Loading...
HomeMy WebLinkAboutSOUTH HILLS GOLF COURSE 1830 E. SHAULIS RD OF WA TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE I �t 07/15/2026 08/19/2026 2027-00000019 $80.00 .,ffff4$.. /,O • 'in nmum • > T T O Customer#: 13948 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SOUTH HILLS GOLF COURSE 715 Mulberry St 1830 E SHAULIS RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1830 E. SHAULIS RD- FOR BILLING INQUIRY: (319)291-4323 07/07/2026 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13948 07/15/2026 08/19/2026 2027-00000019 $80.00 Less Prepayment _ $0.00 Total Due-+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue t k Inspection Report 425E.3rd Street <,k South Hills Golf Course-1830 E Shaulis RD,BLDG 1830 E Shaulis Rd,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type �� Inspection Number 07/07/2026 Annual Inspection(1Yr) _ 13 q� j �V,� 16531 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 030 07 ® 38 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/03/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07107/2026 @ 13:50 •S80 annual inspection fee BRAD BALDWIN-0710712026 @ 13:50 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/0712026 @ 13:50 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and S200 for all subsequent re-inspections. BRAD BALDWIN-07107/2026 @ 13:50 Inspector did not gain access to north parking lot accessory building during 7/7126 inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection JB Date: BRAD BALDWIN 07/09/2026 CHECKLISTS GENERATED ON 7/9/26, 2:29 PM 1. OF 6 Additional Codes Code Description Fail 1010.2.4-Locks and latches. Locks and latches shall be permitted to prevent operation of Location:Banquet room doors where any of the following exist:1.Places of detention Comments:Permanent approved signage shall be installed to(east) or restraint.2.In Group I-1,Condition 2 and Group 1-2 exit door stating,"THIS DOOR SHALL REMAIN UNLOCKED DURING occupancies where the clinical needs of persons receiving BUSINESS HOURS" care require containment or where persons receiving care pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 7/9/26, 2:29 PM 2 OF 6 Fail 5807.2.1-Securing containers. Containers,cylinders and tanks shall be secured in Location:Office accordance with Section 5303.5.3. Comments:Secure compressed gas cylinders with chain to avoid tip over. General Housekeeping Stan.: Ccds Description Fail 305.1-Clearance from ignition sources. Clearance between ignition sources,such as luminaires, Location:Water heater heaters,flame-producing devices and combustible materials, Comments:Remove storage within 36"of appliance.Maintain proper shall be maintained in an approved manner. clearances at all times Fire Service Features _- Cod2 Description Fail 505.1-Address identification. New and existing buildings shall be provided with approved Location:Front of building address identification.The address identification shall be Comments:Permanent address identification numbers shall be legible and placed in a position that is visible from the street installed in contrast with the building visible from the road to comply or road fronting the property.Address identification with code standards. characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm).Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. GENERATED ON 7/9/26, 2:29 PM 3 OF 6 Electrical Safety S;<o,s Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Golf cart building prohibited.Approved covers shall be provided for all switch Comments:Provide cover to box on ceiling to avoid open wire and electrical outlet boxes. connections. r i t M R �i ice, GENERATED ON 7/9/26, 2:29 PM 4 OF 6 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Electrical room-Pro Shop equipment shall be provided in accordance with Section Comments:Remove storage within 36"of electrical panels.Maintain 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or proper clearances at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). JJ pM L art. E 1 t Ni fear Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Electrical room-Pro Shop with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide approved permanent signage on door to electric ROOM"or similar approved wording.The disconnecting panels.Laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. GENERATED ON 7/9/26, 2:29 PM 5 OF 6 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number N/A NIA NIA • • GENERATED ON 2/9/26,2:29 RN 6 OF 6