HomeMy WebLinkAboutHUNDRED TICKET VISION, LLC-3769 W. 9TH ST Pafidieele-Thje-1,1 05/00 Waterloo Fire Rescue a`i 0 7� (, � / cyc. s6 �;P s Inspection Report v�V� V /i/ -T/ 425 E.3rd Street BLDG 3769 West 9th Street-3769 W 9th ST,Waterloo'IA 50702 �7Y INSPECTION DETAILS Inspection Date Inspection Type t-t047CO ! Inspection Number 06125/2026 Residential Common Areas Inspection REINSPECTION T I l I0 d° 21044-R2 Lead Inspector Shift Station Unit NATE BEUSELING NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 0 0 13 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING 07/27/2026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-06/25/2026 @ 10:06 Reinspection scheduled through Jeff Seibel and myself through Amy Mullins in may for this date,confirmation email was sent to her on Wednesday 6124/2026 with no answer and no show for reinspection,100.00 fee no charge per unit will reset for 30 days and reschedule JEFF SIEBEL-04120/2026 @ 10:51 Re-inspection date is as posted on the inspection report.The rental unit's responsible personls shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. JEFF SIEBEL-04120/2026 @ 10:51 Fire Alarm inspected 2125126 by Proshield JEFF SIEBEL-0412012026 @ 10:51 Dryer vent cleaned by Listy Wickham 2/13/26 JEFF SIEBEL-04/20/2026 @ 10:51 Some items are included from complaint inspection on 12118125 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection MGT Property Management Date: NATE BEUSELING 06/25/2026 GENERATED ON 6/25/26, 10:07 AN 1 OF 5 CHECKLISTS GENERATED ON 6/25/26, 10:07 AM 2 OF 5 Reinspection Status Code Description Fail 2015 IPMC 304.6-Exterior walls OExterior walls shall be free from holes,breaks,and loose or Location:Electrical panel cover doors rotting materials;and maintained weatherproof and properly Comments:Doors must be re-attached and made water resistent. surface coated where required to prevent deterioration. Electric panels not rated to weather exposure. Fail 2015 IPMC 305.3-Interior surfaces QInterior surfaces,including windows and doors,shall be Location:3rd floor common area maintained in good,clean and sanitary condition.Peeling, Comments:Paint and seal wall. chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 308.1-Accumulation of rubbish or garbage Ox Exterior property and premises,and the interior of every Location:Dumpsters outside structure,shall be free from any accumulation of rubbish or Comments:Pick up garbage and place in dumpster. garbage. Fail 2015 IPMC 704,2.1.2-Groups R-2,R-3,R-4 and I.1 Single or multiple-station smoke alarms shall be installed and Location:West entry 1st floor maintained in Groups R•2,R-3,R-4 and I-1 regardless of Comments:Replace missing smoke detector.Repairlreplace dual occupant load at all of the following locations:1.On the sensor smoke detector.All smokelCO detectors must be UL listed ceiling or wall outside of each separate sleeping area in the and new detectors must be 10 year sealed batteries immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1 Single or multiple-station smoke alarms shall be installed and Location:2nd Floor stairway maintained in Groups R-2,R-3,R-4 and I.1 regardless of Comments:Replace missing smoke detector.Repairlreplace dual occupant load at all of the following locations:1.On the sensor smoke detector.All smokelCO detectors must be UL listed ceiling or wall outside of each separate sleeping area in the and new detectors must be 10 year sealed batteries immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Single or multiple-station smoke alarms shall be installed and Location:East 2nd floor stairs maintained in Groups R-2,R-3,R-4 and I.1 regardless of Comments:Replace missing smoke detector.Repairlreplace dual occupant load at all of the following locations:1.On the sensor smoke detector.All smoke/CO detectors must be UL listed ceiling or wall outside of each separate sleeping area in the and new detectors must be 10 year sealed batteries immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not Including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level GENERATED ON 8/25/28,10:07 AN 3 OF 5 Fail 506.1-Where required. Where access to or within a structure or an area is restricted Location:Front of building because of secured openings or where immediate access is Comments:Install knox box with keys to all doors for fire fighter necessary for life-saving or fire-fighting purposes,the fire access.Contact Inspector JD Vandyke 319-291-4460 for location and code official is authorized to require a key box to be installed to lock keys in knox box. in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:In closet under West stairs prohibited.Approved covers shall be provided for all switch Comments:Install lamp in open socket of light fixture. and electrical outlet boxes. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:2nd floor East prohibited.Approved covers shall be provided for all switch Comments:repair light fixture,install missing cover and electrical outlet boxes. Fail 703.1-Maintaining protection. Materials and firestop systems used to protect membrane and Location:2nd Floor East fire door. through penetrations in fire-resistance-rated construction and Comments:Replace missingsmoke seal with construction installed to resist the passage of smoke shall be p approved material. maintained.The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:1st floor closet under West stairs materials and systems used to protect joints and voids in the Comments:repair hole in wall under stairs with sheetrock. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3,Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7,Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 705.2.4-Door operation. 0 Swinging fire doors shall close from the full-open position Location:1st floor and all floors including both fire doors on 3rd floor and latch automatically. corridor. Comments:All Fire doors must completely self-close and latch on all floors Fail 99999-Inspection Outcome Did the inspection pass or tail? GENERATED ON 6/25/26, 10:07 AM 4 OF 5 El Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA S100.00 Invoice Number Check Number Transaction Number N/A NIA NIA • 5 OF 5 GENERATED ON 6/25/26, 10:07 AM OF WA rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 06/30/2026 08/05/2026 2026-00000609 $100.00 u„iiai••.. .: 1 0 )dii$15 FS 7vil‘ Customer#: 24076 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HUNDRED TICKET VISION LLC 715 Mulberry St PO BOX 56 WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3769 W. 9TH ST- 06/25/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24076 06/30/2026 08/05/2026 2026-00000609 $100.00 Less Prepayment $0.00 Total Due--> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days.