Loading...
HomeMy WebLinkAbout441 E TOWER PARK DRIVE - CHILITO'S Of W p Tk• INVOICE DATE DUE DATE INVOICE# TOTAL DUE 06/18/2026 07/23/2026 2026-00000569 $80.00 o u„aar.1... d O • T _T, 0 _S ?VON Customer#: 21369 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CHILITO'S 715 Mulberry St 441 E TOWER PARK DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 441 E. TOWER ST- 06/09/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21369 06/18/2026 07/23/2026 2026-00000569 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Qom."+ Chilitos Mexican Bar-441 E Tower Park DR,BLDG 441 E Tower Park Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type )) Inspection Number 06/09/2026 Annual Inspection(1Yr) C ,co 17827 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 034 ® 16 ® 30 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/02/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06110/2026 @ 06:58 •$80 annual inspection fee BRAD BALDWIN-06110/2026 @ 06:58 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06110/2026 @ 06:58 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-06/10/2026 @ 06:58 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature2I? Report completedeelpost stinspection Aurora Torres Date: BRAD BALDWIN 06110/2026 CHECKLISTS GENERATED ON 6/10/26, 7:43 AM 1 OF 10 Means of Egress Status Code Description Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Back exit continuously maintained free from obstructions or Comments:Remove obstructions to clear path of egress to exit door impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment s,,-t 5 Code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Front exit(exterior door) in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and lights that failed to the required load for a duration of not less than 90 minutes. illuminate during test General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container for disposal of oily rags.See of such containers shall be removed and disposed of daily. attached Fag l&I oie • • _ GENERATED ON 6/10/26, 7:43 AM 2 OF 10 Electrical Safety Scat s Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Women's bathroom Identified electrical hazards shall be abated.Identified Comments:Floor fan cord pinched in doorway shall be removed hazardous electrical conditions in permanent wiring shall be immediately brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:North exterior of building Identified electrical hazards shall be abated.Identified Comments:Licensed electrician shall make necessary repairs to hazardous electrical conditions in permanent wiring shall be damaged conduit to avoid exposed wiring.Obtain invoice of work brought to the attention of the responsible code official. completed to provide to inspector. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. �. s� "! e s 't tie , s h r-,..x , 4-, s 7.--yp e\,,, , - :. -----_, —.1s-:-..,41 vli t- itl'y Y f ''' Vi Wl ''k r ' Rz lift 3 OF 10 GENERATED ON 6/10/26, 7:43 AM Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Northwest dining area for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to Dos Equis lighted accordance with UL 817.Extension cords and flexible sign.Flexible wiring also not allowed to extend through drop ceiling cordsshall not be affixed to structures,extended through in to concealed spaces. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. 1 , WO 1 s Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Outdoor patio for permanent wiring and shall be listed and labeled in Comments:Per City Electrical Inspector:Remove extension cord accordance with UL 817.Extension cords and flexible plugged to patio"tree"with lights.Licensed electrician shall be cordsshall not be affixed to structures,extended through obtained to inspect proper wiring connections and wiring to the tree walls,ceilings or floors,or under doors or floor coverings, and make any necessary repairs,report or repair invoice shall be nor shall such cords be subject to environmental damage or kept and shown to inspector physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Outdoor patio bar for permanent wiring and shall be listed and labeled in Comments:Remove brown extension cord in bar accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 6/10/26, 7:43 AM 4 OF 10 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar for permanent wiring and shall be listed and labeled in Comments:Remove white multi-plug extension cord plugged to pink accordance with UL 817.Extension cords and flexible power strip. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 6/10/26, 7:43 AM 5 OF 10 Additional Codes sa[_is Crde Description Fail 606.2-Where required. A Type I hood shall be installed at or above all commercial Location:Kitchen-Mini fryer cooking appliances and domestic cooking appliances used Comments:Cooking equipment producing grease laden vapors shall for commercial purposes that produce grease vapors. be installed under hood exhaust system.Currently mini fryer is Exceptions:1.Factory-built commercial exhaust hoods that outside of hood coverage.Mini fryer shall also be removed from are listed and labeled in accordance with UL 710,and plugged to an extension cord. installed in accordance with Section 304.1 of the International Mechanical Code,shall not be required to comply with Sections 507.1.5,507.2.3,507.2.5,507.2.8,507.3.1,507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 7108,and installed in accordance with Section 304.1 of the International Mechanical Code,shall not be required to comply with Sections 507.1.5,507.2.3,507.2.5,507.2.8,507.3.1,507.3.3, 507.4 and 507.5 of the International Mechanical Code.Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code.For the purpose of determining the floor area required to be ventilated,each individual appliance shall be considered as occupying not less than 100 square feet(9.3 m2).3.Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96,a hood shall not be required at or above them.4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mglm3 or less of grease when tested at an exhaust flow rate of 500 cfm(0.236 m31s)in accordance with UL 710B. • • if > rA Fail 606.3.1-Ventilation system. The ventilation system in connection with hoods shall be Location:Kitchen-Fryer operated at the required rate of air movement,and grease Comments:Filter not in place shall be installed. filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. GENERATED ON 6/10/26, 7:43 AM 6 OF 10 Fail 606.3.4-Extinguishing system service. 0 Automatic fire-extinguishing systems protecting commercial Location:Kitchen-All exhaust hoods cooking systems shall be serviced as required in Section Comments:Several suppression head covers noted off,covers shall 904.13.5. be maintained coveringsuppression heads at all times. 4 v , 9 Ilk €cj - t; ' t \ ‘ ' .''' ' , illik\,, \\ , ' Ili : a ,._,......- GENERATED ON 6/10/26, 7:43 AM 7 OF 10 Commercial Cooking Hood Suppression System S'auls ;-.cL;_ Description Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen exhaust hood suppression appurtenances shall be inspected at intervals specified in Comments:Provide suppression system inspection report with any Table 606.3.3.1 or as approved by the fire code official. deficiencies corrected.Contractor must upload report to Compliance Inspections shall be completed by qualified individuals. Engine.Currently 147 days past due for uploaded report Fail 606.3.3.2-Grease accumulation. If during the inspection it is found that hoods,grease-removal Location:Kitchen-Main hood devices,fans,ducts or other appurtenances have an Comments:Accumulation of grease noted on hood exhaust accumulation of grease,such components shall be cleaned in suppression lines today,remove all excess grease. accordance with A NSIIIKECA C10. iii , ..4 v ‘,,, : rif II ;) 4 N. , 1 . , . , , T b 41111, L e g, m,` rs- 34 4 t GENERATED ON 6/10/26, 7:43 AN 8 OF 10 Fire Resistant Construction Maintenance Status Code Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Kitchen-Above microwave and dishwashing station materials and systems used to protect joints and voids in the Comments:Provide missing ceiling tiles. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. OPortable fire extinguishers shall be selected,installed and Location:Kitchen-Class K extinguisher maintained in accordance with this section and NFPA 10. Comments:Annual service due in July 2026 Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 6/10/26, 7:43 AN 9 OF 10