Loading...
HomeMy WebLinkAbout3330 E 4TH STREET - UNION AT NORTH CROSSING - CP CLUBHOUSE OF W q rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE e 06/18/2026 07/23/2026 2026-00000583 $80.00 u . O • • i/ 1 11+1 • *- 0 6,S 7 v''`." Customer#: 24730 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable UNION AT NORTH CROSSING - CP 715 Mulberry St 409 MASSACHUSETTS WATERLOO, IA 50703 DETROIT, MI 48204 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3330 E. 4TH ST CLUBHOUSE - FOR BILLING INQUIRY: (319)291-4323 06/15/20 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24730 06/18/2026 07/23/2026 2026-00000583 $80.00 Less Prepayment $0.00 Total Due -f $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street BLDG Union at North Crossing Club House 3330 E 4th St.•3330 East 4th Street, Waterloo IA 50703 tat)INSPECTION DETAILS Inspection Date Inspection Type inspection Number 06115/2026 Residential Common Areas Inspection 16927 Lead Inspector Shin Station Unit JEREMIAH VANDYKE N/A NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 016 04 ® 12 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org 0 711512 0 2 6 GENERAL NOTES JEREMIAH VANDYKE-06/1512026 @ 15:50 Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to setup an earlier re-inspection."'..Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-0611512026 @ 15:50 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319.883.1615 JEREMIAH VANDYKE-0611512026 @ 15:51 Inspection Fee=$80.00(To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection y 0 \ / Jessica Tordsen-Assistant Property Manager Date: JEREMIAH VANDYKE 0 611 512 0 2 6 CHECKLISTS GENERATED ON 6/15/26,3:52 RN 1 DF 4 Residential Common Areas Inspection Status Code Description Fail 610.1.2 - Maintenance. OThe lint trap, mechanical and heating components, and the Location: Dryer Vent: ensure that the vent is completely cleaned to exhaust duct system of a clothes dryer shall be maintained in the outside of the building - keep a log of maintenance - person/date. accordance with the manufacturer&14039;s operating Comments: Need record of cleaning dryer vents or when getting instructions to prevent the accumulation of lint or debris that scheduled. prevents the exhaust of air and products of combustion, Fail 901.6 - Inspection, testing and maintenance. OFire detection and alarm systems, emergency alarm systems, Location: Fire alarm is past due on compliance Engine. gas detection systems, fire-extinguishing systems, Comments: Contact licensed fire alarm contractor to inspect the fire mechanical smoke exhaust systems and smoke and heat alarm and upload report under Name UNION AT NORTH CROSSING vents protection and life safety systems shall be maintained CLUB HOUSE-OFFICE Address 3330 E 4TH ST WATERLOO, IA 50703- in an operative condition at all times, and shall be replaced or 2002 repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . Fail 901.6 - Inspection, testing and maintenance. OFire detection and alarm systems, emergency alarm systems, Location: Private hydrants are past due. gas detection systems, fire-extinguishing systems, Comments: Name UNION AT NORTH CROSSING CLUB HOUSE- mechanical smoke exhaust systems and smoke and heat OFFICE Contact licensed sprinkler contractor to inspect private vents protection and life safety systems shall be maintained hydrants and upload report to Compliance engine unver the Address in an operative condition at all times, and shall be replaced or 3330E 4TH ST WATERLOO, IA 50703-2002 repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . GENERATED ON 6/15/26, 3:52 PM 2 OF 4 Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:All buildings. following locations:1.In new and existing Group A,B,E,F,H, Comments:All fire extinguishers are past due and needs serviced. I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In Group R-2 occupancies,portable fire extinguishers shall be required Send invoice to email of work completed. only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 6/15/26, 3:52 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/15/26, 3:52 PM 4 OF 4