Loading...
HomeMy WebLinkAboutHOMETOWN CAS ADVANCE-323 FRANKLIN ST Waterloo Fire Rescue bk ) Inspection Report 425 E.3rd Street Hometown Cash Advance-323 Franklin ST,BLDG 323 Franklin St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 06126/2026 Annual Inspection(1Yr) 0 a ?OP:, 532 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 031 06 ® 38 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/30/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0613012026 @ 06:38 •$80 annual inspection fee BRAD BALDWIN-0613012026 @ 06:38 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06130/2026 @ 06:38 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature post Kty: Report completed post inspection Mike Tiggelar-2026 Date: BRAD BALDWIN 06130/2026 CHECKLISTS GENERATED ON 6/30/26, 8:04 AM 1 OF 5 Additional Codes Status Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Back exit doors where any of the following exist 1.Places of detention Comments:Not more than a single motion allowed to unlatch and or restraint.2.In Group 1.1,Condition 2 and Group 1-2 unlock door to exit.Options:(1)Remove all hardware not In occupancies where the clinical needs of persons receiving compliance to code.(2)Second exit not required per occupancy and care require containment or where persons receiving care approved by City Permit Writer,Jennifer Sparks to remove all exit pose a security threat,provided that all clinical staff can signage directing towards back(north)exit including capping readily unlock doors at all times,and all such locks are keyed electrical wires and containing in box with cover.Removing exit to keys carried by all clinical staff at all times or all clinical signage allows all(north)door hardware to remain as is currently. staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.&Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key. operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 6/30/26, 8:04 Mt 2 OF 5 Emergency Equipment Status Code Description Fail 1203.2.6 - Exit signs. Ox Emergency power shall be provided for exit signs as required Location: Back exit in Section 1013.6.3. The system shall be capable of powering Comments: Options: (1) Repair or replace exit sign that failed to the required load for a duration of not less than 90 minutes. illuminate during test. (2) Second exit not required per occupancy and approved by City Permit Writer, Jennifer Sparks to remove all exit signage directing towards back (north) exit including capping electrical wires and containing in box with cover. Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required Location: Front exit in Section 1013.6.3. The system shall be capable of powering Comments: Repair or replace exit sign and egress lights combo that the required load for a duration of not less than 90 minutes, failed to illuminate during test Electrical Safety Status Code Description Fail 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked Location: Electric panel with a plainly visible and legible sign stating "ELECTRICAL Comments: Provide approved permanent signage on door to panel ROOM" or similar approved wording. The disconnecting closet indicating location of panel. Laminated paper will not be means for each service, feeder or branch circuit originating accepted. on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.2 - Application and usePower supply. ax Relocatable power taps and current taps shall be directly Location: Below register counter connected to a permanently installed receptacle. Exceptions: Comments: Multiple power strips daisy chained one from another, 1. Where approved for use in a Group A occupancy or in a each individual power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy, not more than five All power strips shall include manual reset, be properly mounted and relocatable power taps shall be permitted to be connected be used for low wattage electronics only. together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 6/30/26, 8:04 AM 3 OF 5 Portable Fire Extingusihers stay_,s Cod, Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Extinguisher maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,currently no tag Exceptions:1.The distance of travel to reach an extinguisher with date. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 6/30/26, 8:04 AM 4 OF 5 Elo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number N►A N►A NIA GENERATED ON 6/30/26, 8:04 AM 5 OF 5 OF WA pF INVOICE DATE DUE DATE INVOICE# TOTAL DUE '': 0 06/30/2026 08/05/2026 2026-00000595 $80.00 v.,ffffoc /� O T--- ♦ O Customer#: 10855 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CASH ADVANCE 715 Mulberry St 2842 UNIVERSITY WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-323 FRANKLIN ST- 06/26/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10855 06/30/2026 08/05/2026 2026-00000595 $80.00 Less Prepayment $0.00 Total Due-p $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.