Loading...
HomeMy WebLinkAbout941 E SAN MARNAN DRIVE - IZUMI SUSHI RESTAURANT OF W 4 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE A - 4'( 06/18/2026 07/23/2026 2026-00000592 $80.00 o u rair��� l ) O 4S Customer#: 24976 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IZUMI SUSHI RESTAURANT 715 Mulberry St 941 E. SAN MARNAN DRIVE WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 941 E. SAN MARNAN DR.- FOR BILLING INQUIRY: (319)291-4323 06/10/2026 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24976 06/18/2026 07/23/2026 2026-00000592 $80.00 Less Prepayment $0.00 Total Due-p $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue NE Inspection Report /VFW 425 E.3rtl Street Izumi Sushi Restaurant-941 E San Marnan DR,BLDG 941 E San Marnan Dr, Waterloo IA 50702 INSPECTION DETAILS 9('4- Inspection Date Inspection Type C.i/l�/L'1y)) Inspection Number 0611012026 Annual Inspection(1Yr) 11224 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 053 014 012 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/02/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0611112026 @ 08:22 •$80 annual inspection fee BRAD BALDWIN-0611112026 @ 08:22 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06111/2026 @ 08:22 •Provide corrections to avoid progressive re-inspection fees beginning at$100.BeerlLiquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0 611112 02 6 @ 08:23 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.".**Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-06111/2026 @ 08:42 Corrected during 6110126 inspection-Removed heated water appliance from multi-plug adapter and plugged to wall outlet. SIGNATURES Contact signature Inspector signature No signature post Report completed post inspection Restaurant email 2026 Date: BRAD BALDWIN 0611112026 CHECKLISTS GENERATED ON 6/11/26,9:51 AN OF 7 Means of Egress Status Code Description Fail 1010.1.3- Door opening force Forces to unlatch and open doors. Location: Exit door near bathrooms The force for pushing or pulling open interior swinging Comments: Repair or replace door that failed to open with less than egress doors, other than fire doors, shall not exceed 5 15Ibs of force. Replacement of door requires permit and inspection pounds (22 N). These forces do not apply to the force obtained. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full-open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch-pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound (67 N) force. GENERATED ON 6/11/26, 8:51 AM 2 OF 7 Additional Codes Status Code Description Fail 102.4-Application of building code. OThe design and construction of new structures shall comply Location:Permit-6ft privacy fence with the International Building Code,and any alterations, Comments:Contractor(Team Builders)shall obtain inspection of additions,changes in use or changes in structures required work completed.Permit written Aug 7,2025 by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 2015 IPMC 704.1.1-Automatic sprinkler systems OInspection,testing and maintenance of automatic sprinkler Location:5 year sprinkler inspection systems shall be in accordance with NFPA 25. Comments:Provide contractor inspection and correct any deficiencies with report to be uploaded to Compliance Engine. Currently 65 days past due. Fail 5303.5.3-Securing compressed gas containers,cylinders lJ and tanks. Location:Near back kitchen exit Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over.Chain noted very loose to tank today. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. GENERATED ON 6/11/26, 8:51 AM 3 OF 7 Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Kitchen-soup kettles next to Pepsi fridge wiring,devices and appliances shall be tested;and listed by Comments:Remove appliances from plugged to multi-plug adapter. an approved agency and labeled;and installed,used and Appliances including motors or heat producing elements shall plug maintained in accordance with NFPA 70 and all instructions directly to wall outlet. included as part of such listing. • I• WOO .1 VIM Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Sushi bar wiring,devices and appliances shall be tested;and listed by Comments:Remove food warmer from plugged to multi-plug adapter. an approved agency and labeled;and installed,used and Appliances including motors or heat producing elements shall plug maintained in accordance with NFPA 70 and all instructions directly to wall outlet. included as part of such listing. Fail 606.3.1-Ventilation system. The ventilation system in connection with hoods shall be Location:Kitchen exhaust hood operated at the required rate of air movement,and grease Comments:Close multiple gaps in grease filters.Filters not in place filters listed and labeled in accordance with UL 1046 shall be cause more grease in ductwork and on cables for fire suppression in place where equipment under a kitchen grease hood is used. Emergency Equipment ���atus Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Dining area illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:High bay egress lights shall be tested and repaired if necessary.Provide documentation of,including signed and dated of responsible person General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container for disposal of oily rags,see of such containers shall be removed and disposed of daily. attachement GENERATED ON 6/11/26, 8:51 AN 4 OF 7 Fire Sprinkler System Status Code Description Fail 5.2.1.1.5-Missing escutcheons Ux Escutcheons and coverplates for recessed,flush,and Location:Kitchen-hallway to dining area concealed sprinklers shall be replaced if found missing Comments:Escutcheon shall be repaired to be tight,flush with during the inspection. ceiling tile. t-, Fail 903.3.1-Standards. OSprinkler systems shall be designed and installed in Location:Sprinkler riser room accordance with Section 903.3.1.1,unless otherwise Comments:Did not gain access during 6110126 inspection.Provide permitted by Sections 903.3.1.2 and 903.3.1.3 and other access to inspector on re-inspection. chapters of this code,as applicable. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Kitchen-near office obstructions that will delay activation or obstruct the water Comments:Remove dust and debris from sprinkler head outside of distribution pattern and shall be in accordance with the office applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fire Service Features Status Code Description Fail 509.1-Identification. Fire protection equipment shall be identified in an approved Location:Kitchen office door manner.Rooms containing controls for air-conditioning Comments:Provide approved permanent"FACP"sign on door, systems,sprinkler risers and valves,or other fire detection, laminated paper will not be accepted. suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. GENERATED ON 6/11/26, 8:51 AM 5 OF 7 Commercial Cooking Hood Suppression System Stat.is Code Description Fail 606.3.3.2-Grease accumulation. If during the inspection it is found that hoods,grease-removal Location:Kitchen devices,fans,ducts or other appurtenances have an Comments:Clean excess grease noted on suppression lines above accumulation of grease,such components shall be cleaned in cooking equipment under exhaust hood and behind hood filters. accordance with ANSI!IKECA C10. GENERATED ON 6/11/26, 8:51 AM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/11/26, 8:51 AM 7 OF 7