HomeMy WebLinkAboutWaterloo Water Works 2026 Heartland Hills Area Phase 4 Addendum 1 060826ADDENDUM NO. 1
TO THE BIDDING DOCUMENTS FOR THE
2026 HEARTLAND HILLS AREA PHASE 4 WATER MAIN REPLACEMENT PROJECT
WATERLOO WATER WORKS,
WATERLOO, IA
DATE: June 8, 2026
BID DUE DATE AND TIME: 10:30 AM, June 16, 2026
TO ALL BIDDERS ON THE ABOVE PROJECT:
1. Replace Sheets 3, 16, 17 and 18 of the Construction Plans with the attached Sheets 3, 16, 17
and 18. This revises HDD #8 and adds HDD #11 plus other changes to the open trench
construction along Huntington Rd.
2. Replace the FORM OF BID OR PROPOSAL of the Construction Specifications with the
attached FORM OF BID OR PROPOSAL. This adds Bid Item 445 for HDD #11 and revises
the estimate quantity for Bid Item 418
Any revisions to any of the Contract Documents made by this Addendum shall be considered as
the same revision to any and all related areas of the Contract Documents not specifically called
out in this Addendum.
The bidder shall acknowledge receipt of this Addendum by inserting the number and date in the
spaces provided in the Form of Bid or Proposal, Item 6, Page 7 of 8.
William J. Claassen, P. E.
ADDENDUM NO. 1 2026 Heartland Hills Area Phase 4 Water main Replacement Page 1 of 13
FORM OF BID OR PROPOSAL
2026 PHASE 4 HEARTLAND HILLS AREA WATER MAIN REPLACEMENT
WATERLOO WATER WORKS,
WATERLOO, IA
General Manager and Board of Trustees
Waterloo Water Works
Waterloo, Iowa
1. The undersigned, being a Corporation existing under the laws of the State of ,
a Partnership consisting of the following partners:
, having familiarized (himself) (themselves) (itself) with the existing
conditions on the project area affecting the cost of the work, and with all the contract documents
listed in the Table of Contents and Addenda (if any), as prepared by Wayne Claassen Engineering
and Surveying, Inc. are now on file in the office of the General Manager of the Waterloo Water
Works, Waterloo, Iowa, hereby proposes to furnish all supervision, technical personnel, labor,
materials, machinery, tools, appurtenances, equipment, and services, including utility and
transportation services required to construct and complete this 2026 PHASE 4 HEARTLAND
HILLS AREA WATER MAIN REPLACEMENT project, all in accordance with the above -
listed documents and for the unit prices for work in place for the following items and quantities:
BASE BID
ITEM EST. UNIT TOTAL
NO. DESCRIPTION UNIT QTY. PRICE PRICE
001. Mobilization L.S.. 1
002. Seed, Fertilize, and Mulch by AC. 1
Hydroseeding (IDOT Urban Mix)
003. 9" Dia., Straw Filled Wattles L.F. 2,175
004. Inlet Protection, SUDAS 9040 EA.. 24
005. Traffic Control L.S. L.S.
006. Maintenance Bond, 2-Year L.S. L.S.
401. HDD #1 Water Main,
C900 DR18 PVC, 8 inch
Directionally Drilled L.S. L.S.
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 1 OF 8
ITEM EST. UNIT
NO. DESCRIPTION UNIT QTY. PRICE
402. HDD #2 Water Main, C900 DR18
PVC, 8-inch Directionally Drilled L.S. L.S.
403. HDD #3 Water main, C900 DR18
PVC, 8-inch Directionally Drilled. LS. LS
404. HDD #4 Water main C900. DR18
PVC 8-inch Directionally Drilled LS LS
405. HDD #5 Water Main CR900 DR 18
8-inch Carrier Pipe in 12-INCH DR18
C900 PVC Casing Pipe
L.S. LS
406.
HDD #6 Water Main C900 DR 18
PVC, 8- inch Directionally Drilled
LS LS
407.
HDD #7 Water Main C900 DR18
PVC 12-INCH Carrier Pipe
In 16- inch DR 18 C900 PVC
Casing Pipe
LS LS.
408.
HDD # 8 Water Main, C900 DR18
PVC 12- inch Directionally Drilled
LS LS
409.
HDD #9 Water Main, C900 DR18
PVC 12- inch Directionally Drilled
LS. LS
410.
HDD #10 Water Main, C900 DR18
PVC 16- inch Directionally Drilled
LS LS
411.
Connection of new 8" dia., PVC Water Main
To new 8" PVC Water Main
EA 5
412.
Connection of new 8" dia., PVC Water Main.
