COMMERCIAL FIRE INSPECTION - 941 E. SAN MARNAN DR.- FOR BILLING INQUIRY: (319)291-4323
06/10/2026
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24976 06/18/2026 07/23/2026 2026-00000592 $80.00
Less Prepayment $0.00
Total Due-p $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
NE Inspection Report /VFW 425 E.3rtl Street
Izumi Sushi Restaurant-941 E San Marnan DR,BLDG 941 E San Marnan Dr,
Waterloo IA 50702
INSPECTION DETAILS 9('4-
Inspection Date Inspection Type C.i/l�/L'1y)) Inspection Number
0611012026 Annual Inspection(1Yr) 11224
Lead Inspector Shift Station Unit
BRAD BALDWIN NIA NIA NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
053 014 012
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN 07/02/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-0611112026 @ 08:22
•$80 annual inspection fee
BRAD BALDWIN-0611112026 @ 08:22
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-06111/2026 @ 08:22
•Provide corrections to avoid progressive re-inspection fees beginning at$100.BeerlLiquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-0 611112 02 6 @ 08:23
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.".**Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-06111/2026 @ 08:42
Corrected during 6110126 inspection-Removed heated water appliance from multi-plug adapter and plugged to wall outlet.
SIGNATURES
Contact signature Inspector signature
No signature post
Report completed post inspection
Restaurant email 2026 Date: BRAD BALDWIN 0611112026
CHECKLISTS
GENERATED ON 6/11/26,9:51 AN
OF 7
Means of Egress
Status Code Description
Fail 1010.1.3- Door opening force Forces to unlatch and open
doors. Location: Exit door near bathrooms
The force for pushing or pulling open interior swinging Comments: Repair or replace door that failed to open with less than
egress doors, other than fire doors, shall not exceed 5 15Ibs of force. Replacement of door requires permit and inspection
pounds (22 N). These forces do not apply to the force obtained.
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full-open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch-pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full-open position when
subjected to not more than a 15-pound (67 N) force.
GENERATED ON 6/11/26, 8:51 AM 2 OF 7
Additional Codes
Status Code Description
Fail 102.4-Application of building code.
OThe design and construction of new structures shall comply Location:Permit-6ft privacy fence
with the International Building Code,and any alterations, Comments:Contractor(Team Builders)shall obtain inspection of
additions,changes in use or changes in structures required work completed.Permit written Aug 7,2025
by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Fail 2015 IPMC 704.1.1-Automatic sprinkler systems
OInspection,testing and maintenance of automatic sprinkler Location:5 year sprinkler inspection
systems shall be in accordance with NFPA 25. Comments:Provide contractor inspection and correct any
deficiencies with report to be uploaded to Compliance Engine.
Currently 65 days past due.
Fail 5303.5.3-Securing compressed gas containers,cylinders
lJ and tanks. Location:Near back kitchen exit
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.Chain noted very loose to tank today.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
GENERATED ON 6/11/26, 8:51 AM 3 OF 7
Fail 603.1.1-Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment, Location:Kitchen-soup kettles next to Pepsi fridge
wiring,devices and appliances shall be tested;and listed by Comments:Remove appliances from plugged to multi-plug adapter.
an approved agency and labeled;and installed,used and Appliances including motors or heat producing elements shall plug
maintained in accordance with NFPA 70 and all instructions directly to wall outlet.
included as part of such listing.
•
I•
WOO .1
VIM
Fail 603.1.1-Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment, Location:Sushi bar
wiring,devices and appliances shall be tested;and listed by
Comments:Remove food warmer from plugged to multi-plug adapter.
an approved agency and labeled;and installed,used and Appliances including motors or heat producing elements shall plug
maintained in accordance with NFPA 70 and all instructions directly to wall outlet.
included as part of such listing.
Fail 606.3.1-Ventilation system.
The ventilation system in connection with hoods shall be Location:Kitchen exhaust hood
operated at the required rate of air movement,and grease Comments:Close multiple gaps in grease filters.Filters not in place
filters listed and labeled in accordance with UL 1046 shall be cause more grease in ductwork and on cables for fire suppression
in place where equipment under a kitchen grease hood is
used.
Emergency Equipment
���atus Code
Description
Fail 1203.2.15-Means of egress illumination.
Emergency power shall be provided for means of egress Location:Dining area
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:High bay egress lights shall be tested and repaired if
necessary.Provide documentation of,including signed and dated of
responsible person
General Housekeeping
Status Code Description
Fail 304.3.1-Spontaneous ignition.
Materials susceptible to spontaneous ignition,such as oily Location:Kitchen
rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container for disposal of oily rags,see
of such containers shall be removed and disposed of daily. attachement
GENERATED ON 6/11/26, 8:51 AN 4 OF 7
Fire Sprinkler System
Status Code Description
Fail 5.2.1.1.5-Missing escutcheons
Ux Escutcheons and coverplates for recessed,flush,and Location:Kitchen-hallway to dining area
concealed sprinklers shall be replaced if found missing Comments:Escutcheon shall be repaired to be tight,flush with
during the inspection. ceiling tile.
t-,
Fail 903.3.1-Standards.
OSprinkler systems shall be designed and installed in Location:Sprinkler riser room
accordance with Section 903.3.1.1,unless otherwise Comments:Did not gain access during 6110126 inspection.Provide
permitted by Sections 903.3.1.2 and 903.3.1.3 and other access to inspector on re-inspection.
chapters of this code,as applicable.
Fail 903.3.3-Obstructed locations.
Automatic sprinklers shall be installed with regard to Location:Kitchen-near office
obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head outside of
distribution pattern and shall be in accordance with the office
applicable automatic sprinkler system standard that is being
used.Automatic sprinklers shall be installed in or under
covered kiosks,displays,booths,concession stands or
equipment that exceeds 4 feet(1219 mm)in width.Not less
than a 3-foot(914 mm)clearance shall be maintained between
automatic sprinklers and the top of piles of combustible
fibers.Exception:Kitchen equipment under exhaust hoods
protected with a fire-extinguishing system in accordance with
Section 904.
Fire Service Features
Status Code Description
Fail 509.1-Identification.
Fire protection equipment shall be identified in an approved Location:Kitchen office door
manner.Rooms containing controls for air-conditioning Comments:Provide approved permanent"FACP"sign on door,
systems,sprinkler risers and valves,or other fire detection, laminated paper will not be accepted.
suppression or control elements fire protection systems shall
be identified for the use of the fire department.Approved
signs required to identify fire protection system equipment
and equipment location shall be constructed of durable
materials,permanently installed and readily visible.
GENERATED ON 6/11/26, 8:51 AM 5 OF 7
Commercial Cooking Hood Suppression System
Stat.is Code Description
Fail 606.3.3.2-Grease accumulation.
If during the inspection it is found that hoods,grease-removal Location:Kitchen
devices,fans,ducts or other appurtenances have an Comments:Clean excess grease noted on suppression lines above
accumulation of grease,such components shall be cleaned in cooking equipment under exhaust hood and behind hood filters.
accordance with ANSI!IKECA C10.