Loading...
HomeMy WebLinkAbout709 JEFFERSON qb _GO 1/415-ie Waterloo Fire Rescue Nie Inspection Report 425 E. 3rd Street Smitty's - 709 Jefferson ST, BLDG 709 Jefferson St - STE Open @1PM thurs and fri otherwise 3, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 04/21/2026 Annual Inspection (1Yr) 16498 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 033 07 036 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0512812026 brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04123/2026 @ 12:15 S80 annual inspection fee BRAD BALDWIN - 04/2812026 @ 07:24 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org -Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 04128/2026 @ 07:24 • Provide corrections to avoid progressive re-inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 04/28/2026 @ 07:24 • If all corrections are made before the scheduled re-inspection date, you can call to set up an earlier re-inspection. Normal operating hours for inspections & re-inspections are Monday - Friday, 9:00 a.m. -4:00 p.m. *****Re inspection fees may be assessed for subsequent re-inspections. Re- inspection fees start at $100, then $150, and $200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Justin Smith Date: BRAD BALDWIN 04/28/2026 CHECKLISTS GENERATED ON 4/28/26, 7:26 AM 1 OF 6 Additional Codes Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Bar and near back exit Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. r et • y` • 4 • GENERATED ON 4/28/26, 7:26 AN 2 OF 6 Electrical Safety St at s Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Above Beer Garden exit prohibited.Approved covers shall be provided for all switch Comments:Licensed electrician shall properly connect wires in box and electrical outlet boxes. with cover installed or wiring replaced.Receipt of work shall be kept to show inspector ' " s Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Bar-behind CO2 tanks ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires. to environmental or physical damage. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Behind cooler near back walk-in fridge ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires to environmental or physical damage. GENERATED ON 4/28/26, 7:26 AM 3 OF 6 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Above back walk-in cooler for permanent wiring and shall be listed and labeled in Comments:Remove yellow extension cord accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. 4, _ i. ae. fp i ` --...,,, -t 6' ' t 2 'Y y- i.- Z. a. GENERATED ON 4/28/26, 7:26 AM 4 OF 6 Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Near back walk-in cooler for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord in corner plugged to accordance with UL 817.Extension cords and flexible power strip cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. I ;k\ i / fA/ A Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. 0 Portable fire extinguishers shall be selected,installed and Location:All extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguishers,due for Exceptions:1.The distance of travel to reach an extinguisher service as of April 2026 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 4/28/26, 7:26 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA N►A NIA GENERATED ON 4/28/26, 7:26 AM 6 OF 6 O WA T� INVOICE DATE DUE DATE INVOICE# TOTAL DUE 'Pe 04/30/2026 06/05/2026 2026-00000447 $80.00 + $ n 1'" n'1." • 0 35 7 1 I') Customer#: 4458 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SMITTY'S BAR 715 Mulberry St 709 JEFFERSON ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-709 JEFFERSON ST-04/21/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE ` DUE DATE INVOICE"# CHARGES 4458 04/30/2026 06/05/2026 2026-00000447 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.