To existing 8" PVC Water Main
EA. 5
TOTAL
PRICE
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 2 OF 8
ITEM EST. UNIT TOTAL
NO. DESCRIPTION UNIT QTY. PRICE PRICE
413. Connection of new 8" dia., PVC Water Main
To new 12" PVC Water Main
EA. 3
414.
Connection of new 12" dia. PVC
Water Main to new 16" PVC Water Main
EA 1
415.
Connection of new 12" dia. PVC
Water Main to existing 12" C.I.P/D.I. P
Water Main
EA 1
416.
Water Main 8" dia., C900 DR18
PVC by Open Trench Construction
LF 347
417.
Water Main 8" dia., D.I.P.
With Nitrile Gaskets
LF 367
418.
Water Main 12" dia., C900 DR18
PVC by open Trenched Construction
LF 651
419.
Water Main 16" dia., C900 DR 18.
PVC by Open Trenched Construction
LF 120
420.
Tee, 8" dia. by 8" dia., D.I.P.
Complete with Thrust Restraint
EA 5
421.
Tee, 12" dia., by 8" dia. D.I.P.
Complete with Thrust Restraint
EA 2
422.
Tee, 16" dia., by 12" dia. D.I.P
Complete with Thrust Restraint
EA 2
423.
Bend, 90 Degree, 12" dia., Ductile Iron,
Complete with Thrust Restraint
EA 1
424.
Bend, 45 Degree, 12" dia., Ductile Iron,
Complete with Thrust Restraint
EA 2
425.
Bend, 11.25 Degree, 12" dia., Ductile Iron
Complete with Thrust Restraint
EA 2
426.
Cross, 8" dia., by 8" dia. D.I.P.
Complete with Thrust Restraint
EA 1
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement
PAGE 3 OF 8
ITEM
NO. DESCRIPTION
427. Cross 12" dia., by 8" dia. D.I.P.
Complete with Thrust Restraint
428. End Cap 16" dia.
Complete with Thrust Restraint
429. Reducer, 8" by 6" dia., D.I.P.
Complete with Thrust restraint
430. Install New Fire Hydrant Assembly
M.J., 6.5' Bury Complete
431. Remove and Salvage
Existing Fire Hydrant Assembly
Complete
432. Gate Valve, 8" dia. M.J. with
Valve Box and Mechanical
Thrust Restraint
433. Gate Valve, 12" dia. M.J. with
Valve Box and Mechanical
Thrust Restraint
434. Gate Valve, 16" dia. M.J. with
Valve Box and Mechanical
Thrust Restraint
435. Water Service Connection,
New 1" dia. Complete
436. Water Service Connection, to existing
Water Services Line 1" dia., Complete
437. Water Service Connection, 1" dia.,
By Open -Cut Excavation
438. Water Service Connection, 1" dia.,
By Directional Drilling
EST. UNIT
UNIT QTY. PRICE
EA 1
EA 2
EA. 2.
EA. 14
EA. 11
EA. 14
EA. 6
EA. 3
EA. 50
EA. 34
LF. 439
LF. 811
TOTAL
PRICE
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 4 OF 8
ITEM EST. UNIT
NO. DESCRIPTION UNIT QTY. PRICE
439. Fill Existing 6" dia. Water Main
With Cellular Concrete
LF 3,642
440.
Fill Existing 12" dia. Water Main
With Cellular Concrete
LF 1,998
441.
Omit
442.
Link Seals between 8" PVC Carrier
Pipe and 12" PVC Casing Pipe
Water Tight, Complete
EA. 6
443.
Link Seals between 12" PVC Carrier
Pipe and 16" PVC Casing Pipe
Water Tight, Complete
EA. 4
444.
Hydrant Bags, Furnish, Install and Maintain
EA 32
445.
HDD #11 Water Main, C900 DR18
PVC 12- inch Directionally Drilled
LS LS
501.
Remove / Replace Existing HMA Street
Pavement Including Curb and Gutter
S.Y. 380
502.
Remove / Replace Existing PCC
Driveway Pavement
S.Y. 105
503.
Remove / Replace Existing PCC t
Sidewalk 4" Thick
S.Y. 430
504.
ADA Inserts
EA 5
TOTAL BASE BID
TOTAL
PRICE
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 5 OF 8
ITEM
NO. DESCRIPTION
001-A. Mobilization
002-A.
Seed, Fertilize, and Mulch by
Hydroseeding (IDOT Urban Mix)
003-A.
9" Dia., Straw Filled Wattles
004-A .
Traffic Control
005-A .
Maintenance Bond, 2-Year
416-A .
Connection of New 16" dia.
PVC Water Main to Existing
16" C.I.P/D.I.P Water Main
419-A.
Water Main 16" dia., CR900 DR 18.
PVC by open Trench Construction
424-A.
