HomeMy WebLinkAbout610 E. 4TH STREET - RENAISSANCE PARK APARTMENTS Waterloo Fire Rescue 0) Inspection Report 425 E.3rd Street Renaissance Park Apartments-610 E 4th ST,BLDG 610 E 4th St,Waterloo IA 50703 INSPECTION DETAILS (1095 Inspection Date Inspection Type Inspection Number 05126/2026 Residential Common Areas Inspection V'/}%V� — 17417 Lead Inspector Shift Station Unit JEREMIAH VANDYKE NIA N/A NIA Other Inspectors N/A SUMMARY OF INSPECTION 019 06 ® 7 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE 06/25/2026 jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE-05/26/2026 @ 13:18 Fire due October 2026 4111(, rtt • i 1 y QoAspo 7. M 2025/2020❑ I 0 JEREMIAH VANDYKE-05/2612026 @ 14:59 Boilers were last inspected September 16th by Youngs plumbing and heating. JEREMIAH VANDYKE-05/2612026 @ 15:10 PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE-05/2612026 @ 15:11 GENERATED ON 5/26/26, 3:12 PM 1 OF 5 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then 6150,and S200 for all subsequent re-inspections.- JEREMIAH VANDYKE-0512612026 @ 15:11 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615 JEREMIAH VANDYKE-05/2612026 @ 15:11 Inspection Fee=S100.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Lynne zellhoefer Date: JEREMIAH VANDYKE 0512612026 CHECKLISTS 2 OF 5 GENERATED ON 5/26/26, 3:12 PM Residential Common Areas Inspection Status Code Description Fail 1032.2-Reliability. ORequired exit accesses,exits and exit discharges shall be Location:South stairway. continuously maintained free from obstructions or Comments:Salt at top needs to be moved and shopping carts impediments to full instant use in the case of fire or other removed on 1st floor. emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 1032.4-Exit signs. OExit signs shall be installed and maintained in accordance Location:Near room#46. with the building code that was in effect at the time of Comments:Exit light tested and failed. construction and the applicable provisions in Section 1104. Decorations,furnishings,equipment or adjacent signage that impairs the visibility of exit signs,creates confusion or prevents identification of the exit shall not be allowed. Fail 1104.5-Illumination emergency power. 0 Where means of egress illumination is provided,the power Location:Near room#12. supply for means of egress illumination shall normally be Comments:Egress light tested and failed. provided by the premises'electrical supply.In the event of power supply failure,illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress:1.Group A having 50 or more occupants. Exception:Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories. 4.Group F having more than 100 occupants.Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code.5.Group I.6.Group M. Exception:Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines. 7.Group R-1.Exception:Where each sleeping unit has direct access to the outside of the building at grade.8.Group R-2. Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Fail 610.1.2-Maintenance. Ox The lint trap,mechanical and heating components,and the Location:Record of cleaning needed. exhaust duct system of a clothes dryer shall be maintained in Comments:Record of cleaning needed. accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. GENERATED ON 5/26/26, 3:12 PM 3 OF 5 Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:South stairway floor 2 door. materials and systems used to protect joints and voids in the Comments:Fire rated door needs to close and latch properly. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonf ire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:5th floor trash chute door. materials and systems used to protect joints and voids in the Comments:Need to install new latch and have chute door close and following locations shall be maintained.The materials and latch correctly. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer'5 installation instructions. aoF s GENERATED ON 5/26/26, 3:12 PM Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 5/26/26, 3:12 PN 5 OF 5 of WA TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE �0 06/01/2026 07/06/2026 2026-00000508 $100.00 U o o 4•' 7t/ 3 Customer#: 11098 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable RENAISSANCE PARK APT 715 Mulberry St 610 E 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-610 E. 4TH ST-05/26/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10 00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11098 06/01/2026 07/06/2026 2026-00000508 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.