HomeMy WebLinkAbout3362 UNIVERSITY AVENUE-PATHWAYS B EHAVIORAL SERVICES Waterloo Fire Rescue '"1 Inspection Report�;� p p 425 E.3rd Street 44100 Pathways Behavioral Services-3362 University AVE,BLDG 3362 University Ave, Waterloo IA 50701 INSPECTION DETAILS W64) 4 it:0_ Inspection Date Inspection Type Inspection Number 05111/2026 Annual Inspection(1Yr) 22242 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 058 018 08 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0611012026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0511112026 @ 10:50 $100 annual inspection fee BRAD BALDWIN-0511112026 @ 10:50 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-0511112026 @ 10:51 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature I �7 Report completed post inspection I—�\ Matt Flarrety 2026 Date: BRAD BALDWIN 0511212026 CHECKLISTS GENERATED ON 5/12/26, 7:20 AM 1 OF 7 Emergency Equipment Stat.is Code Description Fail 1103.9-Carbon monoxide alarmsdetection. Carbon monoxide alarms detection shall be installed in Location:Residential side Room#4 existing dwelling units and sleeping units Group I-1,1-2,1-4 Comments:Repair or replace carbon monoxide detector that failed and R occupancies and in classrooms in Group E test during inspection. occupancies where those units include any of the conditions identified in Sections 915.1.2 through 915.1.6.The carbon monoxide alarms shall be installed in the locations specified in Section 915.2 and the installation shall be in accordance with Section 915.4.Exceptions:1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided.2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source.3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. Fail 1103.9-Carbon monoxide alarmsdetection. Carbon monoxide alarms detection shall be installed in Location:Residential side Room#3 existing dwelling units and sleeping units Group 1-1,1-2,1-4 Comments:Replace missing carbon monoxide detector with properly and R occupancies and in classrooms in Group E operating detector. occupancies where those units include any of the conditions identified in Sections 915.1.2 through 915.1.6.The carbon monoxide alarms shall be installed in the locations specified in Section 915.2 and the installation shall be in accordance with Section 915.4.Exceptions:1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided.2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source.3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. Fail 1103.9-Carbon monoxide alarrsdetection. Carbon monoxide alarms detection shall be installed in Location:Residential side Room#2 existing dwelling units and sleeping units Group I-1,1-2,1-4 Comments:Replace missing carbon monoxide detector with properly and R occupancies and in classrooms in Group E operating detector. occupancies where those units include any of the conditions identified in Sections 915.1.2 through 915.1.6.The carbon monoxide alarms shall be installed in the locations specified in Section 915.2 and the installation shall be in accordance with Section 915.4.Exceptions:1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided.2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source.3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. GENERATED ON 5/12/26, 7:20 AM 2 OF 7 Fire Sprinkler System Status Code oescnpr:on Fail 5.2.1.1.5-Missing escutcheons Escutcheons and coverplates for recessed,flush,and Location:Residential side women's bathroom concealed sprinklers shall be replaced if found missing Comments:Loose escutcheon shall be corrected to be installed tight during the inspection. to ceiling Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side men's bathroom obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the Comments:Remove dust and debris from sprinkler head applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side women's bathroom obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be Installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side Room#4 obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side Room#3 obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 5/12/26, 7:20 AN OF 7 Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side Room#2 obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Residential side Room#1 obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Electrical Safety sr,tr,; Code Description Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Vicki Mueller's Office for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to power strip.Power accordance with UL 817.Extension cords and flexible strip must also plug directly to wall outlet and be supported to avoid cordsshall not be affixed to structures,extended through hanging by wires. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Ox Extension cords and flexible cordsshall not be a substitute Location:Basement maintenance office for permanent wiring and shall be listed and labeled in Comments:Remove flexible cords(2)extending above drop ceiling. accordance with UL 817.Extension cords and flexible Cords shall not pass through a concealed space. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Additional Codes Status Code Description Fail 610.1.2-Maintenance. Ox The lint trap,mechanical and heating components,and the Location:Laundry dryer vent exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning of dryer vent from accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that appliance to the outside of the building with signature and date. Email documentation to fire inspector. prevents the exhaust of air and products of combustion. GENERATED ON 5/12/26, 7:20 AM 4 OF 7 Fire Resistant Construction Maintenance Status Code Description Fail 705.2.4 - Door operation. OSwinging fire doors shall close from the full-open position Location: Residential side men's bathroom and latch automatically. Comments: Repair or replace door that failed to self-shut and latch during inspection. Replacement of door requires permit and inspection obtained. Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full-open position Location: Residential side women's bathroom and latch automatically. Comments: Repair or replace door that failed to self-shut and latch during inspection. Replacement of door requires permit and inspection obtained. Fail 705.2.6 -Testing. 0 Horizontal and vertical sliding and rolling fire doors shall be Location: Kitchen rolling fire door inspected and tested annually to confirm proper operation Comments: Testing of door overdue: Provide documentation from and full closure. Records of inspections and testing shall be testing agency documenting annual inspection. Report may be maintained. emailed to fire inspector GENERATED ON 5/12/26, 7:20 AM 5 OF 7 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. OPortable fire extinguishers shall be selected,installed and Location:IT Server room maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,last recorded Exceptions:1.The distance of travel to reach an extinguisher service completed December 2024 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. Cj Portable fire extinguishers shall be selected,installed and Location:Basement elevator service room maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,last recorded Exceptions:1.The distance of travel to reach an extinguisher service completed December 2024 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 5/12/26, 7:20 AM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA 7OF 7 GENERATED ON 5/12/26, 7:20 AM OF W A 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE APe 05/18/2026 06/23/2026 2026-00000482 $100.00 is volo Customer#: 9962 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PATHWAYS BEHAVIORAL SERVICES INC 715 Mulberry St 3362 UNIVERSITY AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3362 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 05/11/2026 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9962 05/18/2026 06/23/2026 2026-00000482 $100.00 Less Prepayment $0.00 Total Due -+ $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.