Bend, 45 ❑, 16" dia., Ductile Iron,
Complete with Thrust Restraint
425-A .
Bend, 22.5, 16" dia., Ductile Iron.
Complete with Thrust Restraint
427-A .
End Cap 16" dia.
Complete with Thrust Restraint
429-A.
Install New Fire Hydrant Assembly
M.J., 6.5' Bury Complete
433-A.
Gate Valve, 16" dia. M.J. with
Valve Box and Mechanical
Thrust Restraint
440-A.
Water Main, Insulate
EST. UNIT TOTAL
UNIT QTY. PRICE PRICE
LS 1
AC. 1
L.F. 1,070
L.S. L.S.
L.S. L.S.
EA 2
LF 966
EA 4
EA 2
EA 1
EA. 2
EA. 1
LF 24
TOTAL ALTERNATE A BID
TOTAL BASE BID PLUS ALTERNATE A BID
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 6 OF 8
2. It is understood that the quantities set forth are approximate only and subject to variation and that the
unit bid price for the work done shall govern in the actual payment to Contractor.
3. In submitting this bid, the bidder understands that the right is reserved by the Waterloo Water Works
to reject any or all bids. If written notice of the acceptance of this bid is mailed, telegraphed, or
delivered to the undersigned within thirty (30) days after the opening thereof, or at any time thereafter
before this bid is withdrawn, the undersigned agrees to execute and deliver an agreement in the
prescribed form and furnish the required bond and certificate of the insurance within ten (10) days after
the agreement is presented to him for signature, and start work within ten (10) days after "Notice to
Proceed" is issued.
4. Security in the sum of Dc
($ ) in the form of , is submitted herewith in
accordance with the INSTRUCTIONS TO BIDDERS
5. The bidder is prepared to submit a financial and experience statement upon request.
6. The bidder has received the following Addendum or Addenda:
Addendum No. Date
7. The bidder has filled in all blanks on this proposal.
8. The bidder has attached all applicable forms.
9. The Owner reserves the right to select alternates, delete line items, and/or to reduce quantities prior
to the award of a contract due to budgetary limitations.
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 7 OF 8
(Name of Bidder)
BY: Ti
Official Address: (Including Zip Code):
I.R.S. No.
(Date)
FORM OF BID 2026 Phase 4 Heartland Hills Area,
Water Main Replacement PAGE 8 OF 8
Base Bid Bid Reference Notes
001. MOBILIZATION
ITEM INCLUDES MOBILIZING ALL EQUIPMENT, LABOR AND MATERIALS TO THE SITE FOR
ALL ASPECTS OF THE PROJECT, IRREGARDLESS OF HOW MANY MOBILIZATIONS ARE
NECESSARY TO COMPLETE THE PROJECT,
002. SEED FERTILIZE. AND MULCH (]DOT URBAN MIX) BY HYDROSEEDING
BID PRICE SHALL INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SEED, FERTILIZING, MULCHING
AND OTHER ITEMS NEEDED FOR COMPLETION IN CONFORMANCE WITH ARTICLE 2601 OF THE
]DOT STANDARD SPECIFICATIONS. ITEM IS TO BE COMPLETED BY HYDRO -SEEDING. ALL
DISTURBED AREAS EXCEPT FOR PAVED AREAS ARE INCLUDED IN THIS ITEM. ITEM TO BE
COMPLETED WITHIN 21 CALENDAR DAYS AFTER NEW WATER SERVICES AND REPACEMENT
PAVING HAS BEEN COMPLETED.
003. 9" DIA.. STRAW FILLED WATTLES
004. INLET PROTECTION. SUDAS 9040
ONLY ITEMS INSTALLED AND MAINTAINED AND MEASURED FOR PAYMENT FOR EROSION
CONTROL AT BACK OF CURBS, EDGES OF PAVEMENT AND ALONG DRAINAGE WAYS AND FOR
INLET PROTECTION, AS SHOWN IN THESE PLANS, WILL BE MEASURED FOR PAYMENT BY THE
WWW.
ITEMS INSTALLED FOR EROSION CONTROL AT EXCAVATION STOCKPILE AREAS ARE SOLELY
THE CONTRACTOR'S RESPONSIBILITY AND WILL NOT BE PAID FOR BY THE WWW. SAID WORK
SHALL BE INCIDENTAL TO THE THE CONTRACT AND SHALL NOT BE PAID FOR BY THE WWW.
ALL OF SAID WORK SHALL BE INSTALLED WITHIN 24 HOURS OF THE TIME FIRST INSTRUCTED
BY THE OWNER'S REPRESENTATIVE.
