HomeMy WebLinkAbout3910 UNIVERSITY AVENUE 408? 7d 4,,,TER(.00 Waterloo Fire Rescue " ffg Inspection Report 425 E.3rd Street 4,E HE', Waigreens - 3910 University AVE, BLDG 3910 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 04/28/2026 Annual Inspection (1Yr) 17941 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 045 Cog 21 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 05/27/2026 brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 04/29/2026 @ 08:12 • $80 annual inspection fee BRAD BALDWIN - 04/29/2026 @ 08:12 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org -Work: 319-291-4319 (#5) -Cell: 319-230-1224 BRAD BALDWIN - 04/29/2026 @ 08:12 • Provide corrections to avoid progressive re-inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN -04/29/2026 @ 08:12 • If all corrections are made before the scheduled re-inspection date, you can call to set up an earlier re-inspection. Normal operating hours for inspections & re-inspections are Monday - Friday, 9:00 a.m. -4:00 p.m. *****Re inspection fees may be assessed for subsequent re-inspections. Re- inspection fees start at$100, then $150, and $200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Carey Bass 2025 Date: BRAD BALDWIN 04/29/2026 CHECKLISTS GENERATED ON 4/29/26, 12:43 PM 1 OF 6 Means of Egress Starus Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Back storage area(west exit) The force for pushing or pulling open interior swinging Comments:Repair or replace egress exit door that failed to open with egress doors,other than fire doors,shall not exceed 5 less than 15lbs of force.Replacement of door requires building pounds(22 N).These forces do not apply to the force permit and inspection obtained. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:North exit near bathrooms The force for pushing or pulling open interior swinging Comments:Repair or replace egress exit door that failed to open with egress doors,other than fire doors,shall not exceed 5 less than 15lbs of force.Replacement of door requires building pounds(22 N).These forces do not apply to the force permit and inspection obtained. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. GENERATED ON 4/29/26, 12:43 PM 2 OF 6 Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. 0 Emergency power shall be provided for means of egress Location:Emergency egress lighting illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:All egress lights shall be tested and repaired if nonfunctional,provide documentation of all lighting working properly to inspector including signed and dated. Fail 1203.2.6-Exit signs. Ux Emergency power shall be provided for exit signs as required Location:All exit signage in Section 1013.6.3.The system shall be capable of powering Comments:All exit signs shall be tested and repaired if the required load for a duration of not less than 90 minutes. nonfunctional,provide documentation of all signage working properly to inspector including signed and dated. Fire Alarm System Status Code Description Fail Chapter 14-Inspection,testing,and maintenance 0 Fire alarm system tested at least annually by licensed Location:Fire alarm contractor Comments:Deficiencies noted in contractor report(Telgian Corp.) shall be corrected and repair report uploaded to Compliance Engine. See attachment of deficiencies. Fire Sprinkler System Status Code Description Fail 903.3.3-Obstructed locations. 0 Automatic sprinklers shall be installed with regard to Location:Above register check out obstructions that will delay activation or obstruct the water Comments:Clean dust and debris from sprinkler heads(2)above distribution pattern and shall be in accordance with the register. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 4/29/26, 12:43 PM 3 OF 6 Electrical Safety Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:West side of building(exterior) Identified electrical hazards shall be abated.Identified Comments:Licensed electrician shall make necessary repairs to hazardous electrical conditions in permanent wiring shall be damaged piping. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. f j j.. .Y: Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Pharmacy for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to dehumidifier. accordance with UL 817.Extension cords and flexible Appliance shall plug directly to permanent wall outlet.Adding new cordsshall not be affixed to structures,extended through outlet requires licensed electrician obtaining permit and inspection. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 4/29/26, 12:43 PM 4 OF 6 Additional Codes staws Code Description Fail 912.2.2-Existing buildings. On existing buildings,wherever the fire department Location:Front exterior of building(South) connection is not visible to approaching fire apparatus,the Comments:Permanent"FDC"sign including arrow pointing towards fire department connection shall be indicated by an approved west side of building shall be installed in an approved location. sign mounted on the street front or on the side of the Laminated paper will not be accepted.See attachment for example of building.Such sign shall have the letters"FDC"not less than signage. 6 inches(152 mm)high and words in letters not less than 2 inches(51 mm)high or an arrow to indicate the location. Such signs shall be subject to the approval of the fire code official. FDC GENERATED ON 4/29/26, 12:43 PM 5 OF 6 Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 4/29/26, 12:43 PM 6 OF 6 OF W q T� INVOICE DATE DUE DATE INVOICE ft TOTAL DUE 4)1, 04/30/2026 06/05/2026 2026-00000454 $80.00 • ...I."I '1 III'III*� • a ,"IF 0 4' "tvil Customer#: 21006 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WALGREENS DRUG STORE#3590 715 Mulberry St 3910 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-3910 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 04/28/2026- Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE' DUE DATE INVOICE# CHARGES 21006 04/30/2026 06/05/2026 2026-00000454 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.