Loading...
HomeMy WebLinkAbout2313 LOGAN AVENUE - GREENLEAF VAPE & TOBACCO-LOGAN AVE Waterloo Fire Rescue n Inspection Report 425 E.3rd Street Greenleaf Vape&Tobacco-2313 Logan AVE,BLDG 2313 Logan Ave,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type ago(0-7- Inspection Number 05115/2026 Annual Inspection(1Yr) (REINSPECTIONJ Jv/50,QO 21242-R2 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors WA SUMMARY OF INSPECTION 0 ® 12 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0611212026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0411712026 @ 13:30 $100 re-inspection due to lack of progress on 4117/26,complete corrections to avoid more fees at following inspections BRAD BALDWIN-04117/2026 @ 13:30 •$80 annual inspection fee BRAD BALDWIN-04/17/2026 @ 13:30 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN-04/1712026 @ 13:30 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-04/17/2026 @ 13:30 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 am.-4:00 p.m.�••"'Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0411712026 @ 13:30 •Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date.Failure to request time or change of date will result in failed inspection. BRAD BALDWIN-05115/2026 @ 15:23 $150 re-inspection fee,failure to complete corrections as of 5115/26.Complete corrections to avoid possible fees at following inspections.Phone call with Mo on 5/15 to discuss remaining corrections. SIGNATURES Contact signature Inspector signature No signature GENERATED ON 5/15/26,3:26 PM 1 or 9 f ■ Report completed post inspection MO (2026) Date: CHECKLISTS GENERATED ON 5/15/26, 3:24 PM 2 OF 9 Reinspection Status Code Description Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Cigar room with the International Building Code,and any alterations, Comments:Building and electrical permits and inspections shall be additions,changes in use or changes in structures required obtained for cigar room built without permits. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. 2`� .j..A t. Al tl gy�, '� 'a l,C V. Aikj ' kF s. aj t e �N sNA i "iri Fail 102.4-Application of building code. OThe design and construction of new structures shall comply Location:Water heater with the International Building Code,and any alterations, Comments:Licensed plumbing contractor shall obtain permit and additions,changes in use or changes in structures required inspection of water heater installed without permit. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 1203.2.6-Exit signs. OEmergency power shall be provided for exit signs as required Location:Front exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and lights that failed to the required load for a duration of not less than 90 minutes. illuminate during test. Fail 603.1.1-Equipment and fixtureswiring. OElectrical equipment and fixtures All electrical equipment, Location:Window LED lighting wiring,devices and appliances shall be tested;and listed by Comments:Provide documentation of proper listing and use of an approved agency and labeled;and installed,used and listing of lighting. maintained in accordance with NFPA 70 and all instructions included as part of such listing. Fail 603.2-Abatement of unsafe conditions and electrical Ohazards. Location:Display cases near front wall Identified electrical hazards shall be abated.Identified Comments:Provide further information to inspector of nature of hazardous electrical conditions in permanent wiring shall be white cords extending from under display cases.If extension cords, brought to the attention of the responsible code official. remove. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 5/15/26, 3:24 PM 3 OF 9 Fail 603.5.3-Installation. 0 Relocatable power tap cords shall not extend through walls, Location:Front window above fridge ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid hanging by wires, to environmental or physical damage. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front wall for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to power strip.Power accordance with UL 817.Extension cords and flexible strip shall be properly mounted to wall to avoid hanging by wires and cordsshall not be affixed to structures,extended through plugged directly to outlet. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • ! t!!jr ;, Fa , GENERATED ON 5/15/26, 3:24 PM 4 OF g Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front window for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to power strip accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. f, , , .. ..,„ , . . ,:,.... _ iiii fli ........ _ _ ..,, iiii 1 GENERATED ON 5/15/26, 3:24 PM 5 OF 9 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front wall behind display cases for permanent wiring and shall be listed and labeled in Comments:Remove white extension cord taped to floor.Cords accordance with UL 817.Extension cords and flexible running across walkway shall be protected by listed floor cord cordsshall not be affixed to structures,extended through protector. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. a.. eR / '','..:, \ IP, 4 ;;:1 }`. t f tit.-:-.- GENERATED ON 5/15/26, 3:24 PM 6 OF 9 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Behind counter below register counter for permanent wiring and shall be listed and labeled in Comments:Provide further information regarding use of white cord accordance with UL 817.Extension cords and flexible extending from below cabinet plugged to power strip. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. - 3 -Nsr r A 4 o • it GENERATED ON 5/15/26, 3:24 PM 7 OF 9 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Behind register,cigarette shelving for permanent wiring and shall be listed and labeled in Comments:Remove white cord extending through above ceiling. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • • teA 031 r}r � m Americas • g 1111 L®w as 41z ��Bc7S1C 1 i111; Fail 906.5-Conspicuous location. Portable fire extinguishers shall be located in conspicuous Location:Below register counter locations where they will have ready access and be Comments:Fire extinguisher shall be relocated to a conspicuous immediately available for use.These locations shall be along location.Currently covered by bags and hidden. normal paths of travel,unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. GENERATED ON 5/15/26, 3:24 PM 8 OF F '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 5/15/26, 3:24 PM 9 OF 9 F W q r INVOICE DATE DUE DATE INVOICE# TOTAL DUE 06/01/2026 07/06/2026 2026-00000495 $150.00 �.,,- 4... !A • • T- O 4S lV17N3 Customer#: 24067 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GREENLEAF TOBACCO AND E-CIGS 715 Mulberry St 1503 E SAN MARNAN DR SUITE C WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2313 LOGAN AVE-05/15/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 2 $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24067 06/01/2026 07/06/2026 2026-00000495 $150.00 Less Prepayment $0.00 Total Due -+ $150.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.