005. TRAFFIC CONTROL
BID PRICE SHALL INCLUDE ALL LABOR, EQUIPMENT, FLAGGERS, SIGNS, BARRICADES AND
APPURTENANT ITEMS NEEDED FOR TRAFFIC CONTROL,
THE I.D.D,T, CURRENT SPECIFICATIONS SHALL APPLY TO ALL TRAFFIC CONTROL, PAY
WILL BE BY LUMP SUM PAYMENT FOR EVERYTHING NEEDED TO CARRY OUT TRAFFIC
CONTROL ON THIS PROJECT, THE CONTRACTOR SHALL BE ENTIRELY RESPONSIBLE FOR
THE SAFETY AND PROPER TRAFFIC CONTROL WITHOUT FURTHER
DIRECTION FROM THE
ENGINEER OR INSPECTOR.
CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SIGNS AND FLASHERS
THROUGHOUT THE ENTIRE TIME THEY ARE IN PLACE.
CONTRATOR'S WORK SHALL BE COMPLETED IN A MANNER THAT DOES NOT CLOSE
STREETS COMPLETELY TO TRAFFIC, WITHOUT PRIOR WRITTEN APPROVAL AND 24 HOUR
NOTICE TO ALL AFFECTED RESIDENTS, ALL EQUIPMENT WITHIN ROADWAY AREAS SHALL
BE REMOVED AND ALL EXCAVATIONS WITHIN ROADWAY SECTIONS SHALL BE
BACKFILLED TO SAFELY ALLOW THRU TRAFFIC BETWEEN 1 HOUR BEFORE SUNSET AND
ONE HOUR AFTER SUNRISE EVERY DAY,
CONTRACTOR SHALL SUBMIT HIS/HER PROPOSED TRAFFIC CONTROL PLAN TO THE
ENGINEER FOR APPROVAL PRIOR TO THE PRE -CONSTRUCTION CONFERENCE,
006. MAINTENANCE BOND 2-YEAR
ITEM INCLUDES PROVIDING A TWO-YEAR MAINTENANCE BOND TO THE WATERLOO WATER
WORKS FOR ALL WORK PERFORMED BY THE CONTRACTOR AND HIS/HER
SUBCONTRACTORS ON THIS PROJECT,
SAID BOND SHALL BE OF A FORM THAT IS ACCEPTABLE TO THE WATERLOO WATER
WORKS. SAID TWO YEAR PERIOD SHALL BEGIN AFTER THE PROJECT IMPROVEMENTS ARE
ACCEPTED BY THE WATERLOO WATER WORKS.
401. HDD Al WATER MAIN, C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED
402. HDD #2 WATER MAIN, C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED
403_ HDD #3 WATER MAIN, C900 DR18 PVC, B-INCH DIRECTIONALLY DRILLED
404. HDD #4 WATER MAIN, C900 DR18 PVC. 8-INCH DIRECTIONALLY DRILLED
405. HDD #5 WATER MAIN, C900 DR18 PVC, 8-INCH CARRIER PIPE IN 12-INCH DR18 C900 PVC CASING PIPE
406. HDD #6 WATER MAIN, C900 DR18 PVC. 8-INCH DIRECTIONALLY DRILLED
407. HOD#7 WATER MAIN, C900 DR18 PVC, 12-INCH CARRIER PIPE IN 16-INCH DR18 C900 PVC CASING PIPE
408. HDD ;Y8 WATER MAIN. C900 DR18 PVC. 12-INCH DIRECTIONALLY DRILLED
409. HDD #9 WATER MAIN. C900 DR18 PVC. 12-INCH DIRECTIONALLY DRILLED
410. HDD #10 WATER MAIN, C900 DR18 PVC, 16-INCH DIRECTIONALLY DRILLED
445. HDD #11 WATER MAIN, C900 DR18 PVC. 12-INCH DIRECTIONALLY DRILLED
BID PRICE SHALL INCLUDE ALL MATERIALS AND EQUIPMENT NECESSARY TO INSTALL DR 18 AWWA
C-900/RJ RESTRAINED JOINT PVC WATER MAIN BY DIRECTIONAL DRILUNG OF THE SIZE NOTED IN THE
PLANS. PIPE SHALL BE CERTA-LOK BY CERTAINTEED OR APPROVED EQUAL WITH STANDARD STYRENE
BUTADIENE RUBBER GASKETS. ITEM INCLUDES TWO COPPERHEAD COPPER CLAD STEEL OR APPROVED
EQUAL TRACING WIRES.
BID PRICE INCLUDES ALL WATER MAIN HDDS ON THE PARTICULAR STREET AS INDICATED ON THE PLANS
AND/OR AS MAY BE NECESSARY TO COMPLETELY INSTALL THE NEW WATER MAIN ON THE PARTICULAR
STREET.
