COMMERCIAL FIRE INSPECTION -209 W. 5TH ST- 06/12/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
4749 06/18/2026 07/23/2026 2026-00000581 $100.00
Less Prepayment $0.00
Total Due S100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
ceD Inspection Report 425 E.3rd Street
Russell-Lamson-209 W 5th ST,BLDG 209 W.5th St,Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
06112/2026 Residential Common Areas inspection it 7.4 CO 17234
Lead Inspector Shift Station Unit
JEREMIAH VANDYKE NIA NIA NIA
Other Inspectors
NIA
SUMMARY OF INSPECTION
022 07 ® 5
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
JEREMIAH VANDYKE 0711212026
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE-06112/2026 @ 11:31
Hawkeye fire and safety fire extinguishers Feb.2026.
JEREMIAH VANDYKE-0611212026 @ 11:32
Fire pump last inspected by BH sprinkler and logged 512012026.
JEREMIAH VANDYKE-0611212026 @ 11:32
Clothes dryer logged in house and cleaned 610212026
JEREMIAH VANDYKE-0611212026 @ 15:07
All life safety systems are compliant according to compliance engine website.
JEREMIAH VANDYKE-0611212026 @ 15:11
PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must
be completed by a licensed electrical contractor with permits and inspections.
JEREMIAH VANDYKE-0611212026 @ 15:11
Re-Inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are
Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed
the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to setup an earlier re-inspection....Re inspection fees
may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then 6150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-0611212026 @ 15:11
LL Van Dyke-ieremiah.vandyke@waterloo-ia.org-Work:319.291-4460-Cell:319.883-1615
JEREMIAH VANDYKE-0611212026 @ 15:11
Inspection Fee=$100.00(To be mailed out by City via snail mail.)
SIGNATURES
GENERATED ON 6/12/26, 3:12 PM 1 OF 5
Contact signature Inspector signature
No signature
Report completed post inspection
Kathy Nelson Date: JEREMIAH VANDYKE 06/12/2026
CHECKLISTS
GENERATED ON 6/12/26, 3:12 PM
2 OF 5
Residential Common Areas Inspection
Status Code Description
Fail 1103.9-Carbon monoxide alarmsdetection.
Carbon monoxide alarms detection shall be installed in Location:1st floor south side of building near stairway B
existing dwelling units and sleeping units Group 1-1,I-2,I-0 Comments:Carbon Monoxide tested and failed.Send picture of new
and R occupancies and in classrooms in Group E Carbon Monoxide placed after getting new one.
occupancies where those units include any of the conditions
identified in Sections 915.1.2 through 915.1.6.The carbon
monoxide alarms shall be installed in the locations specified
in Section 915.2 and the installation shall be in accordance
with Section 915.4.Exceptions:1.Carbon monoxide alarms
are permitted to be solely battery operated where the code
that was in effect at the time of construction did not require
carbon monoxide detectors to be provided.2.Carbon
monoxide alarms are permitted to be solely battery operated
in dwelling units that are not served from a commercial power
source.3.A carbon monoxide detection system in accordance
with Section 915.5 shall be an acceptable alternative to
carbon monoxide alarms.
Fail 1104.5-Illumination emergency power.
OWhere means of egress illumination is provided,the power Location:Broken light in stairway near boiler room on 2nd floor.
supply for means of egress illumination shall normally be Comments:Missing bulbs that need to be installed.
provided by the premises'electrical supply.In the event of
power supply failure,illumination shall be automatically
provided from an emergency system for the following
occupancies where such occupancies require two or more
means of egress:1.Group A having 50 or more occupants.
Exception:Assembly occupancies used exclusively as a
place of worship and having an occupant load of less than
300.2.Group B buildings three or more stories in height,
buildings with 100 or more occupants above or below a level
of exit discharge serving the occupants or buildings with
1,000 or more total occupants.3.Group E in interior exit
access and exit stairways and ramps,corridors,windowless
areas with student occupancy,shops and laboratories.
4.Group F having more than 100 occupants.Exception:
Buildings used only during daylight hours and that are
provided with windows for natural light in accordance with
the International Building Code.S.Group I.6.Group M.
Exception:Buildings less than 3,000 square feet(279 m2)in
gross sales area on one story only,excluding mezzanines.
7.Group R-1.Exception:Where each sleeping unit has direct
access to the outside of the building at grade.B.Group R-2.
Exception:Where each dwelling unit or sleeping unit has
direct access to the outside of the building at grade.
Fail 506.2-Key box maintenance.
0 The operator of the building shall immediately notify the fire Location:Any changes in the Knox Box keys or updated keys?
code official and provide the new key where a lock is changed Comments:Any changes in the Knox Box keys or updated keys?
or rekeyed.The key to such lock shall be secured in the key
box.
Fail 610.1.2-Maintenance.
The lint trap,mechanical and heating components,and the Location:Lint build up behind machines that needs to be vaccumed
exhaust duct system of a clothes dryer shall be maintained in and cleaned.
accordance with the manufacturer&13039;s operating Comments:Send pictures after getting area cleaned.
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
ill
GENERATED ON 6/12/26,3:12 PM 3 OF 5
Fail 901.6 - Inspection, testing and maintenance.
OFire detection and alarm systems, emergency alarm systems, Location: Need records of latest generator inspections.
gas detection systems, fire-extinguishing systems, Comments: Need records of latest generator inspections. The one
mechanical smoke exhaust systems and smoke and heat last completed was 512025 by Cedar Valley Electric.
vents protection and life safety systems shall be maintained
in an operative condition at all times, and shall be replaced or
repaired where defective. Nonrequired fire protection and life
safety systems and equipment shall be inspected, tested and
maintained or removed in accordance with Section 901.8 .
Fail 901.6 - Inspection, testing and maintenance.
OFire detection and alarm systems, emergency alarm systems, Location: Boiler inspection report.
gas detection systems, fire-extinguishing systems, Comments: Need last inspection of Boiler inspection.
mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained
in an operative condition at all times, and shall be replaced or
repaired where defective. Nonrequired fire protection and life
safety systems and equipment shall be inspected, tested and
maintained or removed in accordance with Section 901.8 .
Additional Codes
Status Code Description
Fail 913.5.2 - Generator sets.
0 Engine generator sets supplying emergency or standby Location: Generator log was blanked in boiler room.
power to fire pump assemblies shall be periodically tested in Comments: Need to contact Generator contractor to learn how to log
accordance with NFPA 110. Records of testing shall be generator reports. Send records of log after filling out for a month.
maintained.