HomeMy WebLinkAbout520 LAPORTE ROAD - EL MERCADITO r„Ep,o Waterloo Fire Rescue
*. , Inspection Report 425 E.3rd Street
El Mercadito-520 La Porte RD,BLDG 520 La Porte Rd,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
05101/2026 Annual Inspection(1Yr) 16769
Lead Inspector Station Unit
BRAD BALDWIN NIA NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 35 C 7 ® 36
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
05/26/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-05/0412026 @ 07:12
•$80 annual inspection fee
BRAD BALDWIN-05104/2026 @ 07:12
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-05/04/2026 @ 07:12
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-05/04/2026 @ 07:12
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature �p
Report completed post inspection
Elida ledasma Date: _ BRAD BALDWIN 05/04/2026
CHECKLISTS
GENERATED ON 5/4/26, 3:19 PM 1. OF
Means of Egress
Saws Code Description
Fail 1010.1.3-Door opening force Forces to unlatch and open
doors. Location:Back(west)exit door
The force for pushing or pulling open interior swinging Comments:Repair or replace door to open with less than 15lbs of
egress doors,other than fire doors,shall not exceed 5 force.Hard to open during inspection.
pounds(22 N).These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position.For other swinging doors,
as well as sliding and folding doors,the door latch shall
release when subjected to a 15-pound(67 N)force.The door
shall be set in motion when subjected to a 30-pound(133 N)
force.The door shall swing to a full-open position when
subjected to a 15-pound(67 N)force.The forces to unlatch
doors shall comply with the following:1.Where door
hardware operates by push or pull,the operational force to
unlatch the door shall not exceed 15 pounds(66.7 N).2.Where
door hardware operates by rotation,the operational force to
unlatch the door shall not exceed 28 inch-pounds(315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated,other than doors required to be fire rated,the force
for pushing or pulling open the door shall not exceed 5
pounds(22 N).2.For other swinging doors,sliding doors or
folding doors,and doors required to be fire rated,the door
shall require not more than a 30-pound(133 N)force to be set
in motion and shall move to a full-open position when
subjected to not more than a 15-pound(67 N)force.
GENERATED ON 5/4/26, 3:19 PM 2 OF 7
Additional Codes
Status Code Description
Fail 1010.2.1-Unlatching.
OThe unlatching of any door or leaf for Location:Back(west)exit door
egress shall require not require more than one operation Comments:Unlatching and unlocking door shall take one motion
motion in a single linear or rotational direction to release all only,remove all hardware that exceeds more than one motion.Both
latching and all locking devices.Exceptions:1.Places of deadbolts were noted in locked position during open business hours,
detention or restraint.2.Where manually operated bolt locks door must remain unlocked.
are permitted by Section 1010.2.5.3.Doors with automatic
flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors
from individual dwelling units and sleeping units of Group R
occupancies as permitted by Section 1010.2.4,Item 4 5.
x;
MEEERS
t>rI s >
GENERATED ON 5/4/26, 3:19 PM 3 OF 7
Fail 1010.2.4-Locks and latches.
Locks and latches shall be permitted to prevent operation of Location:Front exit doors(2)
doors where any of the following exist:1.Places of detention Comments:Permanent approved signage shall be installed to doors
or restraint.2.In Group I-1,Condition 2 and Group 1-2 (2)stating,"THIS DOOR SHALL REMAIN UNLOCKED DURING
occupancies where the clinical needs of persons receiving BUSINESS HOURS"
care require containment or where persons receiving care
pose a security threat,provided that all clinical staff can
readily unlock doors at all times,and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space.
GENERATED ON 5/4/26, 3:19 PM 4 OF 7
Fail 509.2-Equipment access.
OApproved access shall be provided and maintained for all fire Location:Electric panel near back exit door
protection system equipment to permit immediate safe Comments:Remove screws in panel door and storage below panel.
operation and maintenance of such equipment.Storage,trash Maintain 36 inches of clearance from panel at all times
and other materials or objects shall not be placed or kept in
such a manner that would prevent such equipment from
being readily accessible.
Fail 605.1.4-Access.
Ox The installation of fuel-fired equipment shall be provided with Location:Mechanical room
access to equipment for cleaning hot surfaces;removing Comments:Remove storage to provide ready access to furnace
burners;replacing motors,controls,air filters,chimney and
vent connectors,draft regulators and other working parts;
and for adjusting,cleaning and lubricating parts.
� \iL
1
\ 1
t5, `
- 1
GENERATED ON 5/4/26, 3:19 PM 5 OF 7
Electrical Safety
S[::,s Code Description
Fail 603.6-Extension cords.
Extension cords and flexible cordsshall not be a substitute Location:West exterior-Above Air Conditioner
for permanent wiring and shall be listed and labeled in Comments:Remove extension cord.
accordance with UL 817,Extension cords and flexible
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
OExtension cords and flexible cordsshall not be a substitute Location:Walk-in fridge
for permanent wiring and shall be listed and labeled in Comments:Flexible wiring shall not extend through concealed area,
accordance with UL 817.Extension cords and flexible remove orange cord running through cooler wall.
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
•
•
tip
GENERATED ON 5/4/26, 3:19 PM 6 OF ,
t'® Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
N/A $80.00
Invoice Number Check Number Transaction Number
N/A NIA NIA
GENERATED ON 5/4/26, 3:19 PM 7 OF 7
f W 4 F INVOICE DATE DUE DATE INVOICE# TOTAL DUE
O
0 06/01/2026 07/06/2026 2026-00000493 $80.00
. ' 1 1/ 1 III ,• .
•
Customer#: 9934 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
EL MERCADITO 715 Mulberry St
520 LA PORTE RD WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-520 LAPORTE RD-05/01/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# " CHARGES
9934 06/01/2026 07/06/2026 2026-00000493 $80.00
Less Prepayment $0.00
Total Due —> $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.