DRILLING FLUIDS SHALL BE CONTAINED TEMPORARILY WITHIN THE STREET RIGHT-OF-WAY, COLLECTED
AND HAULED OFF -SITE TO AN APPROVED DISPOSAL AREA AT NO ADDITIONAL COST TO THE WATER
WORKS.
ITEM INCLUDES BACTERIOLOGICAL, PRESSURE, AND LEAKAGE TESTING AND ALL OTHER ITEMS NECESSARY
TO COMPLETE THIS CONSTRUCTION AND TO PROVIDE A PROPERLY OPERATING WATER MAIN. THE
CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR NECESSARY FOR TESTING THE
WATER MAIN. THIS SHALL INCLUDE RESTRAINED JOINTS ON PIPE AND FITTINGS AT DEADENDS, PLUGS,
PIPE AND CORP STOPS OF SUFFICIENT SIZE FOR FLUSHING AFTER TESTING. ALL TESTS SHALL BE
CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION.
WATER MAIN TO BE DISINFECTED, FLUSHED AND TESTED FOR BACTERIA AND CHLORINE PRIOR TO
HYDROSTATIC TESTING. TWO CONSECUTIVE BACTERIOLOGICAL TESTS MUST PASS AT 24 HOUR MINIMUM
INTERVALS TO BE ACCEPTED AS PASSING.
PRESSURE TEST SHALL BE 1 1/2 TIMES NORMAL WORKING PRESSURE, BUT NOT LESS THAN 150 P.S.I.
ALL SECTIONS OF AWWA STANDARD 651 SHALL APPLY, INCLUDING SECTION 4.6, WHICH IS NOT
OPTIONAL NEW WATER MAIN SHALL BE ISOLATED FROM THE EXISTING WATER MAIN UNTIL ACCEPTANCE
OF THE PRESSURE, LEAK AND BACTERIOLOGICAL TESTING OF EACH SEGMENT OF NEW MAIN.
ITEM INCLUDES SHOCK DISINFECTING THE EXISTING HYDRANTS AND PIPING TO BE RE -LOCATED WITH
CONCENTRATED SOLUTIONS AS PER AWWA C651, SEC.4.7, INCLUDING SEC. 4.7.4 AND SEC 4.7.5.
401. HDD i1 WATER MAIN. C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED (CONTNUED)
402. HDD #2 WATER MAIN. C900 DR18 PVC. 8-INCH DIRECTIONALLY DRILLED (CONTNUED)
403. HDD #3 WATER MAIN, C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED (CONTNUED)
404. HDD k4 WATER MAIN C900 DR18 PVC, 8-INCH DIREC11ONALLY DRILLED (CONTNUED)
405. HDD 95 WATER MAIN, C900 DR18 PVC, 8-INCH CARRIER PIPE IN 12-INCH DR18 C900 PVC
CASING PIPE (CONTNUED)
406. HDD 46 WATER MAIN. C900 DR18 PVC. B-INCH DIRECTIONALLY DRILLED (CONTNUED)
407. HDD 07 WATER MAIN, C900 DR18 PVC- 12-INCH -ARRI R PIPE IN 16-INCH DR18 C900 PV -
CASING PIPE (CONTNUED)
408. HOD #e WATER MAIN. C900 DR18 PVC. 12-INCH DIRECTIONALLY DRILLED (CONTNUED)
409. HDD #9 WATER MAIN. C900 DR18 PVC. 12-INCH DIRECTIONALLY DRILLED (CONTNUED)
410. HDD A10 WATER MAIN. C900 DR18 PVC. 16-INCH DIRECTIONALLY DRILLED (CONTNUED)
445. HDD #11 WATER MAIN. C900 DRIB PVC 12-INCH DIRECTIONALLY DRILLED (CONTNUED)
WATER FOR FILLING, FLUSHING AND TESTING WATER MAINS SHALL BE FURNISHED BY
THE WATERLOO WATER WORKS AT NO COST TO THE CONTRACTOR UNLESS THE NEW
WATER MAIN DOES NOT PASS TESTING ON THE FIRST TRIAL. IF THE WATER MAIN
DOES NOT PASS TESTING ON THE FIRST TRIAL, THE ADDITIONAL WATER THAT IS
NECESSARY FOR SUBSEQUENT ADDITIONAL DISINFECTION, FLUSHING AND/OR TESTING
SHALL BE MEASURED BY THE WATERLOO WATER WORKS AND PAID TO THE WATERLOO
WATER WORKS AT ITS NORMAL RATE. THE FLOW RATES AT WHICH WATER IS
FURNISHED SHALL BE CONTROLLED BY THE WATERLOO WATER WORKS. THE
CONTRACTOR SHALL FURNISH SATISFACTORY BACKFLOW PREVENTION DEVICES, HOSES
AND ALL OTHER MATERIALS, EQUIPMENT AND LABOR NECESSARY TO COMPLETE SAID
FILLING, FLUSHING AND TESTING AT NO ADDITIONAL COST TO THE OWNER.
CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES BY POTHOLING WITH NO OPEN
EXCAVATIONS AND SHALL AVOID ALL EXISTING UTILITIES, SEWER AND WATER
SERVICES AND SHALL COMPLETE THIS ITEM IN A MANNER THAT DOES NOT DISTURB
SAID ITEMS.
ITEM INCLUDES RESTORING THE BORE HOLES AT THE BORE ENTRY AND EXIT LOCATIONS
SUCH THAT OPEN HOLES ARE NOT LEFT AHEAD OF AND BEHIND THE WATER MAIN TIE-IN
LOCATIONS. HDD PIPE SHALL BE REMOVED TO A MINIMUM OF 4' VERTICAL DEPTH BELOW
EXISTING GRADE AT THE BORE EXIT AND ENTRY POINTS AND THE REMAINING
UNDERGROUND HDD PIPE FROM SAID REMOVAL DEPTH TO THE WATER MAIN TIE-IN
LOCATIONS SHALL BE FILLED WITH CELLULAR CONCRETE. ITEM INCLUDES BACKFILLING ALL
OPEN EXCAVATIONS WITH SUITABLE MATERIALS TO A MINIMUM OF 95% OF THE MATERIALS
OPTIMUM DENSITY AT -2 TO +4% OF ITS OPTIMUM MOISTURE ITEM INCLUDES
RESTORATION OF ALL DISTURBED AREAS TO PRE -CONSTRUCTION CONDITIONS AFTER
TIE-INS ARE COMPLETED. FURNISHING, TRANSPORTING AND INSTALLA11ON OF A 6"
(MINIMUM) THICKNESS OF TOPSOIL AT ALL DISTURBED AREAS THAT ARE NOT ROCKED OR
PAVED IS INCIDENTAL TO THIS ITEM. SAID TOPSOIL MATERIAL SHALL BE PRE -APPROVED
BY THE OWMER'S REPRESENTATIVE PRIOR TO ITS USE ON THIS PROJECT.
THE CONTRACTOR SHALL LOCATE AND MARK THE DRILL -OUT BORE PATH CENTERLINE
LOCATION WITH TILE FLAGS IMMEDIATELY AFTER OR DURING THE BORE -OUT. SAID FLAGS
SHALL BE SET AT A MAXIMUM SPACING OF 25' AND SHALL BE MARKED WITH THE DEPTH
OF THE DRILL PIPE.
411. CONNECTION OF NEW 8" DIA. PVC WATER MAIN TO NEW 8" PVC WATER MAIN
412. CONNECTION OF NEW 8" DIA. PVC WATER MAIN TO EXISTING 8" PVC WATER MAIN
413. CONNECTION OF NEW 8" DIA. PVC WATER MAIN TO NEW 12" PVC WATER MAIN
414. CONNECTION OF NEW 12" DIA. PVC WATER MAIN TO NEW 16" PVC WATER MAIN
415. CONNECTION OF NEW 12" DIA. PVC WATER MAIN TO EXISTING 12" C.I.P./D.I.P. WATER
MAIN
BID PRICE SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, EXCAVATION,
COMPACTION, CLEANING, SHOCK DISINFECTION, HOLDING SPOOLS, RESTRAINED
COUPLINGS, MECHANICAL THRUST RESTRAINTS, POURED P.C. CONCRETE THRUST
RESTRAINTS AND OTHER ITEMS AND WORK, AND APPURTENANT ITEMS NEEDED FOR
CONNECTING THE NEW WATER MAIN TO OTHER NEW WATER MAIN AND TO THE
EXISTING CAST IRON AND DUCTILE IRON PIPE WATER MAINS THAT IS NOT PAID FOR
SEPARATELY UNDER OTHER BID ITEMS. "LAYING DOWN" DIRECTIONALLY DRILLED PIPE
AT BORE ENTRIES AND EXITS TO CONNECT TO NEW AND EXISTING WATER MAINS IS
INCLUDED IN THESE ITEMS AND WILL NOT BE PAID FOR AS SEPARATE WORK.
