Loading...
HomeMy WebLinkAbout1005 BLACK HAWK ROAD-BLACK HAWK TENNIS CLUB Waterloo Fire Rescue sPIN Inspection Report 425 E.3rd Street 4240 Black Hawk Tennis Club - 1005 Black Hawk RD, BLDG 1005 Black Hawk Rd, Waterloo IA 50701 -4 100— INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 05/04/2026 Annual Inspection (1Yr) 16944 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 035 0'' 13 ® 31 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 05126/2026 brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 05/05/2026 @ 09:43 • $100 annual inspection fee BRAD BALDWIN - 05/05/2026 @ 09:43 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org -Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 05/05/2026 @ 09:43 • Provide corrections to avoid progressive re-inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 05/05/2026 @ 09:43 • If all corrections are made before the scheduled re-inspection date, you can call to set up an earlier re-inspection. Normal operating hours for inspections & re-inspections are Monday - Friday, 9:00 a.m. -4:00 p.m. *****Re inspection fees may be assessed for subsequent re-inspections. Re- inspection fees start at $100, then $150, and $200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Chris Sagers Date: BRAD BALDWIN 05105/2026 CHECKLISTS GENERATED ON 5/5/26, 11:11 AM 1 OF / • Means of Egress Status Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open Odoors. Location:Court 4(east end) The force for pushing or pulling open interior swinging Comments:Repair or replace exit door that failed to open easily, egress doors,other than fire doors,shall not exceed 5 replacing door requires permit and inspection obtained. pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1010.1.3-Door opening force Forces to unlatch and open Odoors. Location:Court 2(east end) The force for pushing or pulling open interior swinging Comments:Repair or replace exit door that failed to open at all, egress doors,other than fire doors,shall not exceed 5 replacing door requires permit and inspection obtained. pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1032.2-Reliability. ORequired exit accesses,exits and exit discharges shall be Location:Court 5 continuously maintained free from obstructions or Comments:Remove extension ladder laying in exit path in front of impediments to full instant use in the case of fire or other door emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. GENERATED ON 5/5/26, 11:11 AN 2 OF 7 Additional Codes Status Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Main exit doors doors where any of the following exist:1.Places of detention Comments:Permanent approved signage shall be installed to doors or restraint.2.In Group I-1,Condition 2 and Group 1-2 (2)stating,"THIS DOOR SHALL REMAIN UNLOCKED DURING occupancies where the clinical needs of persons receiving BUSINESS HOURS" care require containment or where persons receiving care pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 5/5/26, 11:11 AN 3 OF Fail 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the Location: Clothes dryer vent exhaust duct system of a clothes dryer shall be maintained in Comments: Provide documentation of cleaning of dryer vent from accordance with the manufacturer's operating appliance to the outside of the building with signature and date. instructions to prevent the accumulation of lint or debris that Email documentation to fire inspector. prevents the exhaust of air and products of combustion. Emergency Equipment Status Code Description Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Court 2 (east end) illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: Egress light on exit sign damaged (hanging by wires) shall be repaired or replaced GENERATED ON 5/5/26, 11:11 AM 4 OF 7 Electrical Safety Status Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated.Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Court 4(west end) prohibited.Approved covers shall be provided for all switch Comments:Provide missing cover to box at wall/ceiling intersection and electrical outlet boxes. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. 0 Open junction boxes and open-wiring splices shall be Location:Outdoor tennis building prohibited.Approved covers shall be provided for all switch Comments:Light fixture near women's bathroom shall be repaired to and electrical outlet boxes. avoid hanging by wires and open to exterior elements 4 R> IV ilk r tp, �, myN �K 9 E em $'12116 v r Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Men's locker room entrance near Court 1 prohibited.Approved covers shall be provided for all switch Comments:Open wire connection above door missing cover shall be and electrical outlet boxes. corrected.If is exit sign or egress light,repair to proper working order GENERATED ON 5/5/26, 11:11 AM 5 OF 7 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Comments:Annual service to all extinguishers due June 2026 maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 13,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Outdoor tennis building and volleyball shack maintained in accordance with this section and NFPA 10. Comments:Was not given access to inspect on 514126.Provide Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 inspector access to inspect on scheduled re-inspection or call to set up separate time. occupancies.2.Thirty-0ay inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Court 2(west) shall be installed on the hangers or brackets supplied. Comments:Extinguisher currently sitting on ground,bracket missing Hangers or brackets shall be securely anchored to the from wall.Discussed moving extinguisher AND signage closer to mounting surface in accordance with the manufacturer's post to protect from being bumped off the wall installation instructions. GENERATED ON 5/5/26, 11:11 NI 6 of 7 Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA 7 OF 7 GENERATED ON 5/5/26, 11:11 AM OF WA rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE I. // 0 05/18/2026 06/23/2026 2026-00000461 $100.00 u .,aiv�••. !A o 4w • O SS1 d 11‘ Customer#: 4653 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BLACK HAWK TENNIS CLUB 715 Mulberry St PO BOX 26 WATERLOO, IA 50703 WATERLOO, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1005 BLACK HAWK RD - FOR BILLING INQUIRY: (319)291-4323 05/04/2026 Description Total Price INSPECTION 2,000 HH $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4653 05/18/2026 06/23/2026 2026-00000461 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. OF W A . INVOICE DATE DUE DATE INVOICE# TOTAL DUE to 05/20/2025 06/25/2025 2025-00000353 $100.00 • . O Customer#: 4653 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BLACK HAWK TENNIS CLUB 715 Mulberry St PO BOX 26 WATERLOO, IA 50703 WATERLOO, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1005 BLACK HAWK RD- 5-5-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4653 05/20/2025 06/25/2025 2025-00000353 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.