Loading...
HomeMy WebLinkAbout21 W JEFFERSON STREET - THE LOFTS AT GRAND CROSSING OF W AT4' INVOICE DATE DUE DATE INVOICE# TOTAL DUE A 0� 06/18/2026 07/23/2026 2026-00000579 $100.00 ,rav��� /A O • • ) O 6.4S lvt1N� Customer#: 23831 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable THE LOFTS AT GRAND CROSSING 715 Mulberry St 21 W JEFFERSON ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 21 W. JEFFERSON ST- FOR BILLING INQUIRY: (319)291-4323 06/16/2026 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23831 06/18/2026 07/23/2026 2026-00000579 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 4.),, Inspection Report i 425 E.3rd Street 42410 The Lofts at Grand Crossing-21W Jefferson ST,BLDG 21 W Jefferson St-STE Floors 2-4,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06/1612026 Residential Common Areas Inspection 673CSI t X , 17155 Lead Inspector Shift Station Unit JEREMIAH VANDYKE N/A NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 020 04 (S) 7 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE 0711612026 jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE-06/1612026 @ 12:23 All life safety systems are compliance per our Compliance engine website. JEREMIAH VANDYKE-06/1612026 @ 12:24 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-06/16/2026 @ 12:24 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615 JEREMIAH VANDYKE-06/1612026 @ 12:25 Inspection Fee=$100.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature C sn Report completed post inspection Lamar Sayles-Maintenance Date: JEREMIAH VANDYKE 06/16/2026 CHECKLISTS GENERATED ON 6/16/26, 12:25 PM 1 OF 4 Residential Common Areas Inspection Siaius CocL•: Description Fail 1104.5-Illumination emergency power. Where means of egress illumination is provided,the power Location:3 egress lights.1.Stairwell B 1st floor and to garage 2 supply for means of egress illumination shall normally be lights failed.2.Stairwell A light going to garage.1 light. provided by the premises'electrical supply.In the event of Comments:Need to repair or replace egress lights.Send video after power supply failure,illumination shall be automatically repaired 319-883-1615 provided from an emergency system for the following occupancies where such occupancies require two or more means of egress:1.Group A having 50 or more occupants. Exception:Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories. 4.Group F having more than 100 occupants.Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code.5.Group I.6.Group M. Exception:Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines. 7.Group R-1.Exception:Where each sleeping unit has direct access to the outside of the building at grade.8.Group R-2. Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Need records of dryer cleaning logs. exhaust duct system of a clothes dryer shall be maintained in Comments:Send records to my email. accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Fail 703.1-Maintaining protection. Materials and firestop systems used to protect membrane and Location:Trash chutes on floors 2,3,and 4th. through penetrations in fire-resistance-rated construction and Comments:Chutes are either not closing or latching.Some may need construction installed to resist the passage of smoke shall be to be replaced.Send video after repairs or replacement to my cell maintained.The materials and firestop systems shall be 319-883-1615 of properly closing and latching. securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 6/16/26, 12:25 PM 2 OF 4 Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Extinguisher are due this month. following locations:1.In new and existing Group A,B,E,F,H, Comments:Send invoice after serviced to my email. I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 6/16/26, 12:25 PM 3 OF 4 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/16/26, 12:25 PM 4 OF 4