416. WATER MAIN 8" DIA.. C900 DR18 PVC, BY TRENCHED EXCAVATION
417. WATER MAIN 8" DIA.. D.I.P.. BY TRENCHED EXCAVATION
418. WATER MAIN 12" DIA., C900 DR18 PVC, BY TRENCHED EXCAVATION
419. WATER MAIN 16" DIA., C900 DR18 PVC. BY TRENCHED EXCAVATION
BID PRICE SHALL INCLUDE ALL MATERIALS AND EQUIPMENT NECESSARY TO INSTALL
NEW C-900/RJ PVC DR 18 AND CL 52 DUCTILE IRON PIPE (D.I.P.) WATER MAIN OF
THE VARIOUS SIZES NOTED AS SHOWN ON THESE PLANS BY CONVENTIONAL, OPEN
TRENCH CONSTRUCTION METHODS. PVC PIPE SHALL BE CERTA-LOK BY OR APPROVED
EQUAL WITH RESTRAINED JOINTS. D.I.P. SHALL HAVE NITRILE GASKETS. ITEMS INCLUDE
TWO COPPERHEAD COPPER CLAD STEEL OR APPROVED EQUAL TRACING WIRES.
PVC PIPE SHALL INCLUDE CLASS 1 BEDDING FROM 4" BELOW THE PIPE TO 12" ABOVE
THE PIPE.
D.I.P. SHALL BE WRAPPED IN APPROVED POLYETHELENEE SHEETING.
ALL OPEN TRENCHES SHALL BE BACKFILLED AND COMPACTED WITH UITABLE TRENCH
EXCAVTION MATERIALS IN 9" MAXIMUM LOOSE THICKNESS LIFTS TO A MINIMUM OF 95%
OF THE BACFILL'S MAXIMUM DENSITY AT -2 TO = 3% OF OTS OPTIMUM MOISTURE.
ITEM INCLUDES BACTERIOLOGICAL, PRESSURE, AND LEAKAGE TESTING AND ALL OTHER
ITEMS NECESSARY TO COMPLETE THIS CONSTRUCTION AND TO PROVIDE A PROPERLY
OPERATING WATER MAIN. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS,
EQUIPMENT AND LABOR NECESSARY FOR TESTING THE WATER MAIN. THIS SHALL
INCLUDE RESTRAINED JOINTS ON PIPE AND FITTINGS AT DEADENDS, PLUGS, PIPE AND
CORP STOPS OF SUFFICIENT SIZE FOR FLUSHING AFTER TESTING. ALL TESTS SHALL BE
CONSIDERED INCIDENTAL TO WATER MAIN CONSTRUCTION.
ITEM INCLUDES SHOCK DISINFECTING THE EXISTING HYDRANTS AND PIPING TO BE
RE -LOCATED WITH CONCENTRATED SOLUTIONS AS PER AWWA C651, SEC.4.7,
INCLUDING SEC. 4.7.4 AND SEC 4.7.5.
Base Bid Estimated Project Quantities
EARTHWORK, EROSION CONTROL AND MISCELLANEOUS
ITEM NO.
DESCRIPTION
UNITS
EST. QTY.
ASBUILT QTY
001.
MOBILIZATION
LUMP SUM
1
002.
SEED, FERTIUZE, AND MULCH (IDOT URBAN MIX) BY HYDROSEEDING
ACRES
1
003.
9" DIA., STRAW FILLED WATTLES
LF.
2,175
004.
INLET PROTECTION, SUDAS 9040
EACH
24
005.
TRAFFIC CONTROL
LUMP SUM
LUMP SUM
006.
MAINTENANCE BOND, 2-YEAR
LUMP SUM
LUMP SUM
WATER CONSTRUCTION
ITEM NO.
DESCRIPTION
UNITS
EST. QTY.
401.
HDD #1 WATER MAIN, C900 DR18 PVC, B-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
402.
HDD #2 WATER MAIN, C900 DR18 PVC, B-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
403.
HDD #3 WATER MAIN, C900 DR18 PVC, B-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
404.
HDD #4 WATER MAIN, C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
405
HDD #.5 WATER MAIN, C900 DR18 PVC, 8-INCH CARRIER PIPE IN 12-INCH DR18 C900
PVC CASING PIPE
LUMP SUM
LUMP SUM
406.
HDD #6 WATER MAIN, C900 DR18 PVC, 8-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
407
HDD #7 WATER MAIN, C900 DR18 PVC, 12-INCH CARRIER PIPE IN 16-INCH DR18 C900
PVC CASING PIPE
LUMP SUM
LUMP SUM
408.
HDD #8 WATER MAIN, C900 DR18 PVC, 12-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
409.
HDD #9 WATER MAIN, C900 DR18 PVC, 12-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
410.
HDD #10 WATER MAIN, C900 DR18 PVC, 16-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
411.
CONNECTION OF NEW 8" DIA. PVC WATER MAIN TO NEW 8" PVC WATER MAIN
EACH
5
412.
CONNECTION OF NEW B" DIA. PVC WATER MAIN TO EXISTING 8" PVC WATER MAIN
EACH
5
413.
