Loading...
HomeMy WebLinkAboutNAREY' 19TH HOLE 2073 LOGAN AV OF WA r INVOICE DATE DUE DATE INVOICE# TOTAL DUE TA 07/15/2026 08/19/2026 2027-00000012 $80.00 V„/////Q,• 1 A o • 111 ■11 I11 1 11 • T=T O Customer#: 3441 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable NAREY'S 19TH HOLE 715 Mulberry St 2073 LOGAN AV WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2073 LOGAN AVE-07/06/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3441 07/15/2026 08/19/2026 2027-00000012 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue €4,.',1 Inspection Report 425 E.3rd Street Narey's 19th Hole•2073 Logan AVE,BLDG 2073 Logan Ave,Waterloo IA 50703 INSPECTION DETAILS Inspection Date inspection Type Inspection Number 07/06/2026 Annual Inspection(1Yr) 314 I 4 op;co 17610 Lead Inspector Shift Station Unit BRAD BALDWIN N/A N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 33 0 2 ® 38 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 07/28/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07/06/2026 @ 14:19 •$80 annual inspection fee BRAD BALDWIN-07/0612026 @ 14:19 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07106/2026 @ 14:19 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07/06/2026 @ 14:19 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Kari Narey 2026 Date: _ BRAD BALDWIN 07/06/2026 CHECKLISTS GENERATED ON 7/6/26, 2:25 PM 1 OF 3 Fire Service Features Sags fr_ .= Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Comments:Install address identification numbers in contrast to the address identification.The address identification shall be building,easily visible from the road in compliance to code. legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 112 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. Portable Fire Extingusihers ccc,7 Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Extinguisher maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,last recorded Exceptions:1.The distance of travel to reach an extinguisher service complete in November 2024. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 7/6/26, 2:25 PM 2 OF 3 Fo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 7/6/26, 2:25 PM 3 OF 3