HomeMy WebLinkAboutLDN Properties - 918 GRANT STREET LiW P(OPeA4
Waterloo Fire Rescue 1,0
I 07) SWO
s. � Inspection Report 425 E.3rd Street
BLDG 918 GRANT AVE-918 Grant AVE,Waterloo IA 50702-2204 �py �
INSPECTION DETAILS
Inspection Date Inspection Type..>-- Inspection Number
06124/2026 2015 IPMC Rental Inspection REINSPECTION
pe ction CS—O 21277-R1
Lead Inspector Shift :: Unit
MIKE HEERKES NIA NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
� 0 L 30
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
MIKE HEERKES
07/24/2026
mike.heerkes@waterloo-ia.org,3192914319
GENERAL NOTES
MIKE HEERKES-0312612026 @ 10:01
All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections.
MIKE HEERKES-03/26/2026 @ 10:01
Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unitls.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a S100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at S50,then S150,
and S250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
MIKE HEERKES-0312612026 @ 10:01
Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten
years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
LDN PROPERTIES Date: MIKE HEERKES 06/24/2026
CHECKLISTS
GENERATED ON 6/24/26, 3:31 PM
1 GF r
Reinspection
Sta:us Code Description
Fail 2015 IPMC 302.7-Accessory structures
Accessory structures,including detached garages,fences Location:Garage
and walls,shall be maintained structurally sound and in good Comments:Exterior in disrepair with loose,flaking,abraded paint.
repair.
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Living room
sound condition,good repair and weather tight. Comments:Window at bottom of stairs and window on opposite wall
have broken glass that needs to be replaced
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Bedroom#4
sound condition,good repair and weather tight. Comments:Window has broken glass.Needs to be repaired
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Front porch
sound condition,good repair and weather tight. Comments:Window missing glass has and replaced with plywood.
Window with broken glass.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Rear entrance
provided,and hardware shall be maintained in good Comments:Door only latches with dead bolt.
condition.Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front porch
provided,and hardware shall be maintained in good Comments:Storm door missing closing mechanism and latch
condition.Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front porch
provided,and hardware shall be maintained in good Comments:Entry door between porch and living room has broken
condition.Locks at all entrances to dwelling units and frame.
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Rear entrance
provided,and hardware shall be maintained in good Comments:Exterior door does not latch unless dead bolt lock is
condition.Locks at all entrances to dwelling units and engaged.
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.16-Basement hatchways
Every basement hatchway shall be maintained to prevent the Location:Basement
entrance of rodents,rain and surface drainage water. Comments:Hatch opening not weather tight and needs to be weather
resistant material
Fail 2015 IPMC 304.6-Exterior walls
Exterior walls shall be free from holes,breaks,and loose or Comments:Missing sections of siding on side of structure
rotting materials;and maintained weatherproof and properly
surface coated where required to prevent deterioration,
2 OF 7
GENERATED ON 6/24/26, 3:31 PM
Fail 2015 IPMC 304.7 - Roofs and drainage
The roof and flashing shall be sound, tight and not have Comments: Downspouts need to be extended to divert water away
defects that admit rain. Roof drainage shall be adequate to from foundation of building
prevent dampness or deterioration in the walls or interior
portion of the structure. Roof drains, gutters and downspouts
shall be maintained in good repair and free from obstructions.
Roof water shall not be discharged in a manner that creates a
public nuisance.
Fail 2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be Location: Basement stairway
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed Comments: Ceiling area with missing plaster.
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3 - Interior surfaces
Interior surfaces, including windows and doors, shall be Location: Hallway of second floor, Bathroom
maintained in good, clean and sanitary condition. Peeling,
chipping, flaking or abraded paint shall be repaired, removed Comments: Floor coverings in disrepair with areas of
or covered. Cracked or loose plaster, decayed wood and weak/deteriorated subfloor causing trip hazards.
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3 - Interior surfaces
OX Interior surfaces, including windows and doors, shall be Location: Bathroom
maintained in good, clean and sanitary condition. Peeling,
Comments: Area of wall under sink patched with inappropriate
chipping, flaking or abraded paint shall be repaired, removed material (duct tape)
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3 - Interior surfaces
Ox Interior surfaces, including windows and doors, shall be Location: Bedroom #4
maintained in good, clean and sanitary condition. Peeling,
Comments: Walls in disrepair and missing transition strip in door
chipping, flaking or abraded paint shall be repaired, removed
way causing trip hazard.
or covered. Cracked or loose plaster, decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.6 - Interior doors
Ox Every interior door shall fit reasonably well within its frame Location: Bedroom #3
and shall be capable of being opened and closed by being Comments: Door knob assembly loose not functioning as intended
properly and securely attached to jambs, headers or tracks as
intended by the manufacturer of the attachment hardware.
