COMMERCIAL FIRE INSPECTION - 21 W. JEFFERSON ST- FOR BILLING INQUIRY: (319)291-4323
06/16/2026
Description Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23831 06/18/2026 07/23/2026 2026-00000579 $100.00
Less Prepayment $0.00
Total Due -* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
4.),, Inspection Report
i 425 E.3rd Street
42410 The Lofts at Grand Crossing-21W Jefferson ST,BLDG 21 W Jefferson St-STE
Floors 2-4,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
06/1612026 Residential Common Areas Inspection 673CSI t X , 17155
Lead Inspector Shift Station Unit
JEREMIAH VANDYKE N/A NIA N/A
Other Inspectors
NIA
SUMMARY OF INSPECTION
020 04 (S) 7
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
JEREMIAH VANDYKE 0711612026
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE-06/1612026 @ 12:23
All life safety systems are compliance per our Compliance engine website.
JEREMIAH VANDYKE-06/1612026 @ 12:24
Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are
Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed
the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees
may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-06/16/2026 @ 12:24
Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615
JEREMIAH VANDYKE-06/1612026 @ 12:25
Inspection Fee=$100.00(To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
C
sn
Report completed post inspection
Lamar Sayles-Maintenance Date: JEREMIAH VANDYKE 06/16/2026
CHECKLISTS
GENERATED ON 6/16/26, 12:25 PM 1 OF 4
Residential Common Areas Inspection
Siaius CocL•: Description
Fail 1104.5-Illumination emergency power.
Where means of egress illumination is provided,the power Location:3 egress lights.1.Stairwell B 1st floor and to garage 2
supply for means of egress illumination shall normally be lights failed.2.Stairwell A light going to garage.1 light.
provided by the premises'electrical supply.In the event of Comments:Need to repair or replace egress lights.Send video after
power supply failure,illumination shall be automatically repaired 319-883-1615
provided from an emergency system for the following
occupancies where such occupancies require two or more
means of egress:1.Group A having 50 or more occupants.
Exception:Assembly occupancies used exclusively as a
place of worship and having an occupant load of less than
300.2.Group B buildings three or more stories in height,
buildings with 100 or more occupants above or below a level
of exit discharge serving the occupants or buildings with
1,000 or more total occupants.3.Group E in interior exit
access and exit stairways and ramps,corridors,windowless
areas with student occupancy,shops and laboratories.
4.Group F having more than 100 occupants.Exception:
Buildings used only during daylight hours and that are
provided with windows for natural light in accordance with
the International Building Code.5.Group I.6.Group M.
Exception:Buildings less than 3,000 square feet(279 m2)in
gross sales area on one story only,excluding mezzanines.
7.Group R-1.Exception:Where each sleeping unit has direct
access to the outside of the building at grade.8.Group R-2.
Exception:Where each dwelling unit or sleeping unit has
direct access to the outside of the building at grade.
Fail 610.1.2-Maintenance.
The lint trap,mechanical and heating components,and the Location:Need records of dryer cleaning logs.
exhaust duct system of a clothes dryer shall be maintained in Comments:Send records to my email.
accordance with the manufacturer's operating
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
Fail 703.1-Maintaining protection.
Materials and firestop systems used to protect membrane and Location:Trash chutes on floors 2,3,and 4th.
through penetrations in fire-resistance-rated construction and Comments:Chutes are either not closing or latching.Some may need
construction installed to resist the passage of smoke shall be to be replaced.Send video after repairs or replacement to my cell
maintained.The materials and firestop systems shall be 319-883-1615 of properly closing and latching.
securely attached to or bonded to the construction being
penetrated with no openings visible through or into the cavity
of the construction.Where the system design number is
known,the system shall be inspected to the listing criteria
and manufacturer's installation instructions.
GENERATED ON 6/16/26, 12:25 PM 2 OF 4
Fail 906.1-Where required.
Portable fire extinguishers shall be installed in all of the Location:Extinguisher are due this month.
following locations:1.In new and existing Group A,B,E,F,H, Comments:Send invoice after serviced to my email.
I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group
R-2 occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C.2.In Group E
occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3.In storage areas of Group
S occupancies where forklift,powered industrial truck or
powered cart operators are the primary occupants,fixed
extinguishers,as specified in NFPA 10,shall not be required
where in accordance with all of the following:3.1.Use of
vehicle-mounted extinguishers shall be approved by the fire
code official.3.2.Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use.3.3.Not less than
two spare extinguishers of equal or greater rating shall be
available on-site to replace a discharged extinguisher.3.4.
Vehicle operators shall be trained in the proper operation,use
and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30
feet(9144 mm)distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1;1-2,Condition 1;and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance
with Section 3316.1.5.Where required by the sections
indicated in Table 906.1.6.Special-hazard areas,including but
not limited to laboratories,computer rooms and generator
rooms,where required by the fire code official.Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
GENERATED ON 6/16/26, 12:25 PM 3 OF 4