Loading...
HomeMy WebLinkAbout45 W JEFFERSON STREET - GRAND CROSSING APARTMENTS OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE �f�0 06/18/2026 07/23/2026 2026-00000580 $100.00 u aiv41.. / O ., • )6. O 4s 7v10` Customer#: 23124 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GRAND CROSSING APARTMENTS 715 Mulberry St 45 W JEFFERSON ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 45 W. JEFFERSON ST- FOR BILLING INQUIRY: (319)291-4323 06/16/2026 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23124 06/18/2026 07/23/2026 2026-00000580 $100.00 Less Prepayment $0.00 Total Due — $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue p a Inspection Report 425 E.3rd Street 4440 Grand Crossing-45 W Jefferson ST,BLDG 45 W Jefferson,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06/16/2026 Residential Common Areas Inspection D3 ,4 45 leo 7 18625 Lead Inspector Shift Station Unit JEREMIAH VANDYKE N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 19 0 5 ® 7 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org 07/1612026 GENERAL NOTES JEREMIAH VANDYKE-06/1612026 @ 12:05 BH sprinkler doing monthly checks of Fire pump last recorded 5/15/2026. JEREMIAH VANDYKE-0611612026 @ 12:13 All life safety systems in place according to our Compliance engine. JEREMIAH VANDYKE-06/1612026 @ 12:14 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-06/1612026 @ 12:14 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615 JEREMIAH VANDYKE-06/1612026 @ 12:14 Inspection Fee=$100.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Lamar Sayles-Maintenance Date: JEREMIAH VANDYKE 06116/2026 GENERATED ON 6/16/26, 12:14 PM 1 OF 5 • CHECKLISTS GENERATED ON 6/16/26, 12:14 PM 2 OF 5 Residential Common Areas Inspection Status Code Description Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:4th floor stairway door near room 418. continuously maintained free from obstructions or impediments to full instant use in the case of fire or other Comments:Door was hard to open need to adjust and send video emergency where the building area served by the means of after repaired. egress is occupied,An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Fail 1104.5-Illumination emergency power. Where means of egress illumination is provided,the power Location:1st floor stairwell A. supply for means of egress illumination shall normally be Comments:Egress light tested and failed.Send video of working provided by the premises'electrical supply.In the event of power supply failure,illumination shall be automatically light after repaired to my cell.319-883-1615 provided from an emergency system for the following occupancies where such occupancies require two or more means of egress:1.Group A having 50 or more occupants. Exception:Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories. 4.Group F having more than 100 occupants.Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code.5.Group I.6.Group M. Exception:Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines. 7.Group R-1.Exception:Where each sleeping unit has direct access to the outside of the building at grade.8.Group R-2. Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Records of dryer vents cleaning. exhaust duct system of a clothes dryer shall be maintained in Comments:Email records of dryer vent cleanings. accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Fail 901.6-Inspection,testing and maintenance. 0 Fire detection and alarm systems,emergency alarm systems, Location:Generator service report. gas detection systems,fire-extinguishing systems, Comments:Please send records of last generator inspection report. mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective.Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. GENERATED ON 6/16/26, 12:14 PM 3 OF 5 Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Fire extinguishers due this month for annual. following locations:1.In new and existing Group A,B,E,F,H, Comments:Send invoice to email after serviced. I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. 4 OF 5 GENERATED ON 6/16/26, 12:14 PM Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/16/26, 12:14 PM 5 OF 5