Loading...
HomeMy WebLinkAboutPRIME MART 7 Waterloo Fire Rescue `" y Inspection Report 425 E.3rd Street Prime Mart 7-1309 Lafayette ST,BLDG 1309 Lafayette St,Waterloo IA 50703 INSPECTION DETAILS t��(�y inspection Date Inspection Type g3p 1 iJ Inspection Number 06/0112026 Annual Inspection(1Yr) REINSPECTION � ` '� U� 16759-R2 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 0 0 3 0 8 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 06/25/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-05/07/2026 @ 14:01 $80 Annual inspection fee BRAD BALDWIN-05107/2026 @ 14:01 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-05107/2026 @ 14:01 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-05107/2026©14:01 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-05107/2026 @ 14:01 $100 re-inspection fee due to lack of any progress on 517126.Complete corrections to avoid possible fees at following inspections BRAD BALDWIN-06/04/2026 @ 15:38 $150 re-inspection fee for failure to complete corrections by scheduled re-inspection date of 611/26.Complete corrections to avoid fees at following inspections. SIGNATURES Contact signature Inspector signature No et Report completeded post post inspection GENERATED ON 6/4/26, 3:40 PM I OF Usman Chatha 2026 Date: BRAD BALDWIN 0610412026 CHECKLISTS GENERATED ON 6/4/26, 3:40 PM 2 OF 7 Reinspection Status Coda Description Fail 102.4-Application of building code. OThe design and construction of new structures shall comply Location:Electric permit with the International Building Code,and any alterations, Comments:Contractor(B&C Electric of Iowa)shall obtain additions,changes in use or changes in structures required inspection of work completed.Permit obtained for"12 outlets"in by this code,which are within the scope of the International December 2025. Building Code,shall be made in accordance therewith. Additional comments:No inspection on record yet Fail 603.1.1-Equipment and fixtureswiring. OElectrical equipment and fixtures All electrical equipment, Location:LED lighting(front exterior windows&above coolers) wiring,devices and appliances shall be tested;and listed by Comments:Provide documentation of listing of lights.Lighting shall an approved agency and labeled;and installed,used and be properly listed and comply with listing. maintained in accordance with NFPA 70 and all instructions included as part of such listing. Additional comments:Lighting noted in multiple locations throughout store.All lighting shall be used per its approved listing. Improper usage shall be elimanted. Fail 603.2-Abatement of unsafe conditions and electrical 0 hazards. Location:Near Lotto machine/register counter Identified electrical hazards shall be abated.Identified Comments:Conduit drop shall be properly supported,currently not hazardous electrical conditions in permanent wiring shall be anchored or supported to anything.Also,outlet cover is loose and brought to the attention of the responsible code official. shall be properly installed to avoid exposing wires in box. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. ii :ii; d/O° �—'-- '`,`' - il i: - t:, 1. _ - $ A PI i GENERATED ON 6/4/26, 3:40 PM 3 OF 7 Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:North wall above walk-in fridge Identified electrical hazards shall be abated.Identified Comments:Altered cord(cut and improperly spliced)shall be hazardous electrical conditions in permanent wiring shall be unplugged and removed from building.Also,remove cube style brought to the attention of the responsible code official. multi-plug adapter,would be approved to replace with power strip Electrical wiring,devices,appliances and other equipment with manual reset properly mounted to wall. that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. s i j P f i Fail 603.2.2-Unapproved conditionsOpen electrical terminations. ,x` Open junction boxes and open-wiring splices shall be Location:Near front exit-behind Coke fridge prohibited.Approved covers shall be provided for all switch Comments:Replace broken outlet cover and electrical outlet boxes. i 1 ;_ o 4 b' j 0. GENERATED ON 6/4/26, 3:40 PM 4 OF 7 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Front of building near ice machine prohibited.Approved covers shall be provided for all switch Comments:Exterior rated cover shall be installed and repairs made and electrical outlet boxes. to avoid exposed wiring to exterior elements. j "e Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Above Monster bev fridge at front wall of building. for permanent wiring and shall be listed and labeled in Comments:Remove black cord extending above drop ceiling. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. 3s T / . ' All GENERATED ON 6/4/26, 3:40 PM Fail 603.9.1-Listed and labeled. Only listed and labeled portable,electric space heaters shall Location:Liquor storage be used. Comments:Provide documentation of proper listing and labeling of commercially approved heater or remove from building. Additional comments:heater located in electric panel room during 611/26 inspection GENERATED ON 6/4/26, 3:40 PM 6 OF 7 El, Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $150.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/4/26, 3:40 PM 7 OF 7 of W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 06/10/2026 07/15/2026 2026-00000545 $150.00 u !� o • •I '.I 1 min, • T.r T 0 Customer#: 23198 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PRIME MART 7 715 Mulberry St 1309 LAFAYETTE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-1309 LAFAYETTE ST-06/01/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 2 $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23198 06/10/2026 07/15/2026 2026-00000545 $150.00 Less Prepayment $0.00 Total Due -* $150.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.