HomeMy WebLinkAboutWATERLOO WOMENS CENTER FOR CHANGE 1515 LAFAYETTE ST OF WA�, INVOICE DATE DUE DATE INVOICE# TOTAL DUE
07/15/2026 08/19/2026 2027-00000022 $100.00
o/
u ..a..... /�o
• • II 1111 II •
T-__T 0
4S 1;17'�
Customer#: 21445 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
WATERLOO WOMENS CENTER FOR CHANGE 715 Mulberry St
1515 LAFAYETTE ST WATERLOO, IA 50703
WATERLOO, IA 50703
Amount Enclosed.
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 1515 LAFAYETTE ST- I
01/06/2026 FOR BILLING INQUIRY: (319)291-4323
IDescription
Total Price I
INSPECTION 2,000 HH
OCCUPANCY FEE $90.00
$10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
21445 07/15/2026 08/19/2026 2027-00000022 $100.00_
Less Prepayment $0.00
Total Due--> $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
425 E.3rd Street
Women's Center for Change-1515 Lafayette ST,BLDG 1515 Lafayette,Waterloo IA
50703
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
01/06/2026 Annual Inspection(1Yr) 144i _ 4 ' p 00 15808
Lead Inspector Shift Station Unit
JEREMIAH VANDYKE NIA Station 1 Fire NIA
Headquarters
Other Inspectors
NIA
SUMMARY OF INSPECTION
0 61 2 ® 10
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
JEREMIAH VANDYKE 02/05/2026
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE-01/06/2026 @ 13:38
Fire extinguishers serviced by Proshield Jan 2026.
JEREMIAH VANDYKE-01/06/2026 @ 13:39
Clothes dryers vents cleaned in house and recorded 7/25/2025.
JEREMIAH VANDYKE-01/06/2026 @ 13:39
Load bank and Generator testing completed 913/2025 by Pioneer Electric
JEREMIAH VANDYKE-01/0612026 @ 13:39
Re-inspection dates are automatically generated 30 days out from the initial inspection.Normal operating hours for inspections&re-inspections are
Monday-Friday,8:00 am.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed
the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.****"Re inspection fees
may be assessed for subsequent re-inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-01/06/2026 @ 13:40
Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-1615
JEREMIAH VANDYKE-0110612026 @ 13:40
Inspection Fee=$100.00(To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 1/6/26,1:41 PM 1 OF 3
Blake Burton Date:
CHECKLISTS
Fire Service Features
S�a�us Code
Description
/
Fail 509.1-Identification.
Fire protection equipment shall be identified in an approved Location:Roof Access sign needed on 2 doors.
manner.Rooms containing controls for air-conditioning
systems,sprinkler risers and valves,or other fire detection, Comments:Send picture to my email or cell after signs placed.
suppression or control elements fire protection systems shall
be identified for the use of the fire department..Approved
signs required to identify fire protection system equipment
and equipment location shall be constructed of durable
materials,permanently installed and readily visible.
Commercial Cooking Hood Suppression System
S[at,s Ccde Description
Fail 606.33.3-Records.
Records for inspections shall state the individual and Location:Hood cleaning report us 161 days past due according to
company performing the inspection,a description of the Compliance engine.
inspection and when the inspection took place.Records for
Comments:Contact contractor to upload hood cleaning report to
cleanings shall state the individual and company performing
Compliance engine.
the cleaning and when the cleaning took place.Such records
shall be completed after each inspection or cleaning and
maintained.
GENERATED ON 1/6/26,1:41 PM
2 OF 3
O Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
N/A S100.00
Invoice Number Check Number Transaction Number
N/A NIA NIA
GENERATED ON 1/6/26,1:41 PM 3 OF 3
W p 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE
O
:1)( 07/15/2026 08/19/2026 2027-00000006 $80.00
41/4
v.,ricer..•.
o
• II I.II II II I •
> T-=T 0
Customer#: 10511 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
HIGHWAY 63 DINER 715 Mulberry St
3030 MARNIE AV WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION- 3030 MARNIE AVE-07/06/2026 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
10511 07/15/2026 08/19/2026 2027-00000006 $80.00
Less Prepayment $0.00
Total Due-+ $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
€)W
Waterloo Fire Rescue
Inspection Report 425 E.3rd Street
Highway 63 Diner-3030 Marnie AVE,BLDG 3030 Marnie Ave,Waterloo IA 50701
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
07/06/2026 - Annual Inspection(1Yr) 10511 31 CO 23014
Lead Inspector Shift Station Unit
BRAD BALDWIN N/A NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
e 42 � 4 ® 29
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
07/28/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-0710612026 @ 12:35
•$80 annual inspection fee
BRAD BALDWIN-07/06/2026 @ 12:36
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-07/06/2026 @ 12:36
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-07106/2026 @ 12:36
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
BRAD BALDWIN-07106/2026 @ 12:46
Clothes dryer vent cleaning completed 2/2/26 by Harris Cleaning.Annual cleaning(minimum interval of cleaning)shall be maintained.
SIGNATURES
Contact signature Inspector signature
No signature
Report completededpost stinspection 11
Jeani Johnson Date: BRAD BALDWIN 07106/2026
CHECKLISTS
GENERATED ON 7/6/26, 12:48 PM 1 OF 3
Emergency Equipment
status Code Desolation
Fail 1203,2.15-Means of egress illumination.
Emergency power shall be provided for means of egress Location:Front hostess stand.
illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate
during test.
Fail 1203.2.15-Means of egress illumination.
Emergency power shall be provided for means of egress Location:Bar-above POS system computer
illumination in accordance with Sections 1008,3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate
during test.
Additional Codes
Status Cade Desedeetion
Fail 606.3.1-Ventilation system.
The ventilation system in connection with hoods shall be Location:Kitchen hood exhaust
operated at the required rate of air movement,and grease Comments:Replace damaged filters(2)and close any gaps in filters.
filters listed and labeled in accordance with UL 1046 shall be Filters not in place cause more grease in ductwork and on cables for
in place where equipment under a kitchen grease hood is fire suppression
used.
Fire Resistant Construction Maintenance
Status Code Description
Fail 704.1-Maintaining protection.
Where required when the building was originally constructed, Location:Servers area
materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles.
following locations shall be maintained.The materials and
systems shall be securely attached to or bonded to the
adjacent construction,without openings visible through the
construction.1.Joints in or between fire-resistance-rated
walls,floors or floor/ceiling assemblies and roof or
rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall.4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall.S.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall.6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall.7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly.Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed.Where the system design number is known,the
system shall be inspected to the listing criteria and
manufacturer&x039;s installation instructions.
GENERATED ON 7/6/26, 12:46 PH 2 OF 2
El Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $80.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 7/6/26, 12:48 PM 3 OF 3