Loading...
HomeMy WebLinkAbout209 W 5TH STREET - RUSSELL LAMSON BUILDING4749 OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE A , 'Q a 06/18/2026 07/23/2026 2026-00000581 $100.00 o • 'U e I I • a4S ivi7N� Customer#: 4749 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable RUSSELL LAMSON BLDG 715 Mulberry St 209 W 5TH ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -209 W. 5TH ST- 06/12/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4749 06/18/2026 07/23/2026 2026-00000581 $100.00 Less Prepayment $0.00 Total Due S100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue ceD Inspection Report 425 E.3rd Street Russell-Lamson-209 W 5th ST,BLDG 209 W.5th St,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06112/2026 Residential Common Areas inspection it 7.4 CO 17234 Lead Inspector Shift Station Unit JEREMIAH VANDYKE NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 022 07 ® 5 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE 0711212026 jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE-06112/2026 @ 11:31 Hawkeye fire and safety fire extinguishers Feb.2026. JEREMIAH VANDYKE-0611212026 @ 11:32 Fire pump last inspected by BH sprinkler and logged 512012026. JEREMIAH VANDYKE-0611212026 @ 11:32 Clothes dryer logged in house and cleaned 610212026 JEREMIAH VANDYKE-0611212026 @ 15:07 All life safety systems are compliant according to compliance engine website. JEREMIAH VANDYKE-0611212026 @ 15:11 PERMIT INFO:•Any construction,electrical,plumbing,life safety,and HVAC requires proper permit and inspections.•All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE-0611212026 @ 15:11 Re-Inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to setup an earlier re-inspection....Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then 6150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-0611212026 @ 15:11 LL Van Dyke-ieremiah.vandyke@waterloo-ia.org-Work:319.291-4460-Cell:319.883-1615 JEREMIAH VANDYKE-0611212026 @ 15:11 Inspection Fee=$100.00(To be mailed out by City via snail mail.) SIGNATURES GENERATED ON 6/12/26, 3:12 PM 1 OF 5 Contact signature Inspector signature No signature Report completed post inspection Kathy Nelson Date: JEREMIAH VANDYKE 06/12/2026 CHECKLISTS GENERATED ON 6/12/26, 3:12 PM 2 OF 5 Residential Common Areas Inspection Status Code Description Fail 1103.9-Carbon monoxide alarmsdetection. Carbon monoxide alarms detection shall be installed in Location:1st floor south side of building near stairway B existing dwelling units and sleeping units Group 1-1,I-2,I-0 Comments:Carbon Monoxide tested and failed.Send picture of new and R occupancies and in classrooms in Group E Carbon Monoxide placed after getting new one. occupancies where those units include any of the conditions identified in Sections 915.1.2 through 915.1.6.The carbon monoxide alarms shall be installed in the locations specified in Section 915.2 and the installation shall be in accordance with Section 915.4.Exceptions:1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided.2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source.3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. Fail 1104.5-Illumination emergency power. OWhere means of egress illumination is provided,the power Location:Broken light in stairway near boiler room on 2nd floor. supply for means of egress illumination shall normally be Comments:Missing bulbs that need to be installed. provided by the premises'electrical supply.In the event of power supply failure,illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress:1.Group A having 50 or more occupants. Exception:Assembly occupancies used exclusively as a place of worship and having an occupant load of less than 300.2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants.3.Group E in interior exit access and exit stairways and ramps,corridors,windowless areas with student occupancy,shops and laboratories. 4.Group F having more than 100 occupants.Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code.S.Group I.6.Group M. Exception:Buildings less than 3,000 square feet(279 m2)in gross sales area on one story only,excluding mezzanines. 7.Group R-1.Exception:Where each sleeping unit has direct access to the outside of the building at grade.B.Group R-2. Exception:Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. Fail 506.2-Key box maintenance. 0 The operator of the building shall immediately notify the fire Location:Any changes in the Knox Box keys or updated keys? code official and provide the new key where a lock is changed Comments:Any changes in the Knox Box keys or updated keys? or rekeyed.The key to such lock shall be secured in the key box. Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Lint build up behind machines that needs to be vaccumed exhaust duct system of a clothes dryer shall be maintained in and cleaned. accordance with the manufacturer&13039;s operating Comments:Send pictures after getting area cleaned. instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. ill GENERATED ON 6/12/26,3:12 PM 3 OF 5 Fail 901.6 - Inspection, testing and maintenance. OFire detection and alarm systems, emergency alarm systems, Location: Need records of latest generator inspections. gas detection systems, fire-extinguishing systems, Comments: Need records of latest generator inspections. The one mechanical smoke exhaust systems and smoke and heat last completed was 512025 by Cedar Valley Electric. vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . Fail 901.6 - Inspection, testing and maintenance. OFire detection and alarm systems, emergency alarm systems, Location: Boiler inspection report. gas detection systems, fire-extinguishing systems, Comments: Need last inspection of Boiler inspection. mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . Additional Codes Status Code Description Fail 913.5.2 - Generator sets. 0 Engine generator sets supplying emergency or standby Location: Generator log was blanked in boiler room. power to fire pump assemblies shall be periodically tested in Comments: Need to contact Generator contractor to learn how to log accordance with NFPA 110. Records of testing shall be generator reports. Send records of log after filling out for a month. maintained. GENERATED ON 6/12/26, 3:12 PM 4 OF 5 RD Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/12/26, 3:12 PM 5 OF 5