HomeMy WebLinkAboutWENDELL GAINES - 250 WESTERN AVENUE Waterloo Fire Rescue 0*1
Inspection Report weida ( 425 E.3rd Street
BLDG 250 Western Avenue-250 Western AVE,Waterloo IA 50701-2634 r, Q ��S,.jc-C�,
Jl Aire .
INSPECTION DETAILS Lot ���p
Inspection Date Inspection Type Inspection Number
06/08/2026 2015IPMC Rental Inspection Q I J C/L/ 154 Do 22775
Lead Inspector Shift Station Unit
NATE BEUSELING N/A N/A N/A
Other Inspectors
Randy Girsch
SUMMARY OF INSPECTION
00 023 ® 34
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
NATE BEUSELING
07/09/2026
nate.beuseling@waterloo-ia.org
GENERAL NOTES
NATE BEUSELING-06/09/2026 C 15:38
Inspection due to tenant complaint,at time of inspection it was noted several windows broke out on both main floor and upstairs area,basement stairs
unsuitable for use due to deterioration and egress blocking materials,several light switch covers missing,one in floor burnt,upstairs bathroom in
disrepair including shower,drywall,and overly hot water not able to be adjusted due to dilapidated basement stairs,kitchen sink backed up,floor wet
from waterline running from basement to fridge that is no longer there,no working smoke alarms present,front door to porch is blocked,and porch is full
of belongings making fire escape impossible,along with windows busted on front porch aswell,back door to property in disrepair along with dilapidated
drywall throughout property,upstairs bedrooms have no smoke detectors present and one bedroom showing signs of mold substance and drywall
ceiling damaged caused by potential leak,bedroom doors do not function properly with one door being able to shut but cannot open back up from inside,
outlets read anywhere from open ground to hot neutral reverse,exterior decks have loose railings and front porch has broken trust beams supporting it,
rental unit is being found not fit for rental occupancy and rental occupancy can only be gained by fully passing a rental inspection
NATE BEUSELING-06/09/2026 @ 15:39
At time of inspection unit was a active rental unit not registered with the City a 5100.00 fee applied
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Wendell Gaines Date: NATE BEUSELING 06/09/2026
CHECKLISTS
GENERATED ON 6/9/26, 3:40 PM 1 OF 7
2015 IPMC Unsafe Structures and Equipment
Status Code Description
Fail 2015 IPMC 108.1.1-Unsafe structures
Ox Unsafe structures.An unsafe structure is one that is found to
be dangerous to the life,health,property or safety of the
public or the occupants of the structure by not providing
minimum safeguards to protect or warn occupants in the
event of fire,or because such structure contains unsafe
equipment or is so damaged,decayed,dilapidated,
structurally unsafe or of such faulty construction or unstable
foundation,that partial or complete collapse is possible.
Fail 2015 IPMC 108.1.2-Unsafe equipment
OUnsafe equipment includes any boiler,heating equipment,
elevator,moving stairway,electrical wiring or device,
flammable liquid containers or other equipment on the
premises or within the structure which is in such disrepair or
condition that such equipment is a hazard to life,health,
property or safety of the public or occupants of the premises
or structure.
Fail 2015 IPMC 108.1.3-Structure unfit for human occupancy
A structure is unfit for human occupancy whenever the code
official finds that such structure is unsafe,unlawful or,
because of the degree to which the structure is in disrepair or
lacks maintenance,is insanitary,vermin or rat infested,
contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential
equipment required by this code,or because the location of
the structure constitutes a hazard to the occupants of the
structure or to the public.
GENERATED ON 6/9/26, 3:40 PM 2 OF 7
2015 IPMC Exterior Property
Status Code Description
Fail 2015 IPMC 304.18-Building security
0 Doors,windows or hatchways for dwelling units,room units
or housekeeping units shall be provided with devices
designed to provide security for the occupants and property
within.
Fail 2015 IPMC 304.18.2-Windows
OOperable windows located in whole or in part within 6 feet
(1828 mm)above ground level or a walking surface below that
provide access to a dwelling unit,rooming unit or
housekeeping unit that is rented,leased or let shall be
equipped with a window sash locking device.
Fail 2015 IPMC 304.7-Roofs and drainage
OThe roof and flashing shall be sound,tight and not have
defects that admit rain.Roof drainage shall be adequate to
prevent dampness or deterioration in the walls or interior
portion of the structure.Roof drains,gutters and downspouts
shall be maintained in good repair and free from obstructions.
Roof water shall not be discharged in a manner that creates a
public nuisance.
Fail 2015 IPMC 307.1-General-Handrails&Guards
Every exterior and interior flight of stairs having more than
four risers shall have a handrail on one side of the stair and
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
GENERATED ON 6/9/26, 3:40 PM 3 OF 7
2015 IPMC Egress Components
Status Code Description
Fail 2015 IPMC 304.15-Doors
OExterior doors,door assemblies,operator systems if
provided,and hardware shall be maintained in good
condition.Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door.Locks on means
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 305.4-Stairs and walking surfaces
OEvery stair,ramp,landing,balcony,porch,deck or other
walking surface shall be maintained in sound condition and
good repair.