CONNECTION OF NEW 8" DIA. PVC WATER MAIN TO NEW 12" PVC WATER MAIN
EACH
3
414•
CONNECTION OF NEW 12' DIA PVC WATER MAIN TO NEW 16" PVC WATER MAIN
EACH
1
415.
CONNECTION OF NEW 12' DIA. PVC WATER MAIN TO EXISTING 12- C.I.P/D.I.P WATER MAIN
EACH
1
416.
WATER MAIN 8" DIA., C900 DR18 PVC, BY OPEN TRENCH CONSTRUCTION
LF.
347
417•
WATER MAIN 8" DIA., D.I.P. MATH NITRILE GASKETS
LF.
367
418.
WATER MAIN 12" DIA., C900 DR18 PVC, BY OPEN TRENCH CONSTRUCTION
LF.
651
419.
WATER MAIN 16" DIA., C900 DR18 PVC, BY OPEN TRENCH CONSTRUCTION
LF.
120
420.
TEE, 8" DIA. X 8" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
5
421•
TEE, 12" DIA. X 8" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
2
422.
TEE, 16" DIA. X 12" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
2
BEND, 90', 8" DIA., DUCTILE IRON, COMPLETE WITH THRUST RESTRAINT
EACH
1
BEND, 45. 12- DIA., DUCTILE IRON, COMPLETE WITH THRUST RESTRAINT
EACH
2
r
BEND, 11.25', 12" DIA., DUCTILE IRON, COMPLETE WITH THRUST RESTRAINT
EACH
2
CROSS, 8" DIA.,X 8" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
1
CROSS, 12" DIA.,X 8" DIA., D.L.P. COMPLETE WITH THRUST RESTRAINT
EACH
1
428.
END CAP, 16" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
2
429.
REDUCER, B" DIA. X 6" DIA., D.I.P. COMPLETE WITH THRUST RESTRAINT
EACH
1
430.
INSTALL NEW FIRE HYDRANT ASSEMBLY, M.J., 6.5' BURY, COMPLETE
EACH
14
431.
REMOVE AND SALVAGE EXISTING FIRE HYDRANT ASSEMBLY, COMPLETE
EACH
11
432,
GATE VALVE, 8' DIA., M.J., WITH VALVE BOX AND MECHANICAL THRUST RESTRAINT A
EACH
14
433.
GATE VALVE, 12" DIA., M.J., WITH VALVE BOX AND MECHANICAL THRUST RESTRAINT
EACH
6
434.
GATE VALVE, 16" DIA., M.J., WITH VALVE BOX AND MECHANICAL THRUST RESTRAINT
EACH
3
435.
WATER SERVICE CONNECTION, NEW, 1" DIA., COMPLETE
EACH
50
436.
WATER SERVICE CONNECTION TO EXISTING WATER SERVICE UNE, 1" DIA., COMPLETE
EACH
34
437.
WATER SERVICE, 1" DIA. BY OPEN -CUT EXCAVATION
LF.
439
438.
WATER SERVICE, 1" DIA. BY DIRECTIONAL DRILLING
LF.
811
439.
FILL EXISTING 6" DIA. WATER MAIN WITH CELLULAR CONCRETE
LF.
3,642
440.
FILL EXISTING le DIA. WATER MAIN WITH CELLULAR CONCRETE
LF.
1,998
441.
1 OMIT
-
-
442.
UNK SEALS BETWEEN 8' PVC CARRIER PIPE AND 12" PVC CASING PIPE, WATER TIGHT, COMPLETE
EACH
6
443.
LINK SEALS BETWEEN 12" PVC CARRIER PIPE AND 16" PVC CASING PIPE, WATER TIGHT, COMPLETE
EACH
4
444.
HYDRANT BAGS, FURNISH, INSTALL AND MAINTAIN
EACH
32
445.
HDD #11 WATER MAIN, C900 DR18 PVC, 12-INCH DIRECTIONALLY DRILLED
LUMP SUM
LUMP SUM
PAVING CONSTRUCTION
ITEM NO.
DESCRIPTION
UNITS
EST. QTY.
501.
REMOVE/REPLACE EXISTING HMA STREET PAVEMENT INCLUDING CURB AND GUTTER
S.Y.
380
502.
REMOVE/REPLACE EXISTING PCC DRIVEWAY PAVEMENT
S.Y.
105
503.
REMOVE/REPLACE EXISTING PCC SIDEWALK, 4" THICK
S.Y.
430
504.
ADA INSERTS
EACH
5
�44
00
C
O
� Z
M C
(O C p 0
N I:
m
2 3::-0
0 cd
� ccao 03
C i
)
o =Cd
O
7 C o 0
L Co
tQ
C C .E
■+
U23w