HomeMy WebLinkAboutKWIK STAR #723 ,,•00 Waterloo Fire Rescue 064 Inspection Report 425 E.3rd Street Kwik Star#723-707 Broadway ST,BLDG 707 Broadway St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06/08/2026 Annual Inspection(1Yr) 17580 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 044 ® 9 ® 24 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/0112026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06/08/2026 @ 14:19 •$80 annual inspection fee BRAD BALDWIN-06108/2026 @ 14:19 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06108/2026 @ 14:20 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-06/08/2026 @ 14:20 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alicia(2025)District Manager Date: BRAD BALDWIN 06/08/2026 CHECKLISTS GENERATED ON 6/8/26, 2:45 PM 1 OF 6 Additional Codes Static Code Description Fail 603.9.1-Listed and labeled. Only listed and labeled portable,electric space heaters shall Location:Manager's office be used. Comments:Provide documentation of proper listing and labeling of commercially approved heater or remove from building. Emergency Equipment St4t,:s Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Above Lottery computer at register counter illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate during test. General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container to dispose of oily rags. of such containers shall be removed and disposed of daily. Fire Service Features Status Code Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Address numbers address identification.The address identification shall be Comments:Address numbers shall be in contrast of building and legible and placed in a position that is visible from the street easily legible from the road.Currently numbers blend in and are or road fronting the property.Address identification difficult to see. characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. GENERATED ON 6/8/26, 2:45 PM 2 OF 6 y- Electrical Safety Status Code Description Fail 603.4-Working space and clearancesclearance. (1.) A working space of not Working space around electrical Location:Back stock area-Electric panels equipment shall be provided in accordance with Section Comments:Relocate shelving to avoid obstructing electric panels. 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Maintain 36"clearance from panels at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment,Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:i. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). tor— It tr)iftt_ t C' V,,,i: ,t,__7- _ , d`; P k u s 3 OF 6 GENERATED ON 6/8/26, 2:45 PM Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Panel at end of register counter equipment shall be provided in accordance with Section Comments:Remove signage on panel cover to avoid obstructing 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or clear sight of panel. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). -.: rcwcarucaow 10 I w m II a_. ea 44 w Ofre Pc GENERATED ON 6/8/26, 2:45 PM 4 OF 6 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Above food warming station for permanent wiring and shall be listed and labeled in Comments:Cord shall not extend drop through accordance with UL 817.Extension cords and flexible 5 ceiling in concealed cordsshall not be affixed to structures,extended through space.Make necessary repairs. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. F 0001 N F 4i n � rung Commercial Cooking Hood Suppression System Status Code Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust system cleaning 19 days past due as of 6/8/26. Sections 606.3.3.1 through 606.3.3.3. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected.Tagged by"Fire Protection Services" June 2026 Portable Fire Extingusihers Status Code Description Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Near back exit door shall be installed on the hangers or brackets supplied. Comments:3 spare extinguishers sitting on floor shall be removed Hangers or brackets shall be securely anchored to the from building. mounting surface in accordance with the manufacturer's installation instructions. GENERATED ON 6/8/26, 2:45 PM 5 OF 6 PO Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/8/26, 2:45 PM 6 OF 6 OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,� Y�� 06/10/2026 07/15/2026 2026-00000532 $80.00 i4f. la O • • u u u • > T —T 0 a�S 7tt17‘. Customer#: 3323 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KWIK STAR#723 715 Mulberry St 1626 OAK ST WATERLOO, IA 50703 LA CROSSE, WI 54602 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-707 BROADWAY ST-06/08/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3323 06/10/2026 07/15/2026 2026-00000532 $80.00 Less Prepayment $0.00 Total Due —► $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.