Fail 2015 IPMC 307.1-General-Handrails&Guards
0 Every exterior and interior flight of stairs having more than
four risers shall have a handrail on one side of the stair and
every open portion of a stair,landing,balcony,porch,deck,
ramp or other walking surface that is more than 30 inches
(762 mm)above the floor or grade below shall have guards.
Handrails shall be not less than 30 inches(762 mm)in height
or more than 42 inches(1067 mm)in height measured
vertically above the nosing of the tread or above the finished
floor of the landing or walking surfaces.Guards shall be not
less than 30 inches(762 mm)in height above the floor of the
landing,balcony,porch,deck,or ramp or other walking
surface.
2015 IPMC Interior Property
Status Code Description
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition.Peeling,
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.4-Stairs and walking surfaces
OEvery stair,ramp,landing,balcony,porch,deck or other
walking surface shall be maintained in sound condition and
good repair.
2015 IPMC Rubbish &Garbage
Status Code Description
Fail 2015 IPMC 308.1-Accumulation of rubbish or garbage
OExterior property and premises,and the interior of every
structure,shall be free from any accumulation of rubbish or
garbage.
2015 IPMC Pest Elimination
Status Code Description
Fail 2015 IPMC 309.1-Infestation
OStructures shall be kept free from insect and rodent
infestation.Structures in which insects or rodents are found
shall be promptly exterminated by approved processes that
will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent reinfestation.
ao= 7
GENERATED ON 6/9/26, 3:40 PM
2015 IPMC Ventilation
Status Code Description
Fail 2015 IPMC 403.2-Bathrooms and toilet rooms
OEvery bathroom and toilet room shall comply with the
ventilation requirements for habitable spaces as required by
Section 403.1,except that a window shall not be required in
such spaces equipped with a mechanical ventilation system.
Air exhausted by a mechanical ventilation system from a
bathroom or toilet room shall discharge to the outdoors and
shall not be recirculated.
2015 IPMC Water System
Status Code Description
Fail 2015 IPMC 504.1-General-Plumbing Facilities and Fixture
ORequirements
Plumbing fixtures shall be properly installed and maintained
in working order,and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional
condition
Fail 2015 IPMC 505.1-General-Water System
OEvery sink,lavatory,bathtub or shower,drinking fountain,
water closet or other plumbing fixture shall be properly
connected to either a public water system or to an approved
private water system.Kitchen sinks,lavatories,laundry
facilities,bathtubs and showers shall be supplied with hot or
tempered and cold running water in accordance with the
International Plumbing code
2015 IPMC Electrical
Status Code Description
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less
than two separate and remote receptacle outlets.Every
laundry area shall contain not less than one grounding-type
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.3-Luminaires
OEvery public hall,interior stairway,toilet room,kitchen,
bathroom,laundry room,boiler room and furnace room shall
contain not less than one electric luminaire.Pool and spa
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 603.2-Abatement of unsafe conditions and electrical
0 hazards.
Identified electrical hazards shall be abated.Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
GENERATED ON 6/9/26, 3:40 PM 5 OF
2015 IPMC Fire Protection
Status Code Description
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1-1
OSingle or multiple-station smoke alarms shall be installed and
maintained in Groups R-2,R-3,R-4 and I-1 regardless of
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R 314.1.1-Smoke Alarms:Listings
Smoke alarms shall be listed in accordance with UL 217.
Combination smoke and carbon monoxide alarms shall be
listed in accordance with 217 and UL 2034
Fail 20211RC R315.3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed
outside of each separate sleeping area in the immediate
vicinity of the bedrooms.Where a fuel-burning appliance is
located within bedroom or its attached bathroom,a carbon
monoxide alarm shall be installed within the bedroom.
6OF7
GENERATED ON 6/9/26, 3:40 PM
Statement of Fees
FEE
invoice Date Inspection Fee Date Paid Amount Paid
N/A $100.00
Invoice Number Check Number Transaction Number
N/A N/A N/A
GENERATED ON 6/9/26, 3:40 PN 7 OF 7
OF W III qI TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE
�� 07/01/2026 08/05/2026 2027-00000003 $150.00
Il.IIl I I
T- T Oo•
Customer#: 24985 Please Make Check Payable and Remit To:
City of Waterloo
ATTN:: City Clerk/Accounts Receivable
WENDELL GAINES 715 Mulberry St
250 WESTERN AVENUE WATERLOO, IA 50703
WATERLOO,IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL PROP INSPECTION - 250 WESTERN AVE- 06/08/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
REINSPECTION FEE 1ST $50.00
FAILURE TO OBTAIN PERMIT $100.00
CUSTOMER# BILLING DATE DUE DATE _ INVOICE# CHARGES
24985 07/01/2026 08/05/2026 2027-00000003 $150.00
Less Prepayment $0.00
Total Due--> $150.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.