Inspection Report 425 E. 3rd Street
Smitty's - 709 Jefferson ST, BLDG 709 Jefferson St - STE Open @1PM thurs and fri
otherwise 3, Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
04/21/2026 Annual Inspection (1Yr) 16498
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
033 07 036
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 0512812026
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 04123/2026 @ 12:15
S80 annual inspection fee
BRAD BALDWIN - 04/2812026 @ 07:24
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org -Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 04128/2026 @ 07:24
• Provide corrections to avoid progressive re-inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 04/28/2026 @ 07:24
• If all corrections are made before the scheduled re-inspection date, you can call to set up an earlier re-inspection. Normal operating hours for
inspections & re-inspections are Monday - Friday, 9:00 a.m. -4:00 p.m. *****Re inspection fees may be assessed for subsequent re-inspections. Re-
inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Justin Smith Date: BRAD BALDWIN 04/28/2026
CHECKLISTS
GENERATED ON 4/28/26, 7:26 AM 1 OF 6
Additional Codes
Code Description
Fail 5303.5.3-Securing compressed gas containers,cylinders
and tanks. Location:Bar and near back exit
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
r et
•
y`
•
4
•
GENERATED ON 4/28/26, 7:26 AN 2 OF 6
Electrical Safety
St at s Code Description
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:Above Beer Garden exit
prohibited.Approved covers shall be provided for all switch Comments:Licensed electrician shall properly connect wires in box
and electrical outlet boxes. with cover installed or wiring replaced.Receipt of work shall be kept
to show inspector
' "
s
Fail 603.5.3-Installation.
Relocatable power tap cords shall not extend through walls, Location:Bar-behind CO2 tanks
ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires.
to environmental or physical damage.
Fail 603.5.3-Installation.
Relocatable power tap cords shall not extend through walls, Location:Behind cooler near back walk-in fridge
ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires
to environmental or physical damage.
GENERATED ON 4/28/26, 7:26 AM 3 OF 6
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:Above back walk-in cooler
for permanent wiring and shall be listed and labeled in Comments:Remove yellow extension cord
accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
4, _
i.
ae.
fp
i `
--...,,,
-t
6' '
t 2
'Y
y-
i.- Z. a.
GENERATED ON 4/28/26, 7:26 AM 4 OF 6
Fail 603.6-Extension cords.
OExtension cords and flexible cordsshall not be a substitute Location:Near back walk-in cooler
for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord in corner plugged to
accordance with UL 817.Extension cords and flexible power strip
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
I
;k\ i
/
fA/
A
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
0 Portable fire extinguishers shall be selected,installed and Location:All extinguishers
maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,due for
Exceptions:1.The distance of travel to reach an extinguisher service as of April 2026
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
GENERATED ON 4/28/26, 7:26 AM 5 OF 6
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $80.00
Invoice Number Check Number Transaction Number
NIA N►A NIA
GENERATED ON 4/28/26, 7:26 AM 6 OF 6
O WA T� INVOICE DATE DUE DATE INVOICE# TOTAL DUE
'Pe 04/30/2026 06/05/2026 2026-00000447 $80.00
+ $ n 1'" n'1." •
0
35 7 1 I')
Customer#: 4458 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
SMITTY'S BAR 715 Mulberry St
709 JEFFERSON ST WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-709 JEFFERSON ST-04/21/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE ` DUE DATE INVOICE"# CHARGES
4458 04/30/2026 06/05/2026 2026-00000447 $80.00
Less Prepayment $0.00
Total Due—> $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.