Loading...
HomeMy WebLinkAbout200 E. ARLINGTON STREET - ROOSEVELT SENIOR HOUSING Waterloo Fire Rescue Inspection Report 425 E.3rd Street iittigA Roosevelt Senior Housing-200 E Arlington ST,BLDG 200 E Arlington St,Waterloo IA 50703 INSPECTION DETAILS ObISeUelf 41.151 Inspection Date Inspection Type 7�� Inspection Number C 05/29/2026 Residential Common Areas Inspection Lem 17440 Lead Inspector Shift Station Unit JEREMIAH VANDYKE NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 022 03 ® 6 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE 06128/2026 jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE-0512912026 @ 11:47 Fire extinguishers serviced Proshield 2026 Feb. JEREMIAH VANDYKE-05/29/2026 @ 11:48 No clothes dryers in building. JEREMIAH VANDYKE-05/29/2026 @ 12:05 PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE-05/29/2026 @ 12:05 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-05/2912026 @ 12:05 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615 JEREMIAH VANDYKE-05/29/2026 @ 12:06 Inspection Fee=$100.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 5/29/26, 12:14 PM 1 OF 4 Gene Evens-District Manager Date: )0 /0 CHECKLISTS JEREMIAH VANDYKE 0512912026 2OF 4 GENERATED ON 5/29/26, 12:14 PM Residential Common Areas Inspection Status Code Description Fail 2015 IFC-Fire alarm testing and maintenance Is the fire alarm system powered,operational and displaying Location:Fire alarm needs serviced.Compliance engine shows an normal operation(no troubles,supervisory,or alarms)? deficiency. Comments:Deficiency Found:Answer:Fire Alarm is not being monitored.Contact fire alarm contractor as soon as possible. Fail 901.6-Inspection,testing and maintenance. Fire detection and alarm systems,emergency alarm systems, Location:5 Deficiencies on compliance engine for sprinkler system. gas detection systems,fire-extinguishing systems, Contact sprinkler contractor to fix issues and update compliance mechanical smoke exhaust systems and smoke and heat engine. vents protection and life safety systems shall be maintained Comments:Deficiencies Reviewed(Check All:)Deficiency Found: in an operative condition at all times,and shall be replaced or Answer:Flow switch body cover is broken.Deficiency Found: repaired where defective.Nonrequired fire protection and life Answer:2"piping on city side of the backflow is corroded and safety systems and equipment shall be inspected,tested and leaking.Deficiency Found:Answer:2nd floor laundry room sprinkler maintained or removed in accordance with Section 901.8. head needs extended down further.Deficiency Found:Answer: Several painted sprinkler heads need replaced.Deficiency Found: Answer:Sprinkler heads more than 20 years old need sample tested andlor replaced. Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Elevator room. following locations:1.In new and existing Group A,B,E,F,H, Comments:Fire extinguisher needs serviced in elevator room.Send I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group picture. R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 5/29/26, 12:14 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 5/29/26, 12:14 PM 4 OF 4 O F W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE *" � 06/01/2026 07/06/2026 2026-00000513 $100.00 u.,iair�... f O > O 4S 7tf17\� Customer#: 23804 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ROOSEVELT HOUSING 715 Mulberry St 755 SELBY AVE WATERLOO, IA 50703 SAINT PAUL, MN 55104 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-200 E. ARLINGTON ST- FOR BILLING INQUIRY: (319)291-4323 05/29/2026 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23804 06/01/2026 07/06/2026 2026-00000513 $100.00 Less Prepayment $0.00 Total Due —4 $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.