Loading...
HomeMy WebLinkAbout428 FRANKLIN STREET - XO FOOD & LIQUOR OF W q?.� INVOICE DATE DUE DATE INVOICE# TOTAL DUE „, ��a/�0 06/18/2026 07/23/2026 2026-00000577 $80.00 f'n.,liar.••• , O • II Him I lllllllll • T- T O S 7v11‘ Customer#: 24548 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable XO FOOD & LIQUOR 715 Mulberry St 428 FRANKLIN ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 428 FRANKLIN ST- 06/12/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24548 06/18/2026 07/23/2026 2026-00000577 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. • " Waterloo Fire Rescue ,i,s k Inspection Report 425 E.3rd Street 4140 XO Food&Liquor•428 Franklin ST,BLDG 428 Franklin St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0611212026 Annual Inspection(1Yr) .f ,l 5 4 gi 17467 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 42 10 ® 25 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/08/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06/15/2026©07:33 •$80 annual inspection fee BRAD BALDWIN-0611512026 @ 07:33 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(45)-Cell:319-230-1224 BRAD BALDWIN-0611512026 @ 07:33 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0611512026 @ 07:33 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection Fahad Mpa Date: BRAD BALDWIN 0611512026 CHECKLISTS GENERATED ON 6/15/26, 8:19 AM OF 7 General Housekeeping S,e -s Code Description Fail 315.3.1-Ceiling clearance. Storage shall be maintained 2 feet(610 mm)or more below Location:Back storage area the ceiling in nonsprinklered areas of buildings or not less Comments:Remove storage within 24 inches of ceiling(not including than 18 inches(457 mm)below sprinkler head deflectors in storage along walls). sprinklered areas of buildings.Exceptions:1.The 2-foot(610 mm)ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings.2.The 18-inch(457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1,903.3.1.2 or 903.3.1.3. Fire Service Features Ste: Coo Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Front of building address identification.The address identification shall be Comments:Provide address identification numbers on Franklin St legible and placed in a position that is visible from the street side of building(north)in contrast with building easily visible from or road fronting the property.Address identification the road.Currently small numbers above door are very difficult to see characters shall contrast with their background.Address from road. numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Additional Codes 5[ar�is Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Back storage area Compressed gas containers,cylinders and tanks shall be Comments:Secure all compressed gas cylinders with chain to avoid secured to prevent falling caused by contact,vibration or tip over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. GENERATED ON 6/15/26, 8:19 AM 2 OF 7 Electrical Safety Ci Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:East exterior-Behind vacuum system Identified electrical hazards shall be abated.Identified Comments:Licensed electrical contractor shall make necessary hazardous electrical conditions in permanent wiring shall be repairs to damaged wiring/conduit.Obtain invoice of work completed brought to the attention of the responsible code official. by electrician. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 441 • 1 GENERATED ON 6/15/26, 8:19 AM 3 OF 7 Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Back storage behind stand up freezer Identified electrical hazards shall be abated.Identified Comments:Licensed electrical contractor shall make necessary hazardous electrical conditions in permanent wiring shall be repairs to improper wiring to box.Obtain invoice of work completed brought to the attention of the responsible code official. by electrician. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. • Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Electric panel room-Quad outlet box near panel Identified electrical hazards shall be abated.Identified Comments:Left receptacle loose in box shall be repaired by licensed hazardous electrical conditions in permanent wiring shall be electrician. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 6/15/26, 8:19 AM 4 OF 7 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. UOpen junction boxes and open-wiring splices shall be Location:East exterior-Building overhang prohibited.Approved covers shall be provided for all switch Comments:Improper wiring out of box shall be corrected by licensed and electrical outlet boxes. electrician,(wiring unprotected from edges of box).Obtain copy of invoice of work completed by electrician. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Electric panel room prohibited.Approved covers shall be provided for all switch Comments:Provide missing outlet cover next to panel. and electrical outlet boxes. /'' k"—* 411:ik f 1 1 *0 1116,V1 .41110 'i "t. _ ,— '-.,-- xi,, rir e `, j GENERATED ON 6/15/26, 8:19 AM ., uF Commercial Cooking Hood Suppression System Stagy i. Corte Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust system cleaning 68 days past due as of 6/15126. Sections 606.3.3.1 through 606.3.3.3. Provide bi-annual cleaning and report to be uploaded to Compliance Engine with current deficiency corrected"Need to repair or install new hinge kit".AKA tagged last serviced April 2026 Fail 606.3.3.2-Grease accumulation. If during the inspection it is found that hoods,grease-removal Location:Kitchen I Cooking Equipment devices,fans,ducts or other appurtenances have an Comments:Clean all accumulations of grease,hood exhaust filters accumulation of grease,such components shall be cleaned in dripping grease,walls behind cooking equipment noted layer of accordance with ANSIIIKECA C10. grease and inside cooking appliances(see attached photo). otoO SIB ..�nc�., 0001}_ 0--- <t 1 GENERATED ON 6/15/26, 8:19 AM 6 OF 7 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/15/26, 8:19 AM 7 OF 7