HomeMy WebLinkAbout45 W JEFFERSON STREET - GRAND CROSSING APARTMENTS OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE
�f�0 06/18/2026 07/23/2026 2026-00000580 $100.00
u aiv41.. / O
.,
•
)6. O 4s 7v10`
Customer#: 23124 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
GRAND CROSSING APARTMENTS 715 Mulberry St
45 W JEFFERSON ST WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 45 W. JEFFERSON ST- FOR BILLING INQUIRY: (319)291-4323
06/16/2026
Description Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23124 06/18/2026 07/23/2026 2026-00000580 $100.00
Less Prepayment $0.00
Total Due — $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
p a Inspection Report 425 E.3rd Street
4440 Grand Crossing-45 W Jefferson ST,BLDG 45 W Jefferson,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
06/16/2026 Residential Common Areas Inspection D3 ,4 45 leo 7 18625
Lead Inspector Shift Station Unit
JEREMIAH VANDYKE N/A NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
19 0 5 ® 7
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org 07/1612026
GENERAL NOTES
JEREMIAH VANDYKE-06/1612026 @ 12:05
BH sprinkler doing monthly checks of Fire pump last recorded 5/15/2026.
JEREMIAH VANDYKE-0611612026 @ 12:13
All life safety systems in place according to our Compliance engine.
JEREMIAH VANDYKE-06/1612026 @ 12:14
Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are
Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed
the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees
may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-06/1612026 @ 12:14
Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615
JEREMIAH VANDYKE-06/1612026 @ 12:14
Inspection Fee=$100.00(To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Lamar Sayles-Maintenance Date: JEREMIAH VANDYKE 06116/2026
GENERATED ON 6/16/26, 12:14 PM 1 OF 5
•
CHECKLISTS
GENERATED ON 6/16/26, 12:14 PM 2 OF 5
Residential Common Areas Inspection
Status Code Description
Fail 1032.2-Reliability.
Required exit accesses,exits and exit discharges shall be Location:4th floor stairway door near room 418.
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other Comments:Door was hard to open need to adjust and send video
emergency where the building area served by the means of after repaired.
egress is occupied,An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Fail 1104.5-Illumination emergency power.
Where means of egress illumination is provided,the power Location:1st floor stairwell A.
supply for means of egress illumination shall normally be Comments:Egress light tested and failed.Send video of working
provided by the premises'electrical supply.In the event of
power supply failure,illumination shall be automatically light after repaired to my cell.319-883-1615
provided from an emergency system for the following
occupancies where such occupancies require two or more
means of egress:1.Group A having 50 or more occupants.
Exception:Assembly occupancies used exclusively as a
place of worship and having an occupant load of less than
300.2.Group B buildings three or more stories in height,
buildings with 100 or more occupants above or below a level
of exit discharge serving the occupants or buildings with
1,000 or more total occupants.3.Group E in interior exit
access and exit stairways and ramps,corridors,windowless
areas with student occupancy,shops and laboratories.
4.Group F having more than 100 occupants.Exception:
Buildings used only during daylight hours and that are
provided with windows for natural light in accordance with
the International Building Code.5.Group I.6.Group M.
Exception:Buildings less than 3,000 square feet(279 m2)in
gross sales area on one story only,excluding mezzanines.
7.Group R-1.Exception:Where each sleeping unit has direct
access to the outside of the building at grade.8.Group R-2.
Exception:Where each dwelling unit or sleeping unit has
direct access to the outside of the building at grade.
Fail 610.1.2-Maintenance.
The lint trap,mechanical and heating components,and the Location:Records of dryer vents cleaning.
exhaust duct system of a clothes dryer shall be maintained in Comments:Email records of dryer vent cleanings.
accordance with the manufacturer's operating
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
Fail 901.6-Inspection,testing and maintenance.
0 Fire detection and alarm systems,emergency alarm systems, Location:Generator service report.
gas detection systems,fire-extinguishing systems, Comments:Please send records of last generator inspection report.
mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained
in an operative condition at all times,and shall be replaced or
repaired where defective.Nonrequired fire protection and life
safety systems and equipment shall be inspected,tested and
maintained or removed in accordance with Section 901.8.
GENERATED ON 6/16/26, 12:14 PM 3 OF 5
Fail 906.1-Where required.
Portable fire extinguishers shall be installed in all of the
Location:Fire extinguishers due this month for annual.
following locations:1.In new and existing Group A,B,E,F,H, Comments:Send invoice to email after serviced.
I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group
R-2 occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C.2.In Group E
occupancies,portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3.In storage areas of Group
S occupancies where forklift,powered industrial truck or
powered cart operators are the primary occupants,fixed
extinguishers,as specified in NFPA 10,shall not be required
where in accordance with all of the following:3.1.Use of
vehicle-mounted extinguishers shall be approved by the fire
code official.3.2.Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use.3.3.Not less than
two spare extinguishers of equal or greater rating shall be
available on-site to replace a discharged extinguisher.3.4.
Vehicle operators shall be trained in the proper operation,use
and inspection of extinguishers.3.5.Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30
feet(9144 mm)distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1;1-2,Condition 1;and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance
with Section 3316.1.5.Where required by the sections
indicated in Table 906.1.6.Special-hazard areas,including but
not limited to laboratories,computer rooms and generator
rooms,where required by the fire code official.Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
4 OF 5
GENERATED ON 6/16/26, 12:14 PM
Po Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $100.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 6/16/26, 12:14 PM 5 OF 5