HomeMy WebLinkAbout200 E. ARLINGTON STREET - ROOSEVELT SENIOR HOUSING Waterloo Fire Rescue
Inspection Report
425 E.3rd Street
iittigA Roosevelt Senior Housing-200 E Arlington ST,BLDG 200 E Arlington St,Waterloo
IA 50703
INSPECTION DETAILS ObISeUelf 41.151
Inspection Date Inspection Type 7�� Inspection Number
C
05/29/2026 Residential Common Areas Inspection Lem 17440
Lead Inspector Shift Station Unit
JEREMIAH VANDYKE NIA NIA NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
022 03 ® 6
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to:
Reinspection Date
JEREMIAH VANDYKE
06128/2026
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE-0512912026 @ 11:47
Fire extinguishers serviced Proshield 2026 Feb.
JEREMIAH VANDYKE-05/29/2026 @ 11:48
No clothes dryers in building.
JEREMIAH VANDYKE-05/29/2026 @ 12:05
PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must
be completed by a licensed electrical contractor with permits and inspections.
JEREMIAH VANDYKE-05/29/2026 @ 12:05
Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are
Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed
the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees
may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-05/2912026 @ 12:05
Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615
JEREMIAH VANDYKE-05/29/2026 @ 12:06
Inspection Fee=$100.00(To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 5/29/26, 12:14 PM
1 OF 4
Gene Evens-District Manager Date: )0 /0
CHECKLISTS
JEREMIAH VANDYKE 0512912026
2OF 4
GENERATED ON 5/29/26, 12:14 PM
Residential Common Areas Inspection
Status Code Description
Fail 2015 IFC-Fire alarm testing and maintenance
Is the fire alarm system powered,operational and displaying Location:Fire alarm needs serviced.Compliance engine shows an
normal operation(no troubles,supervisory,or alarms)? deficiency.
Comments:Deficiency Found:Answer:Fire Alarm is not being
monitored.Contact fire alarm contractor as soon as possible.
Fail 901.6-Inspection,testing and maintenance.
Fire detection and alarm systems,emergency alarm systems, Location:5 Deficiencies on compliance engine for sprinkler system.
gas detection systems,fire-extinguishing systems, Contact sprinkler contractor to fix issues and update compliance
mechanical smoke exhaust systems and smoke and heat engine.
vents protection and life safety systems shall be maintained Comments:Deficiencies Reviewed(Check All:)Deficiency Found:
in an operative condition at all times,and shall be replaced or Answer:Flow switch body cover is broken.Deficiency Found:
repaired where defective.Nonrequired fire protection and life Answer:2"piping on city side of the backflow is corroded and
safety systems and equipment shall be inspected,tested and leaking.Deficiency Found:Answer:2nd floor laundry room sprinkler
maintained or removed in accordance with Section 901.8. head needs extended down further.Deficiency Found:Answer:
Several painted sprinkler heads need replaced.Deficiency Found:
Answer:Sprinkler heads more than 20 years old need sample tested
andlor replaced.
Fail 906.1-Where required.
Portable fire extinguishers shall be installed in all of the Location:Elevator room.
following locations:1.In new and existing Group A,B,E,F,H,
Comments:Fire extinguisher needs serviced in elevator room.Send
I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group
picture.
R-2 occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C.2.In Group E
occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3.In storage areas of Group
S occupancies where forklift,powered industrial truck or
powered cart operators are the primary occupants,fixed
extinguishers,as specified in NFPA 10,shall not be required
where in accordance with all of the following:3.1.Use of
vehicle-mounted extinguishers shall be approved by the fire
code official.3.2.Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use.3.3.Not less than
two spare extinguishers of equal or greater rating shall be
available on-site to replace a discharged extinguisher.3.4.
Vehicle operators shall be trained in the proper operation,use
and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30
feet(9144 mm)distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1;1-2,Condition 1;and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance
with Section 3316.1.5.Where required by the sections
indicated in Table 906.1.6.Special-hazard areas,including but
not limited to laboratories,computer rooms and generator
rooms,where required by the fire code official.Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
GENERATED ON 5/29/26, 12:14 PM 3 OF 4
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $100.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 5/29/26, 12:14 PM 4 OF 4
O F W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE
*" � 06/01/2026 07/06/2026 2026-00000513 $100.00
u.,iair�... f O
> O
4S 7tf17\�
Customer#: 23804 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
ROOSEVELT HOUSING 715 Mulberry St
755 SELBY AVE WATERLOO, IA 50703
SAINT PAUL, MN 55104
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-200 E. ARLINGTON ST- FOR BILLING INQUIRY: (319)291-4323
05/29/2026
Description Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23804 06/01/2026 07/06/2026 2026-00000513 $100.00
Less Prepayment $0.00
Total Due —4 $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.