Procedures signage in compliance with code near station, laminated paper will not be accepted. Location: Maintenance garage fueling tanks Comments: Provide permanent required "Warning" signage in compliance with code near station, laminated paper will not be accepted. GENERATED ON 4/17/26, 3:16 PM 4 OF 15 Fail Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: Basement utility room Comments: Remove obstructions to ready access to sprinkler riser room and electrical room. Maintain clear path at all times. Location: Pro Shop - Maintenance area Comments: Remove storage within 36" of sprinkler equipment, maintain clearance at all times. GENERATED ON 4/17/26, 3:16 PM 5 OF 15 Fail 5704.2.3.2 - Label or placard. Tanks more than 100 gallons (379 L) in capacity, which are permanently installed or mounted and used for the storage of Class I, II or III liquids, shall bear a label and placard identifying the material therein. Placards shall be in accordance with NFPA 704. Exceptions: 1.Tanks of 300-gallon (1136 L) capacity or less located on private property and used for heating and cooking fuels in single-family dwellings. 2.Tanks located underground. Fail Fail 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Location: Maintenance garage fueling station Comments: Replace faded "Gasoline" identification labeling on tank Location: Basement - Main bar Comments: Remove roller grill machine plugged to power strip. Heat producing appliances shall plug directly to a wall outlet Location: Maintenance garage - Employee area Comments: Remove microwave and coffee maker from plugged to extension cord and multi -plug adapter. Each appliance shall plug directly to wall outlet GENERATED ON 4:17/26, 3:16 PM 6 OF 15 Fail Fail 901.6 - Inspection, testing and maintenance. Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . 906.3 - Size and distribution. The size and distribution of portable fire extinguishers shall be in accordance with Sections 906.3.1 through 906.3.4. Location: Basement - Sprinkler Riser Room (near mean electric panels) Comments: Licensed sprinkler contractor shall make necessary repair on sprinkler leak. Location: Basement - Main bar area Comments: Maximum distance of travel of 75 feet access to extinguisher exceeded. Properly install extinguisher of required size on wall bracket between 4in - 5ft from the floor on war l bracket. Extinguisher shall be installed in a location that is accessible within 75 ft of the next nearest extinguisher. GENERATED ON 4/17/26, 3:16 PM 7 OF 15 Electrical Safety Status Code Description Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified Comments: Replace damaged outlet. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Kitchen near electric panels labeled "L8" Location: Colin's office Comments: Install missing outlet covers (2) GENERATED ON 4/17/26, 3:16 PM 8 OF 15 Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Basement - Main bar Comments: NW corner TV - Install missing outlet cover and remove multi -plug adapter. May replace adapter with properly mounted power strip with manual reset for low wattage electrical equipment only. Location: Basement - Gym Room Comments: Provide cover to box exposing wires on north wall. Location: Basement - Ladies locker room Comments: Install missing outlet cover behind sitting chair near lockers GENERATED ON 4/17/26, 3:16 PM 9 OF 15 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum dear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Panel "L1" near business office Comments: Remove storage within 36" of electric panel, maintain ready access to utilities at all times. Location: Pro Shop - Mechanical room Comments: Remove storage within 36" of electrical panel and maintain clear path of access at all times. GENERATED ON 4/17/26, 3:16 PM 10 OF 15 Fail Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System sta:us Coco Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Location: Boiler room - Below fire alarm panel Comments: Remove yellow extension cord. Location: Basement - Golf simulator Comments: Remove blue multi -use extension cord. Location: Maintenance garage - Office Comments: Remove extension cord plugged to printer. Description Location: Kitchen hood exhaust Comments: Exhaust system cleaning past due. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. GENERATED ON 4/17/26, 3:16 PM 11 OF 15 Fire Resistant Construction Maintenance Status Cede Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Basement - Main bar Comments: Replace missing ceiling tile west of bar above doorway GENERATED ON 4/17/26, 3:16 PM 12 OF 15 Portable Fire Extingusihers Slates COCI, Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Basement - Golf simulator area bar Comments: Class K fire extinguisher due for annual service by May 2026 GENERATED ON 4/17/26, 3:16 PM 13 OF 15 Fail O 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: Pro Shop Comments: Extinguisher shall be relocated to conspicuous, easily accessed location or a "Fire Extinguisher" sign installed above current location (See attachment) GENERATED ON 4/17/26, 3:16 PM 14 OF 15 Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 4/17/26, 3:16 PM 15 OF 15