Loading...
HomeMy WebLinkAboutPAPA JOHN'S PIZZA 1608 UNIVERSITY AVE OF WA 7. INVOICE INVOICE DATE DUE DATE # TOTAL DUE 07/15/2026 08/19/2026 2027-00000014 $80.00 to • In nn nit • O 37 3S ?tl11% Customer#: 5405 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PAPA JOHN'S PIZZA 715 Mulberry St 1608 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1608 UNIVERSITY AVE STE C- FOR BILLING INQUIRY: (319)291-4323 07/14/202 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5405 07/15/2026 08/19/2026 2027-00000014 $80.00 Less Prepayment $0.00 Total Due-* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue DInspection Report 425 E.3rd Street Qy'i PAPA JOHN'S PIZZA-SUITE C-1608 University AVE,BLDG 1608 UNIVERSITY AVE, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type J Inspection Number 07/1412026 Annual Inspection(1Yr) 31 ! 23241 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION 038 07 ® 29 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/11/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07114/2026 @ 13:20 •$80 annual inspection fee BRAD BALDWIN-07/14/2026 @ 13:20 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07114/2026 @ 13:20 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Angela-2026 Date: BRAD BALDWIN 07114/2026 CHECKLISTS GENERATED ON 7/14/26, 1:38 PM 1 OF 6 General Housekeeping _,.,_ Code Description Fail 315.3.1-Ceiling clearance. Storage shall be maintained 2 feet(610 mm)or more below Location:Pizza box storage the ceiling in nonsprinklered areas of buildings or not less Comments:Lower storage of boxes to 24"below ceiling. than 18 inches(457 mm)below sprinkler head deflectors in sprinklered areas of buildings.Exceptions:1.The 2-foot(610 mm)ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings.2.The 18-inch(457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1,903.3.1.2 or 903.3.1.3. GENERATED ON 7/14/26, 1:38 PM 2 OF 6 Electrical Safety Status Code Description Fail 603.5.2-Application and usePower supply. Ox Relocatable power taps and current taps shall be directly Location:Above work desk connected to a permanently installed receptacle.Exceptions: Comments:Power strip shall plug directly to a wall outlet,currently 1.Where approved for use in a Group A occupancy or in a plugged to a multi-plug adapter meeting room inv a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Above condiment fridges(2) for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord from above drop ceiling. accordance with UL 817.Extension cords and flexible Appliances including motors or heat producing elements shall plug cordsshall not be affixed to structures,extended through directly a permanent outlet and flexible wiring shall not extend walls,ceilings or floors,or under doors or floor coverings, through concealed areas.If additional outlets installed,licensed nor shall such cords be subject to environmental damage or electrical contractor shall obtain permit and inspection. physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. 3 OF 6 GENERATED ON 7/14/28, 1:38 PM Fail 603.6-Extension cords, Extension cords and flexible cordsshall not be a substitute Location:Near back exit for permanent wiring and shall be listed and labeled in Comments:Remove extension cord from above drop ceiling.Delivery accordance with UL 817.Extension cords and flexible signs shall plug directly to a permanent outlet.If additional outlets cordsshall not be affixed to structures,extended through installed,licensed electrical contractor shall obtain permit and walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or inspection. physical impact,Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. ATM: :1. - .')4(A. . . 2.,-'- I ` -' i, ems`. \ oik Commercial Cooking Hood Suppression System Code Description Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Pizza oven suppression system appurtenances shall be inspected at intervals specified in Table or as approved by the fire code official. Comments:Contractor shall complete required inspection and Inspections 606.3.3.1 shall be completed byupload report to Compliance Engine including any deficiencies p p qualified individuals. corrected.Currently 150 days past due(see attached)for report. ProShield tagged last serviced in March 2026 Fail 606.3.3.2-Grease accumulation. If during the inspection it is found that hoods,grease-removal Location:Pizza oven suppression system devices,fans,ducts or other appurtenances have an accumulation of grease,such components shall be cleaned in Comments:Build up of grease noted on suppression lines and heads accordance with ANSIIIKECA Ci0. shall be cleaned. GENERATED ON 7/14/26, 1:38 PM 4 OF 6 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. QPortable fire extinguishers shall be selected,installed and Location:All extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service for all extinguishers,last Exceptions:1.The distance of travel to reach an extinguisher recorded service in February 2025. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. 5 OF 6 GENERATED ON 7/14/28, 1:38 PM Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number Check Number Transaction Number N/A N/A N/A GENERATED ON 7/14/26, 1:38 PM 6 OF 6