HomeMy WebLinkAboutELK'S CLUB Waterloo Fire Rescue Inspection Report t� 425 E.3rd Street Elk's Club-407 E Park AVE,BLDG 407 E Park Ave,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type ��� � � Inspection Number 06/02/2026 Annual Inspection(1Yr) r 17426 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION e 55 0 15 ( 10 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/01/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06/08/2026 @ 07:03 $100 annual inspection fee BRAD BALDWIN-06108/2026 @ 07:03 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06/08/2026 @ 07:04 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-06108/2026 @ 07:04 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Sherri Simon 2026 Date: BRAD BALDWIN 06/08/2026 CHECKLISTS GENERATED ON 6/8/26, 8:17 AM 1 OF 6 Emergency Equipment `:a"s Code Description Fail 1203.2,15-Means of egress illumination. OEmergency power shall be provided for means of egress Location:Billiards room illumination in accordance with Sections 1008.3 and 1104,5.1. Comments:Repair or replace emergency egress light that failed test. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Hallway near Red Stag Room illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Egress(can light)near elevator 2 shall be repaired or replaced.Light failed test during inspection Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Ballroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of all egress lighting tested and repaired if non-functional.Document shall be signed and dated and mailed to inspector Fire Service Features Code Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Park Ave side of building address identification.The address identification shall be Comments:Provide address identification numbers on building legible and placed in a position that is visible from the street easily visible from the road in approved location or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Additional Codes _tss Code Description Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:"Down"kitchen code or the International Building Code shall be installed, Comments:Remove microwave plugged to power strip.Appliances used and maintained in accordance with NFPA 70 and including motors or heating elements shall plug directly to Sections 603.2 through 603.10. permanent wall outlet. 2 OF 6 GENERATED ON 6/8/26, 8:17 AM Electrical Safety Status Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:"Up"kitchen prohibited.Approved covers shall be provided for all switch Comments:Replace broken outlet cover behind condiment fridge and electrical outlet boxes. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Boiler room-above stairs prohibited.Approved covers shall be provided for all switch Comments:Provide knockout plug in opening in box to avoid shock and electrical outlet boxes. hazard s M1y i Fail 603.4-Working space and clearancesclearance. Ox A working space of not Working space around electrical Location:Basement custodial closet equipment shall be provided in accordance with Section Comments:Remove storage blocking access to electric panels, 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or maintain clear access and 36"clearance from panels at all time less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.5.3-Installation. Ox Relocatable power tap cords shall not extend through walls, Location:"Up"kitchen ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip below security camera TV to to environmental or physical damage. avoid hanging by wires. GENERATED ON 6/8/26, 8:17 AM 3 OF 6 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Park Ave lounge for permanent wiring and shall be listed and labeled in Comments:Remove brown extension to security camera,will accordance with UL 817.Extension cords and flexible approve to replace with power strip with manual reset properly cordsshall not be affixed to structures,extended through mounted for low wattage electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Brass lounge for permanent wiring and shall be listed and labeled in Comments:Remove extension cord to"fake fireplace" accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System S:a Code Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen exhaust hood appurtenances shall be cleaned at intervals as required by Comments:Provide annual cleaning and contractor report including Sections 606.3.3.1 through 606.3.3.3. any deficiencies to Compliance Engine.Currently due for cleaning on 6112126.Cleaning is scheduled for 6/11126 Fire Resistant Construction Maintenance Status Code Description Fail 704.1-Maintaining protection. 0 Where required when the building was originally constructed, Location:Brass lounge materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 6/8/26, 8:17 AM 4 OF 6 • Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Ox Portable fire extinguishers shall be selected,installed and Location:Billiards room maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,currently past Exceptions:1.The distance of travel to reach an extinguisher due for service. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. OPortable fire extinguishers shall be selected,installed and Location:Boiler room maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,currently past Exceptions:1.The distance of travel to reach an extinguisher due for service. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 6/8/26, 8:17 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/8/26, 8:17 AM 6 OF 6 O F W4 TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE A �0 06/10/2026 07/15/2026 2026-00000535 $100.00 • ' 1 111 11 1 • T-^ ! O �S 7V11N Customer#: 9492 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ELK'S CLUB 715 Mulberry St 407 E PARK AV WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-407 E. PARK AVE-06/02/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9492 06/10/2026 07/15/2026 2026-00000535 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.