Loading...
HomeMy WebLinkAbout3301 GREYHOUND DRIVE - LOVES COUNTRY STORE W A r INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4F4+ kk 06/18/2026 07/23/2026 2026-00000571 $80.00 . 1A0 • . „1.1 ,Ir . Customer#: 23121 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LOVES COUNTRY STORE 715 Mulberry St 3301 GREYHOUND DR WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-3301 GREYHOUND DR- FOR BILLING INQUIRY: (319)291-4323 06/09/2026 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23121 06/18/2026 07/23/2026 2026-00000571 $80.00 Less Prepayment $0.00 Total Due —* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street ice+ Loves Country Store-3301 Greyhound DR,BLDG 3301 Greyhound Dr,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06/09/2026 Annual Inspection(3Yr) I 15602 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 39 d 10 ® 26 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07108/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06/10/2026 @ 08:02 •$80 annual inspection fee BRAD BALDWIN-06110/2026 @ 08:02 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06110/2026 @ 08:02 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-06/10/2026 @ 08:02 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completededpost stinspection Andy Wilson Date: BRAD BALDWIN 06/10/2026 CHECKLISTS GENERATED ON 6/10/26, 2:53 PM 1 OF 5 Means of Egress Status Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:Exit door near showers The force for pushing or pulling open interior swinging Comments:Repair or replace exit door that failed to open with less egress doors,other than fire doors,shall not exceed 5 than 15Ibs of force during inspection.Replacement of door requires pounds(22 N).These forces do not apply to the force permit and inspection obtained. required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Deli prep area illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light above shelving that failed to illuminate during test.Also,lower storage below egress light to avoid blocking view of lighting in case of emergency. Fire Sprinkler System Status Code Description Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Customer laundry room obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler heads. distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 6/10/26, 2:53 PM 2 OF 5 Electrical Safety Status Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:SE parking lot-Air station near gas pumps Identified electrical hazards shall be abated.Identified Comments:Licensed electrician shall be obtained to make necessary hazardous electrical conditions in permanent wiring shall be repairs to exterior receptacle.Currently unable to open and access brought to the attention of the responsible code official. outlet and wiring pinched by cover.Obtain invoice of work completed Electrical wiring,devices,appliances and other equipment to provide to inspector. that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. } _ , • mow. m �fr r .. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Front Loves!Wendys sign post prohibited.Approved covers shall be provided for all switch Comments:Provide missing weather rated outlet cover. and electrical outlet boxes. • 40. 04-` n wM t t.. .. ,r • 3 OF 5 GENERATED ON 6/10/26, 2:53 PM Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Ice machine room equipment shall be provided in accordance with Section Comments:Remove obstructions to clear path of access to electric 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or panel.Maintain 36"clearance to panel at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Additional Codes Status Code Description Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Customer and"DAS"clothes dryers exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning dryer vent piping accordance with the manufacturer's operating from the appliances to the exterior including signed and dated. instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Fail 907.8.4-Inspection,testing and maintenance. The building owner shall be responsible to maintain the fire Location:Towel room and life safety systems in an operable condition at all times. Comments:Replace missing smoke detector,bracket on wall without Service personnel shall meet the qualification requirements detector present. of NFPA 72 for inspection,testing and maintenance of such systems.Records of inspection,testing and maintenance shall be maintained. Fire Resistant Construction Maintenance Status Code Description Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Towel room and latch automatically. Comments:Repair or replace fire rated door that failed to self-shut and latch.Replacement of door requires permit and inspection obtained. Fail 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be Location:Rolling fire door separating LoveslWendys inspected and tested annually to confirm proper operation Comments:Provide documentation of annual fire drop door test and full closure.Records of inspections and testing shall be maintained. GENERATED ON 6/10/26, 2:53 PM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 6/10/26, 2:53 PM 5 OF 5