HomeMy WebLinkAboutCALIBER MANAGEMENT - 406 RIEHL STREET • • CO,I1111 (6-rp� 10
Waterloo Fire Rescue Vd F'f0 ecS S4
Inspection Report U
I 425 E.3rd Street
BLDG 406 RIEHL ST•406 Riehl ST,Waterloo IA 50703 cO
TO INSPECTION DETAILS
Inspection Date Inspection Tye Inspection Number
0612312026 2015 IP Egia spection REINSPECTION a4wa --2247E-R1
Lead Inspector Shift Station Unit
MIKE HEERKES NIA NIA NIA
Other Inspectors
N/A
SUMMARY OF INSPECTION
0 0 0 2 0 13
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
MIKE HEERKES
mike.heerkes@waterloo-ia.org,3192914319 0712412026
GENERAL NOTES
MIKE HEERKES-05/2112026 @ 12:20
All structural repairs,roofing,window replacement,exterior door replacement,water heater replacement,furnace replacement and major electrical
repairs require appropriate permits and inspections.
MIKE HEERKES-0 512 112 0 2 6 @ 12:20
Reinspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
MIKE HEERKES•0512112026 @ 12:20
Iowa Administrative Code 661-210.3(7)d.After June 30,2021,a battery-powered smoke alarm listed in accordance with UL 217 that is newly installed or
replaces an existing battery-powered smoke alarm must be powered by a nonremovable,non-replaceable battery that powers the alarm for at least ten
years.The battery requirements of this subrule do not apply to a fire alarm,smoke detector,smoke alarm,or ancillary component that is electronically
connected as a part of a centrally monitored or supervised alarm system;that uses a low-power,radio frequency wireless communication signal.
SIGNATURES
Contact signature Inspector signature
,���,,.I/////��
No signposre / I
Report completed post inspection /
Caliber Group Date: MIKE HEERKES 0 6/2412 0 2 6
CHECKLISTS
GENERATED ON 6/24/26,9:19 AM 1 OF 5
Reinspection
Sta:us Code Description
Fail 2015 IPMC 304.13-Window,skylight and door frames
Every window,skylight,door and frame shall be kept in Location:Kitchen
sound condition,good repair and weather tight. Comments:Window with broken glass and torn screen.
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Living room
openable and capable of being held in position by window Comments:Window on east wall needs to be able to be opened and
hardware remain opened.
Fail 2015 IPMC 304.3-Premises identification
Buildings shall have approved address numbers placed in a Comments:Address numbers faded
position to be plainly legible and visible from the street or
road fronting the property.These numbers shall contrast with
their background.Address numbers shall be Arabic numerals
or alphabet letters.Numbers shall be not less than 4 inches
(102 mm)in height with a minimum stroke width of 0.5 inch
(12.7 mm).
Fail 2015 IPMC 305.4-Stairs and walking surfaces
Every stair,ramp,landing,balcony,porch,deck or other Location:Stairs to second floor
walking surface shall be maintained in sound condition and Comments:Bull nosing on step not connected properly
good repair.
Fail 2015 IPMC 305.4-Stairs and walking surfaces
Ox Every stair,ramp,landing,balcony,porch,deck or other Location:Stairway to second floor
walking surface shall be maintained in sound condition and Comments:Wire(possible telephone? loose extending
good repair. P ) into walkway
of stairs needs to be removed or placed in conduit and secured to
wall.
Resolved 2015 IPMC 308.2.2-Refrigerators
O✓ Refrigerators and similar equipment not in operation shall not Location:Basement
be discarded,abandoned or stored on premises without first Comments:Chest freezer that is not operational needs to be
removing the doors. removed.
Fail 2015 IPMC 403.2-Bathrooms and toilet rooms
Every bathroom and toilet room shall comply with the Location:Second floor bathroom
ventilation requirements for habitable spaces as required by Comments:Window does not open.
Section 403.1,except that a window shall not be required in
such spaces equipped with a mechanical ventilation system.
Air exhausted by a mechanical ventilation system from a
bathroom or toilet room shall discharge to the outdoors and
shall not be recirculated.
Resolved 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
Requirements Location:Kitchen
Plumbing fixtures shall be properly installed and maintained Comments:Faucet leaking from aerator connection.
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
GENERATED ON 6/24/26, 9:19 AM 2 OF 5
•
Fail 2015 IPMC 505.4-Water heating facilities
OX Water heating facilities shall be properly installed,maintained Location:Basement
and capable of providing an adequate amount of water to be Comments:Water heater installed without permit or inspection.Have
drawn at every required sink,lavatory,bathtub,shower and licensed plumber bring up to current code with appropriate permits
laundry facility at a minimum temperature of 110°F(43°C).A and inspections
gas-burning water heater shall not be located in any
bathroom,toilet room,bedroom or other occupied room
normally kept closed,unless adequate combustion air is
provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be
properly installed and maintained on water heaters
Fail 2015 IPMC 603.1-Mechanical appliances
l^/ Mechanical appliances,fireplaces,solid fuel-burning Location:Basement
appliances,cooking appliances and water heating appliances Comments:Furnace drain line is disconnected.
shall be properly installed and maintained in a safe working
condition,and shall be capable of performing the intended
function.
Fail 2015 IPMC 605.1-Installation
OElectrical equipment,wiring and appliances shall be properly Location:Both front and rear entrances
installed and maintained in a safe and approved manner. Comments:Exterior lights are missing appropriate globeslcovers
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
OSingle or multiple-station smoke alarms shall be installed and Location:Basement and outside of bedrooms on second floor
maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Smoke detectors were not found at time of inspection
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed Location:Second floor outside of bedrooms
outside of each separate sleeping area in the immediate Comments:Detector not observed at time of inspection.
vicinity of the bedrooms.Where a fuel-burning appliance is
located within bedroom or its attached bathroom,a carbon
monoxide alarm shall be installed within the bedroom.
Fail 603.2-Abatement of unsafe conditions and electrical
0 hazards. Location:Bottom of stairs to second floor
Identified electrical hazards shall be abated.Identified Comments:Light switch fatigued needs replaced
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 6/24/28, 9:19 AM 3 OF 5
Fail 603.2 - Abatement of unsafe conditions and electrical
0 hazards. Location: Bedroom #1
Identified electrical hazards shall be abated. Identified Comments: Receptacle by light switch indicates open ground when
hazardous electrical conditions in permanent wiring shall be tested
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 6/24/26, 9:19 AM
4 OF 5
'o Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
N/A $50.00
Invoice Number Check Number Transaction Number
N/A NIA NIA
GENERATED ON 6/24/26, 9:19 AM 5 OF 5
W q T INVOICE DATE DUE DATE INVOICE# TOTAL DUE
O F,P A L y e 07/01/2026 08/05/2026 2027-00000008 $50.00
L o
• *1 ■ O 1 .1 •
T T O
7V17‘7
Customer#: 24620 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
CALIBER MANAGEMENT 715 Mulberry St
622 PROGRESS AVE WATERLOO, IA 50703
STE B
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION -406 RIEHL ST- 06/23/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24620 07/01/2026 08/05/2026 2027-00000008 $50.00
Less Prepayment $0.00
Total Due-p $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.