Fail 2015 IPMC 307.1 - General - Handrails & Guards
Ox Every exterior and interior flight of stairs having more than Location: Stairway to second floor
four risers shall have a handrail on one side of the stair and Comments: Top flight of steps missing handrail
every open portion of a stair, landing, balcony, porch, deck,
ramp or other walking surface that is more than 30 inches
(762 mm) above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches (762 mm) in height
or more than 42 inches (1067 mm) in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces. Guards shall be not
less than 30 inches (762 mm) in height above the floor of the
landing, balcony, porch, deck, or ramp or other walking
surface.
GENERATED ON 6/24/26, 3:31 PM 3 OF 7
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
0 Requirements Location:Bathroom
Plumbing fixtures shall be properly installed and maintained Comments:Sink has corner missing and at time of inspection toilet
in working order,and shall be kept free from obstructions, did not function properly.
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
Fail 2015 IPMC 603.1-Mechanical appliances
Mechanical appliances,fireplaces,solid fuel-burning Location:Kitchen
appliances,cooking appliances and water heating appliances Comments:Stove has broken cook surface.
shall be properly installed and maintained in a safe working
condition,and shall be capable of performing the intended
function.
Fail 2015 IPMC 603.2-Removal of combustion products
Fuel-burning equipment and appliances shall be connected to Location:Basement
an approved chimney or vent.Exception:Fuel-burning Comments:Clothes dryer not vented to the outside
equipment and appliances that are labeled for unvented
operation.
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less Location:Bedroom#1
than two separate and remote receptacle outlets.Every Comments:Receptacles indicated open ground when tested.
laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Stairway to second floor
bathroom,laundry room,boiler room and furnace room shall Comments:Missing light bulb in fixture.
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 605.3-Luminaires
Every public hall,interior stairway,toilet room,kitchen, Location:Bedroom#1,Bathroom,Bedroom#2,Bedroom#4,
bathroom,laundry room,boiler room and furnace room shall Comments:Ceiling light fixture missing appropriate globelcover.
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1
OSingle or multiple-station smoke alarms shall be installed and Location:First floor
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:No smoke detector present
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and Without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
GENERATED ON 6/24/28, 3:31 PM 4 OF 7
Fail 2015 IPMC 704.2.1.2- Groups R-2, R-3, R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location: Second floor, all bedrooms and hallway.
maintained in Groups R-2, R-3, R-4 and t-1 regardless of Comments: No working smoke detectors present in any of the
occupant load at all of the following locations: 1. On the required locations.
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2- Groups R-2, R-3, R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location: Basement
maintained in Groups R-2, R-3, R-4 and I-1 regardless of
Comments: Detector is required in this location.
occupant load at all of the following locations: 1. On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2. In each room used for
sleeping purposes. 3. In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R315.3 - Carbon Monoxide Detection: Location
Carbon monoxide alarms in dwelling units shall be installed Location: Second floor
outside of each separate sleeping area in the immediate Comments: No carbon monoxide detector in hallway
vicinity of the bedrooms. Where a fuel-burning appliance is
located within bedroom or its attached bathroom, a carbon
monoxide alarm shall be installed within the bedroom.
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards. Location: Basement
Identified electrical hazards shall be abated. Identified Comments: GFCI receptacle under electrical service panel not
hazardous electrical conditions in permanent wiring shall be working as intended.
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards. Location: Basement
Identified electrical hazards shall be abated. Identified Comments: Spliced wire connection needs to be in outlet box with
hazardous electrical conditions in permanent wiring shall be appropriate cover.
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 6/24/26, 3:31 PM 5 OF 7
Fail 603.2-Abatement of unsafe conditions and electrical
hazards. Location:Basement
Identified electrical hazards shall be abated.Identified Comments:Existing outlet box with exposed wiring missing
hazardous electrical conditions in permanent wiring shall be appropriate cover.
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 5/24/26, 3:31 FM 6 OF 7
.r
Po Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $50.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 6/24/26, 3:31 PM 7 OF 7
OF W TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE
e=�( 07/01/2026 08/05/2026 2027-00000004 $50.00
4-1O
• '111 IN II 111 11 II •
T 0
4S 7vilN
Customer#: 22306 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
LDN PROPERTIES L L C 715 Mulberry St
PO BOX 2094 WATERLOO, IA 50703
Waterloo, IA 50704
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION - 918 GRANT ST- 06/24/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
22306 07/01/2026 08/05/2026 2027-00000004 $50.00
Less Prepayment $0.00
Total Due -* $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.