HomeMy WebLinkAboutROBERTS REAL ESTATE ab)/ I Ell55a4e,lie
Waterloo Fire Rescue a 3 t/g as
Inspection Report ,/I� �T� �-0��y 425 E.3rd Street
r�BLDG 1007 Beech St-1007 Beech ST,Waterloo IA 50703-3327 a V kXt J A�J T '
INSPECTION DETAILS 046155
Inspection Date Inspection Type Inspection Number
0511812026 2015 IPMC Rental Inspection (REINSPECTION) 4 ( ) ' 20353-R1
Lead Inspector Shift Station Unit
MIKE HEERKES NIA NIA NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
D O 0 2 0 7
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
MIKE HEERKES 0 612 212 02 6
mike.heerkes@waterloo-ia.org,3192914319
GENERAL NOTES
MIKE HEERKES-0210412026 @ 11:47
All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections.
MIKE HEERKES-0210412026 @ 11:47
Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unitls.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
MIKE HEERKES-0210412026 @ 11:47
Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten
years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection `
Roberts Real Estate Date: MIKE HEERKES 0 512 012 0 2 6
CHECKLISTS
GENERATED ON 5/20/2E, 10:40 AN 1 OF 4
Additional Codes
Status Code Description
Fail 2015 IPMC 304.15 - Doors
CDExterior doors, door assemblies, operator systems if Location: Front entrance
provided, and hardware shall be maintained in good Comments: Front door has hole through exterior side being patched
condition. Locks at all entrances to dwelling units and with duct tape. If door and door frame replacement if needed, would
sleeping units shall tightly secure the door. Locks on means require permit and inspection.
of egress doors shall be in accordance with Section 702.3.
GENERATED ON 5/20/26, 10:40 AM 2 OF 4
Reinspection
Stares Code Description
Fail 2015 IPMC 305.4-Stairs and walking surfaces
Every stair,ramp,landing,balcony,porch,deck or other Location:Basement
walking surface shall be maintained in sound condition and Comments:Stair treads incorrectly repaired
good repair,
Fail 2015 IPMC 307.1-General-Handrails&Guards
Every exterior and interior flight of stairs having more than Location:Basement stairway
four risers shall have a handrail on one side of the stair and Comments:Guard missing on side of stairs
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches Additional comments:New guards for stairs does not meet current
(762 mm)above the floor or grade below shall have guards. building code for spacing.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mtn)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
Fail 2015 IPMC 603.1-Mechanical appliances
Mechanical appliances,fireplaces,solid fuel-burning Location:Furnace
appliances,cooking appliances and water heating appliances Comments:Furnace not working properly as fan does not turn off.
shall be properly installed and maintained in a safe working Have repair person correct.
condition,and shall be capable of performing the intended
function.
Ii Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Basement
than two separate and remote receptacle outlets.Every Comments:Receptacle above dryer has faceplate loose and hanging.
laundry area shall contain not less than one grounding-type Receptacles in storage area missing faceplate
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location
OCarbon monoxide alarms in dwelling units shall be installed Comments:No detector was present at time of inspection
outside of each separate sleeping area in the immediate
vicinity of the bedrooms.Where a fuel-burning appliance is
located within bedroom or its attached bathroom,a carbon
monoxide alarm shall be installed within the bedroom.
Fail 603.2-Abatement of unsafe conditions and electrical
0 hazards. Location:Basement
Identified electrical hazards shall be abated.Identified Comments:Service panel missing cover.
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 5/20/26, 10:40 AM 3 OF 4
O Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $50.00
Invoice Number Check Number Transaction Number
N►A N►A NIA
GENERATED ON 5/2e/26, le:4e AN 4 OF 4
W A 1. INVOICE DATE DUE DATE INVOICE# TOTAL DUE
O „
"rQ 06/01/2026 07/06/2026 2026-00000108 $50.00
• 'II III 111 1 I. •
T "T 0
64S l tl 17‘
Customer#: 24955 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
ROBERTS REAL ESTATE, LLC 715 Mulberry St
123 VEGAS COURT WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION - 1007 BEECH ST-05/18/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24955 06/01/2026 07/06/2026 2026-00000108 $50.00
Less Prepayment $0.00
Total Due -* $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.