HomeMy WebLinkAbout127 JEFFERSON STREET - HAB PETROLEUM Waterloo Fire Rescue
Inspection Report 425 E.3rd Street
HAB Petroleum-127 Jefferson ST,BLDG 127 Jefferson St,Waterloo IA 50702
INSPECTION DETAILS 2 )1 '
Inspection Date Inspection Type of•L/`/ 11i Inspection Number
05/05/2026 Annual Inspection(1Yr) 17180
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
29 G 13 ® 36
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
05/28/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-05106/2026 @ 07:23
•$80 annual inspection fee
BRAD BALDWIN-05/06/2026 @ 07:23
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-05106/2026 @ 07:23
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-0510612026 @ 07:24
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and S200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Mohammad Bhatti Date: BRAD BALDWIN 05106/2026
CHECKLISTS
GENERATED ON 5/6/26, 11:41 AM OF
Means of Egress
Siam. Code Description
Fail 1032.2-Reliability.
Required exit accesses,exits and exit discharges shall be Location:Exit facing 1st St.
continuously maintained free from obstructions or Comments:Remove all obstructions to clear path of egress to exit.
impediments to full instant use in the case of fire or other Maintain clear path to exit at all times.
emergency where the building area served by the means of
egress is occupied.An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
i _ :', t. 1 ,_ -' ;-
fv �, ._111110k
r S. a -VW-- _
I Fe.
{ ...
t 6 !' i3 .,
1
•
.k, "'` `
'Ca t I
111
2 OF 8
GENERATED ON 5/6/26, 11:41 AM
Additional Codes
Status Code Description
Fail 102.4-Application of building code.
The design and construction of new structures shall comply Location:2025 Remodel Permit
with the International Building Code,and any alterations,
Comments:Final inspection shall be obtained for remodel permit.
additions,changes in use or changes in structures required
by this code,which are within the scope of the International Framing inspection has passed but no final inspection on record as
Building Code,shall be made in accordance therewith. of 516126.
Fail 5303.5.3-Securing compressed gas containers,cylinders
and tanks. Location:Near old back exit
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
Fail 603.1-General.
,x 1 Electrical equipment,wiring and systems required by this Location:Near front exit
code or the International Building Code shall be installed,
Comments:Remove microwave plugged to power strip.All
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10. appliances with motors or heat producing elements shall plug
directly to permanent wall outlet.
GENERATED ON 5/6/26, 11:41 AM
3 OF 8
Emergency Equipment
star:- Code Description
Fail 1203.2.15-Means of egress illumination.
Emergency power shall be provided for means of egress Location:Men's bathroom
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Emergency egress light removed shall be replaced and in
proper working condition.
111
Fail 1203.2.15-Means of egress illumination.
Emergency power shall be provided for means of egress
Location:Women's bathroom
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate
during test
Fire Service Features
Desu iption
Stir„ Code
Fail 505.1-Address identification.
New and existing buildings shall be provided with approved Location:Front of building facing Jefferson St.
address identification.The address identification shall be Comments:Address numbers are currently not in contrast with the
legible and placed in a position that is visible from the street building and easily visible from the road.Numbers shall be relocated
or road fronting the property.Address identification to a contrasting location or colors altered to be visible from the road.
characters shall contrast with their background.Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out.Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke
width of 112 inch(12.7 mm).Where required by the fire code
official,address identification shall be provided in additional
approved locations to facilitate emergency response.Where
access is by means of a private road and the building cannot
be viewed from the public way,a monument,pole or other
sign or means shall be used to identify the structure.Address
identification shall be maintained.
4 OF 8
GENERATED ON 5/6/26, 11:41 AM
Electrical Safety
Status Code Description
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Location:Ceiling-above hallway towards bathrooms
prohibited.Approved covers shall be provided for all switch Comments:Provide missing cover to box.
and electrical outlet boxes.
•
•
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
Open junction boxes and open-wiring splices shall be Comments:Provide missing switch cover
prohibited.Approved covers shall be provided for all switch
and electrical outlet boxes.
11.11
w_
5 OF 6
GENERATED ON 5/6/26, 11:41 AM
Fail 603.5-Relocatable power taps and current taps.Multiplug
adapters. Location:Ceiling-hallway toward bathrooms
Multiplug adapters,such as cube adapters,unfused plug Comments:Remove green multi plug adapter,may replace with
strips or any other device not complying with NFPA 70 shall properly mounted power strip with manual reset for low wattage
be prohibited.The construction and use of current taps and electrical equipment only
relocatable taps shall be in accordance with NFPA 70 and this
code.
Fail 603.5.3-Installation.
Relocatable power tap cords shall not extend through walls, Location:Near front exit&"Live Bait"fridge
ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly mounted to avoid hanging
to environmental or physical damage. by wires
Fire Resistant Construction Maintenance
Status Code Description
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Entire space
materials and systems used to protect joints and voids in the Comments:Install ceiling tiles in all missing locations throughout
following locations shall be maintained.The materials and building.
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
GENERATED ON 5/6/26, 11:41 AM 6 OF 8
Portable Fire Extingusihers
Status Code Description
Fail 906.2-General requirements.
Ox Portable fire extinguishers shall be selected,installed and Comments:Provide annual service to all fire extinguishers.Currently
maintained in accordance with this section and NFPA 10. due May 2026
Exceptions:1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device,provided that all of the
following conditions are met:2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal.2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10.3.In Group 1-3,portable fire
extinguishers shall be permitted to be located at staff
locations.
GENERATED ON 5/6/26, 11:41 AN 7 OF 8
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $80.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 5/6/26, 11:41 AM 8 OF 8
F W q . INVOICE DATE DUE DATE INVOICE# TOTAL DUE
o F,p
,� e 0 06/01/2026 07/06/2026 2026-00000496 $80.00
)vs,"o
4S ivtl‘
Customer#: 23091 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
HAB PETROLEUM 715 Mulberry St
127 JEFFERSON WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-127 JEFFERSON-05/05/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE a INVOICE# CHARGES
23091 06/01/2026 07/06/2026 2026-00000496 $80.00
Less Prepayment $0.00
Total Due—* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.